Use of Physiological Data From a Wearable Device to Identify SARS-CoV-2 Infection and Symptoms and Predict COVID-19 Diagnosis: Observational Study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Changes in autonomic nervous system function, characterized by heart rate variability (HRV), have been associated with infection and observed prior to its clinical identification. Objective: We performed an evaluation of HRV collected by a wearable device to identify and predict COVID-19 and its related symptoms. Methods: Health care workers in the Mount Sinai Health System were prospectively followed in an ongoing observational study using the custom Warrior Watch Study app, which was downloaded to their smartphones. Participants wore an Apple Watch for the duration of the study, measuring HRV throughout the follow-up period. Surveys assessing infection and symptom-related questions were obtained daily. Results: Using a mixed-effect cosinor model, the mean amplitude of the circadian pattern of the standard deviation of the interbeat interval of normal sinus beats (SDNN), an HRV metric, differed between subjects with and without COVID-19 (P=.006). The mean amplitude of this circadian pattern differed between individuals during the 7 days before and the 7 days after a COVID-19 diagnosis compared to this metric during uninfected time periods (P=.01). Significant changes in the mean and amplitude of the circadian pattern of the SDNN was observed between the first day of reporting a COVID-19–related symptom compared to all other symptom-free days (P=.01). Conclusions: Longitudinally collected HRV metrics from a commonly worn commercial wearable device (Apple Watch) can predict the diagnosis of COVID-19 and identify COVID-19–related symptoms. Prior to the diagnosis of COVID-19 by nasal swab polymerase chain reaction testing, significant changes in HRV were observed, demonstrating the predictive ability of this metric to identify COVID-19 infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Feasibility of controlling COVID-19 outbreaks by isolation of cases and contacts
Hellewell, J., Abbott, S., Gimma, A., Bosse, N. I., Jarvis, C. I., Russell, T. W., Munday, J. D., Kucharski, A. J., Edmunds, W. J., Sun, F., et al. (2020) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30074-7 · Cited by 2,550
Real-time tracking of self-reported symptoms to predict potential COVID-19
Menni, C., Valdes, A. M., Freidin, M. B., Sudre, C. H., Nguyen, L. H., Drew, D. A., Ganesh, S., Varsavsky, T., Cardoso, M. J., El-Sayed Moustafa, J. S., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0916-2 · Cited by 1,517 · cited 1×
“Smartphone apps are effective in using symptoms to identify people who may be infected with SARS-CoV-2; however, these apps rely on ongoing participant compliance and self-reported symptoms [8].”
Applications of digital technology in COVID-19 pandemic planning and response
Whitelaw, S., Mamas, M. A., Topol, E., & Van Spall, H. G. C. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30142-4 · Cited by 992 · cited 2×
“Digital health technology offers an opportunity to address the limitations of traditional public health strategies aimed at curbing the spread of COVID-19 [7].”
Wearable sensor data and self-reported symptoms for COVID-19 detection
Quer, G., Radin, J. M., Gadaleta, M., Baca-Motes, K., Ariniello, L., Ramos, E., Kheterpal, V., Topol, E. J., & Steinhubl, S. R. (2021) · Nature Medicine · doi:10.1038/s41591-020-1123-x · Cited by 447 · cited 2×
“This concept was recently expanded during the COVID-19 pandemic by Quer and colleagues [10], who demonstrated that the combination of symptom-based data with resting heart rate and sleep data from wearable devices was superior to relying on symptom-based data alone to identify COVID-19 infections.”
Radin, J. M., Wineinger, N. E., Topol, E. J., & Steinhubl, S. R. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30222-5 · Cited by 300
Ahmad, S., Tejuja, A., Newman, K. D., Zarychanski, R., & Seely, A. J. (2009) · Critical Care · doi:10.1186/cc8132 · Cited by 151
Cited by
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
“In 2022, an estimated 67 million people were projected to use a wearable device in the US; 50% of consumers were interested in tracking their cardiac health, and 68% of physicians intended to use a wearable device for patient monitoring [27].”
BackgroundHolko, M., Litwin, T. R., Munoz, F., Theisz, K. I., Salgin, L., Jenks, N. P., Holmes, B. W., Watson-McGee, P., Winford, E., & Sharma, Y. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00593-x · Cited by 85
Utilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach
Kasl, P., Keeler Bruce, L., Hartogensis, W., Dasgupta, S., Pandya, L. S., Dilchert, S., Hecht, F. M., Gupta, A., Altintas, I., Mason, A. E., et al. (2024) · Sensors · doi:10.3390/s24061818 · Cited by 13
“Other efforts have engineered more complicated features, i.e., features based on deviations from expected circadian rhythms [36]; here, we demonstrate an impressive performance using nightly summary data.”
Background
Metadata
- Authors
- Hirten, R. P., Danieletto, M., Tomalin, L., Choi, K. H., Zweig, M., Golden, E., Kaur, S., Helmus, D., Biello, A., Pyzik, R., Charney, A., Miotto, R., Glicksberg, B. S., Levin, M., Nabeel, I., Aberg, J., Reich, D., Charney, D., Bottinger, E. P., Keefer, L., Suarez-Farinas, M., Nadkarni, G. N., & Fayad, Z. A.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2021-02-22
- Volume
- 23
- Issue
- 2
- Pages
- e26107
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W3128377640
- Cited by
- 160
- References
- 7
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Physiological Data From a Wearable Device to Identify SARS-CoV-2 Infection and Symptoms and Predict COVID-19 Diagnosis: Observational Study. https://app.cochat.ai/papers/10.2196/26107
- The paper
- Hirten, R. P., Danieletto, M., Tomalin, L., Choi, K. H., Zweig, M., Golden, E., Kaur, S., Helmus, D., Biello, A., Pyzik, R., Charney, A., Miotto, R., Glicksberg, B. S., Levin, M., Nabeel, I., Aberg, J., Reich, D., Charney, D., Bottinger, E. P., . . . Fayad, Z. A. (2021). Use of Physiological Data From a Wearable Device to Identify SARS-CoV-2 Infection and Symptoms and Predict COVID-19 Diagnosis: Observational Study. Journal of Medical Internet Research. https://doi.org/10.2196/26107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.