Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Background: Numerous wrist-wearable devices to measure physical activity are currently available, but there is a need to unify the evidence on how they compare in terms of acceptability and accuracy. Objective: The aim of this study is to perform a systematic review of the literature to assess the accuracy and acceptability (willingness to use the device for the task it is designed to support) of wrist-wearable activity trackers. Methods: We searched MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, and SPORTDiscus for studies measuring physical activity in the general population using wrist-wearable activity trackers. We screened articles for inclusion and, for the included studies, reported data on the studies’ setting and population, outcome measured, and risk of bias. Results: A total of 65 articles were included in our review. Accuracy was assessed for 14 different outcomes, which can be classified in the following categories: count of specific activities (including step counts), time spent being active, intensity of physical activity (including energy expenditure), heart rate, distance, and speed. Substantial clinical heterogeneity did not allow us to perform a meta-analysis of the results. The outcomes assessed most frequently were step counts, heart rate, and energy expenditure. For step counts, the Fitbit Charge (or the Fitbit Charge HR) had a mean absolute percentage error (MAPE) <25% across 20 studies. For heart rate, the Apple Watch had a MAPE <10% in 2 studies. For energy expenditure, the MAPE was >30% for all the brands, showing poor accuracy across devices. Acceptability was most frequently measured through data availability and wearing time. Data availability was ≥75% for the Fitbit Charge HR, Fitbit Flex 2, and Garmin Vivofit. The wearing time was 89% for both the GENEActiv and Nike FuelBand. Conclusions: The Fitbit Charge and Fitbit Charge HR were consistently shown to have a good accuracy for step counts and the Apple Watch for measuring heart rate. None of the tested devices proved to be accurate in measuring energy expenditure. Efforts should be made to reduce the heterogeneity among studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Sekhon, M., Cartwright, M., & Francis, J. J. (2017) · BMC Health Services Research · doi:10.1186/s12913-017-2031-8 · Cited by 3,938
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · cited 3×
“Feehan et al [77] conducted a systematic review on the accuracy of Fitbit devices for measuring physical activity.”
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 1×
“For the Jawbone UP , the MAPE was –6.73% in a study [65] and the mean absolute difference 806 over an average of 9959 steps in another study [29].”
InfluentialVariable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · cited 3×
“For the Fitbit Charge , the mean difference was –59 (SD 704) steps compared with direct observation [64].”
Shin, G., Jarrahi, M. H., Fei, Y., Karami, A., Gafinowitz, N., Byun, A., & Lu, X. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103153 · Cited by 326 · cited 3×
“The data extraction form was based on a previous publication on the same topic [8] and adapted to the needs of this review.”
InfluentialNaslund, J. A., Aschbrenner, K. A., Barre, L. K., & Bartels, S. J. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0105 · Cited by 144 · cited 1×
“%) over 80-133 days [73].”
Cited by
Doherty, C., Baldwin, M., Keogh, A., Caulfield, B., & Argent, R. (2024) · Sports Medicine · doi:10.1007/s40279-024-02077-2 · Cited by 133
“Four systematic reviews (none of which included meta-analysis), one deemed to be of moderate quality and three of low quality, assessed the validity of wearables for measuring physical activity intensity [37, 38, 40, 43].”
InfluentialHaresamudram, H., Tang, C. I., Suh, S., Lukowicz, P., & Plötz, T. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3729467 · Cited by 33
Haresamudram, H., Tang, C. I., Suh, S., Lukowicz, P., & Ploetz, T. (2024) · arXiv · Cited by 31
Metadata
- Authors
- Germini, F., Noronha, N., Borg Debono, V., Abraham Philip, B., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2022-01-21
- Volume
- 24
- Issue
- 1
- Pages
- e30791
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W4205192005
- Cited by
- 220
- References
- 18
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.