The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Efficacy of the Dyson Air Purifier in Improving Asthma Control: Protocol for a Single-Center, Investigator-Led, Randomized, Double-Blind, Placebo-Controlled Trial
Open accessPublished version of a preprint
Abstract
Background: Indoor air quality has been shown to influence asthma control and outcomes. Air purifiers and high-efficiency particulate air filtration devices can improve indoor air quality by reducing the indoor levels of air pollution and allergens. However, the influence of this improved indoor air quality on asthma control remains unclear; hence, randomized controlled trials are needed to further elucidate this phenomenon. Objective: This study aims to investigate the effect of reducing the levels of allergens and pollutants in the bedroom and living room through the use of Dyson air purifiers (Dyson Pure Cool) on asthma control. Methods: This is an 18-month long, investigator-led, randomized, double-blinded, placebo-controlled, single-center trial. Subjects will be randomized in a 1:1 ratio to active or placebo Dyson filters. The primary outcome is the change in the scores of Asthma Control Questionnaire 6 and Asthma-specific Quality of Life Questionnaire from baseline. Secondary outcomes include changes in lung function (forced expiratory volume in one second, forced expiratory volume in one second/forced vital capacity ratio, and midexpiratory flows), peak expiratory flow measurements, airway hyperresponsiveness (assessed by methacholine bronchial challenge), fractional exhaled nitric oxide, and indoor air pollutant levels. The sample size will be 50 subjects, and all subjects will have a confirmed diagnosis of mild persistent to moderate persistent asthma along with an Asthma Control Questionnaire 6 score of >1.5. Results: This study was approved by the West Midlands Research Ethics Committee (18/WM/0277). The study results will be published in peer-reviewed scientific journals; presented at relevant scientific conferences; and shared in plain English with participants in our newsletters, in our clinics, and via the David Hide Asthma and Allergy Research Centre website. Our trial began in September 2019 and is expected to end in August 2021. Conclusions: This is a double-blinded, placebo-controlled, randomized, investigator-led study to investigate the efficacy of a novel air purifier in improving asthma control in adults. The trial period of 18 months will facilitate the collection of robust data and will therefore generate clear signals. However, this extended trial duration may lead to patient withdrawal. Furthermore, this trial is conducted at a single center and in a location with a homogenous cohort of people, which may affect translatability. Nonetheless, it is hoped that the findings of this trial may help further inform clinicians regarding the utility of this novel device as an adjunct in asthma care. Trial Registration: ClinicalTrials.gov NCT04729530; https://clinicaltrials.gov/ct2/show/NCT04729530 International Registered Report Identifier (IRRID): DERR1-10.2196/28624
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
the CONSORT Group, Schulz, K. F., Altman, D. G., & Moher, D. (2010) · Trials · doi:10.1186/1745-6215-11-32 · Cited by 1,871
Flagged first, then by citations
Research works printed but not linked: 30
- 10.1056/NEJMra054308 · DOI · Paper page
- 10.1007/s11882-003-0023-8 · DOI
- 10.1513/pats.200908-083rm · DOI
- 10.4103/0019-5278.32461 · DOI
- 10.1038/jes.2014.21 · DOI
- 10.1164/ajrccm.157.6.9603034 · DOI
- 10.1007/s11882-009-0082-6 · DOI
- 10.1007/s11882-001-0076-5 · DOI
- 10.1016/j.jaci.2017.04.024 · DOI
- 10.1067/mai.2000.104552 · DOI
- 10.1164/rccm.201305-0889OC · DOI
- 10.1164/ajrccm.149.6.8004290 · DOI
- 10.1111/ina.12085 · DOI
- 10.1001/archpediatrics.2011.111 · DOI
- 10.1542/peds.2009-2312 · DOI
- 10.1046/j.1365-2222.2003.01570.x · DOI
- 10.1136/thoraxjnl-2011-200665 · DOI
- 10.1136/bmjresp-2015-000117 · DOI
- 10.3310/hta23290 · DOI
- 10.1034/j.1399-3003.1999.14d29.x · DOI · Paper page
- 10.1378/chest.115.5.1265 · DOI
- 10.1164/rccm.201908-1590ST · DOI · Paper page
- 10.1164/ajrccm.156.3.9701113 · DOI
- 10.1183/13993003.01526-2016 · DOI
- 10.1093/ije/dyy023 · DOI
- 10.1164/ajrccm.160.6.ats8-99 · DOI
- 10.1016/s0091-6749(99)70380-5 · DOI
- 10.1183/09031936.95.08030483 · DOI · Paper page
- 10.1186/2045-7022-3-3 · DOI
- 10.7326/0003-4819-158-3-201302050-00583 · DOI · Paper page
Metadata
- Authors
- Fong, W. C. G., Grevatt, S., Potter, S., Tidbury, T., Kadalayil, L., Bennett, K., Larsson, M., Nicolas, F., Kurukulaaratchy, R., & Arshad, S. H.
- Affiliations
- David Hide Asthma and Allergy Research Centre (GB)
- Dyson (United Kingdom) (GB)
- Corresponding author
- Arshad, Syed Hasan
- ORCID
- Venue
- JMIR Research Protocols
- Publisher
- JMIR Publications Inc.
- Published
- 2021-07-27
- Volume
- 10
- Issue
- 7
- Pages
- e28624
- ISSN
- 1929-0748 (ISSN-L)
- PMC
- PMC8367098
- OpenAlex
- W3183974278
- Cited by
- 5
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 1
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR Research Protocols (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (acceptedVersion)
- ePrints Soton (University of Southampton) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
- Keywords
- asthma control, air purifiers, indoor air quality, allergens, indoor air pollutants, Asthma Control Questionnaire, asthma-specific quality of life, lung function, airway hyperresponsiveness, methacholine challenge, exhaled nitric oxide, adult asthma, trial limitations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review