CoChat

Artificial Intelligence for Skin Cancer Detection: Scoping Review

Open access
Takiddin, Abdulrahman, Schneider, Jens, Yang, Yin, Abd-Alrazaq, Alaa, Househ, Mowafa · 2021 · Journal of Medical Internet Research
Cited by 72

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Skin cancer is the most common cancer type affecting humans. Traditional skin cancer diagnosis methods are costly, require a professional physician, and take time. Hence, to aid in diagnosing skin cancer, artificial intelligence (AI) tools are being used, including shallow and deep machine learning–based methodologies that are trained to detect and classify skin cancer using computer algorithms and deep neural networks. Objective: The aim of this study was to identify and group the different types of AI-based technologies used to detect and classify skin cancer. The study also examined the reliability of the selected papers by studying the correlation between the data set size and the number of diagnostic classes with the performance metrics used to evaluate the models. Methods: We conducted a systematic search for papers using Institute of Electrical and Electronics Engineers (IEEE) Xplore, Association for Computing Machinery Digital Library (ACM DL), and Ovid MEDLINE databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) guidelines. The studies included in this scoping review had to fulfill several selection criteria: being specifically about skin cancer, detecting or classifying skin cancer, and using AI technologies. Study selection and data extraction were independently conducted by two reviewers. Extracted data were narratively synthesized, where studies were grouped based on the diagnostic AI techniques and their evaluation metrics. Results: We retrieved 906 papers from the 3 databases, of which 53 were eligible for this review. Shallow AI-based techniques were used in 14 studies, and deep AI-based techniques were used in 39 studies. The studies used up to 11 evaluation metrics to assess the proposed models, where 39 studies used accuracy as the primary evaluation metric. Overall, studies that used smaller data sets reported higher accuracy. Conclusions: This paper examined multiple AI-based skin cancer detection models. However, a direct comparison between methods was hindered by the varied use of different evaluation metrics and image types. Performance scores were affected by factors such as data set size, number of diagnostic classes, and techniques. Hence, the reliability of shallow and deep models with higher accuracy scores was questionable since they were trained and tested on relatively small data sets of a few diagnostic classes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/22934

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 72

Metadata

Authors
Takiddin, A., Schneider, J., Yang, Y., Abd-Alrazaq, A., & Househ, M.
Venue
Journal of Medical Internet Research
Published
2021-11-24
Volume
23
Issue
11
Pages
e22934
ISSN
1438-8871 (ISSN-L)
OpenAlex
W3192208986
Cited by
72
References
1
FWCI
3.67
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence for Skin Cancer Detection: Scoping Review. https://app.cochat.ai/papers/10.2196/22934
The paper
Takiddin, A., Schneider, J., Yang, Y., Abd-Alrazaq, A., & Househ, M. (2021). Artificial Intelligence for Skin Cancer Detection: Scoping Review. Journal of Medical Internet Research. https://doi.org/10.2196/22934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.