Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
Abstract
PURPOSE: Athletes and members of the public increasingly rely on wearable HR monitors to guide physical activity and training. The accuracy of newer, optically based monitors is unconfirmed. We sought to assess the accuracy of five optically based HR monitors during various types of aerobic exercise. METHODS: Fifty healthy adult volunteers (mean ± SD age = 38 ± 12 yr, 54% female) completed exercise protocols on a treadmill, a stationary bicycle, and an elliptical trainer (±arm movement). Each participant underwent HR monitoring with an electrocardiogaphic chest strap monitor (Polar H7), forearm monitor (Scosche Rhythm+), and two randomly assigned wrist-worn HR monitors (Apple Watch, Fitbit Blaze, Garmin Forerunner 235, and TomTom Spark Cardio), one on each wrist. For each exercise type, HR was recorded at rest, light, moderate, and vigorous intensity. Agreement between HR measurements was assessed using Lin's concordance correlation coefficient (rc). RESULTS: Across all exercise conditions, the chest strap monitor (Polar H7) had the best agreement with ECG (rc = 0.996) followed by the Apple Watch (rc = 0.92), the TomTom Spark (rc = 0.83), and the Garmin Forerunner (rc = 0.81). Scosche Rhythm+ and Fitbit Blaze were less accurate (rc = 0.75 and rc = 0.67, respectively). On treadmill, all devices performed well (rc = 0.88-0.93) except the Fitbit Blaze (rc = 0.76). While bicycling, only the Garmin, Apple Watch, and Scosche Rhythm+ had acceptable agreement (rc > 0.80). On the elliptical trainer without arm levers, only the Apple Watch was accurate (rc = 0.94). None of the devices was accurate during elliptical trainer use with arm levers (all rc < 0.80). CONCLUSION: The accuracy of wearable, optically based HR monitors varies with exercise type and is greatest on the treadmill and lowest on elliptical trainer. Electrode-containing chest monitors should be used when accurate HR measurement is imperative.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other studies have used suboptimal reference methods, such as chest straps or pulse oximeters, which themselves have a degree of error varying between 0 and 40 bpm when compared to electrocardiograms.
“other studies have used suboptimal reference methods, such as the chest straps45–47 or pulse oximeters48, which themselves have a degree of error (varying between 0 and 40 bpm when compared to ECGs44).”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [46]
Motion artifacts and level of physical activity are two related factors identified as influencing wearable heart rate accuracy.
“two related factors identified as influencing wearable HR accuracy are motion artifacts23 and level of physical activity46.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [46]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · see citing works
Wearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808 · see citing works
Swan, M. (2009) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph6020492 · Cited by 730 · see citing works
Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694 · see citing works
Fitbit®: An accurate and reliable device for wireless physical activity tracking
Diaz, K. M., Krupka, D. J., Chang, M. J., Peacock, J., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.038 · Cited by 405 · see citing works
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · see citing works
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Self-citationEl-Amrawy, F., & Nounou, M. I. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.315 · Cited by 287 · see citing works
Heart rate monitors: State of the art
Laukkanen, R. M. T., & Virtanen, P. K. (1998) · Journal of Sports Sciences · doi:10.1080/026404198366920 · Cited by 219 · see citing works
Heart Rate Monitors: Validity, Stability, and Functionality
Léger, L., & Thivierge, M. (1988) · The Physician and Sportsmedicine · doi:10.1080/00913847.1988.11709511 · Cited by 210 · see citing works
Murakami, H., Kawakami, R., Nakae, S., Nakata, Y., Ishikawa-Takata, K., Tanaka, S., & Miyachi, M. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2016.0152 · Cited by 204 · see citing works
Validity of Seven Commercially Available Heart Rate Monitors
Terbizan, D. J., Dolezal, B. A., & Albano, C. B. (2002) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0604_3 · Cited by 147 · see citing works
Alzahrani, A., Hu, S., Azorin-Peris, V., Barrett, L. A., Esliger, D., Hayes, M., Akbare, S., Achart, J., & Kuoch, S. (2015) · Sensors · doi:10.3390/s151025681 · Cited by 56 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Mountjoy, M., Ackerman, K. E., Bailey, D. M., Burke, L. M., Constantini, N., Hackney, A. C., Heikura, I. A., Melin, A., Pensgaard, A. M., Stellingwerff, T., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-106994 · Cited by 724 · see citing works
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542 · see citing works
Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446 · see citing works
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 378 · see citing works
Shin, G., Jarrahi, M. H., Fei, Y., Karami, A., Gafinowitz, N., Byun, A., & Lu, X. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103153 · Cited by 326 · see citing works
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310 · see citing works
Personal thermal comfort models with wearable sensors
Liu, S., Schiavon, S., Das, H., Jin, M., & Spanos, C. J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106281 · Cited by 308 · see citing works
Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272 · see citing works
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261 · see citing works
Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research
Nelson, B. W., Low, C. A., Jacobson, N., Areán, P., Torous, J., & Allen, N. B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0297-4 · Cited by 241 · see citing works
Recent advances and perspectives in sweat based wearable electrochemical sensors
Mohan, A. M. V., Rajendran, V., Mishra, R. K., & Mathiyarasu, J. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116024 · Cited by 234 · see citing works
Germini, F., Noronha, N., Debono, V. B., Philip, B. A., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A. (2021) · Journal of Medical Internet Research · doi:10.2196/30791 · Cited by 222 · see citing works
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001471 · Cited by 205 · see citing works
Current State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194 · see citing works
Blum, J., Rockstroh, C., & Göritz, A. S. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02172 · Cited by 183 · see citing works
Wearable activity trackers–advanced technology or advanced marketing?
Shei, R., Holder, I. G., Oumsang, A. S., Paris, B. A., & Paris, H. L. R. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04951-1 · Cited by 169 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Falter, M., Budts, W., Goetschalckx, K., Cornelissen, V., & Buys, R. (2019) · JMIR mHealth and uHealth · doi:10.2196/11889 · Cited by 142 · see citing works
Assessment of the Fitbit Charge 2 for monitoring heart rate
Benedetto, S., Caldato, C., Bazzan, E., Greenwood, D. C., Pensabene, V., & Actis, P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192691 · Cited by 149 · see citing works
Accuracy of wearable heart rate monitors in cardiac rehabilitation
Etiwy, M., Akhrass, Z., Gillinov, L., Alashi, A., Wang, R., Blackburn, G., Gillinov, S. M., Phelan, D., Gillinov, A. M., Houghtaling, P. L., et al. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.04.08 · Cited by 143 · see citing works
Self-citationChow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140 · see citing works
“Moreover, potential variables such as age, ethnicity, and gender were not considered in earlier studies [2,14].”
InfluentialAccuracy of commercially available heart rate monitors in athletes: a prospective study
Pasadyn, S. R., Soudan, M., Gillinov, M., Houghtaling, P., Phelan, D., Gillinov, N., Bittel, B., & Desai, M. Y. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.06.05 · Cited by 135 · see citing works
Self-citationSoon, S., Svavarsdottir, H. S., Downey, C. L., & Jayne, D. G. (2020) · BMJ Innovations · doi:10.1136/bmjinnov-2019-000354 · Cited by 133 · see citing works
Hettiarachchi, I. T., Hanoun, S., Nahavandi, D., & Nahavandi, S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217288 · Cited by 121 · see citing works
Review of Validity and Reliability of Garmin Activity Trackers
Evenson, K. R., & Spade, C. L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0035 · Cited by 117 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
The Emerging Role of Wearable Technologies in Detection of Arrhythmia
Cheung, C. C., Krahn, A. D., & Andrade, J. G. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.05.003 · Cited by 114 · see citing works
Practices and Applications of Heart Rate Variability Monitoring in Endurance Athletes
Lundstrom, C. J., Foreman, N. A., & Biltz, G. R. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1864-9726 · Cited by 122 · see citing works
Advanced Wearable Medical Devices and Their Role in Transformative Remote Health Monitoring
Tariq, M. U. (2024) · Advances in healthcare information systems and administration book series · doi:10.4018/979-8-3693-3661-8.ch015 · Cited by 109 · see citing works
Nielsen, J. C., Lin, Y., Figueiredo, M. J. D. O., Shamloo, A. S., Alfie, A., Bovéda, S., Dagres, N., Toro, D. D., Eckhardt, L. L., Ellenbogen, K. A., et al. (2020) · Journal of Arrhythmia · doi:10.1002/joa3.12338 · Cited by 102 · see citing works
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98 · see citing works
Stretchable PPG sensor with light polarization for physical activity–permissible monitoring
Lee, G. H., Kang, H., Chung, J. W., Lee, Y., Yoo, H., Jeong, S., Cho, H. K., Kim, J., Kang, S., Jung, J. Y., et al. (2022) · Science Advances · doi:10.1126/sciadv.abm3622 · Cited by 95 · see citing works
Consumer Wearable Health and Fitness Technology in Cardiovascular Medicine
Petek, B. J., Al‐Alusi, M. A., Moulson, N., Grant, A. J., Besson, C., Guseh, J. S., Wasfy, M. M., Grémeaux, V., Churchill, T. W., & Baggish, A. L. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.054 · Cited by 106 · see citing works
Lam, C. K. C., Hang, J., Zhang, D., Wang, Q., Ren, M., & Huang, C. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107877 · Cited by 90 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Kazanskiy, N. L., Butt, M. A., & Khonina, S. N. (2022) · Nanomaterials · doi:10.3390/nano12030334 · Cited by 87 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
Chevance, G., Golaszewski, N. M., Tipton, E., Hekler, E. B., Buman, M. P., Welk, G. J., Patrick, K., & Godino, J. (2022) · JMIR mhealth and uhealth · doi:10.2196/35626 · Cited by 77 · see citing works
Wearable Sensors to Monitor, Enable Feedback, and Measure Outcomes of Activity and Practice
Dobkin, B. H., & Martinez, C. A. (2018) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-018-0896-5 · Cited by 76 · see citing works
Borland, R. L., Cameron, L. A., Tonge, B. J., & Gray, K. M. (2021) · Journal of Applied Research in Intellectual Disabilities · doi:10.1111/jar.12961 · Cited by 76 · see citing works
Gao, Y., Mohammadifar, M., & Choi, S. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900079 · Cited by 67 · see citing works
Comprehensive comparison of Apple Watch and Fitbit monitors in a free-living setting
Bai, Y., Tompkins, C. L., Gell, N., Dione, D. R., Zhang, T., & Byun, W. (2021) · PLoS ONE · doi:10.1371/journal.pone.0251975 · Cited by 67 · see citing works
Sartor, F., Gelissen, J., van Dinther, R., Roovers, D., Papini, G. B., & Coppola, G. (2018) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-018-0098-0 · Cited by 65 · see citing works
Increasing and Evolving Role of Smart Devices in Modern Medicine
Massoomi, M. R., & Handberg, E. M. (2019) · European Cardiology Review · doi:10.15420/ecr.2019.02 · Cited by 64 · see citing works
Concurrent heart rate validity of wearable technology devices during trail running
Navalta, J. W., Montes, J., Bodell, N. G., Salatto, R. W., Manning, J. W., & DeBeliso, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238569 · Cited by 62 · see citing works
Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59 · see citing works
Müller, A. M., Wang, N. X., Yao, J., Tan, C. S., Low, I. C. C., Lim, N., Tan, J., Tan, A. W. H., & Müller‐Riemenschneider, F. (2019) · JMIR mhealth and uhealth · doi:10.2196/14120 · Cited by 59 · see citing works
Validity of wrist-worn consumer products to measure heart rate and energy expenditure
Thiebaud, R. S., Funk, M. D., Patton, J. C., Massey, B. L., Shay, T. E., Schmidt, M. G., & Giovannitti, N. (2018) · Digital Health · doi:10.1177/2055207618770322 · Cited by 56 · see citing works
In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?
Passler, S., Müller, N., & Senner, V. (2019) · Sensors · doi:10.3390/s19173641 · Cited by 55 · see citing works
Assistive devices of human knee joint: A review
Zhang, L., Liu, G., Han, B., Wang, Z., Han, L., & Jiao, Y. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.103394 · Cited by 56 · see citing works
Improving energy expenditure estimates from wearable devices: A machine learning approach
O’Driscoll, R., Turicchi, J., Hopkins, M., Horgan, G. W., Finlayson, G., & Stubbs, R. J. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1746088 · Cited by 56 · see citing works
Ludwig, M., Hoffmann, K., Endler, S., Asteroth, A., & Wiemeyer, J. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00778 · Cited by 55 · see citing works
Development and Pilot Test of a Virtual Reality Respiratory Biofeedback Approach
Blum, J., Rockstroh, C., & Göritz, A. S. (2020) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-020-09468-x · Cited by 60 · see citing works
Wearable Devices for the Assessment of Cognitive Effort for Human–Robot Interaction
Villani, V., Righi, M., Sabattini, L., & Secchi, C. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001635 · Cited by 45 · see citing works
Akbar, F., Mark, G. J., Prausnitz, S. R., Warton, E. M., East, J. A., Moeller, M. F., Reed, M. E., & Lieu, T. A. (2021) · JMIR Medical Informatics · doi:10.2196/24014 · Cited by 52 · see citing works
Maximal strength measurement: A critical evaluation of common methods—a narrative review
Warneke, K., Wagner, C., Keiner, M., Hillebrecht, M., Schiemann, S., Behm, D. G., Wallot, S., & WIRTH, K. J. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1105201 · Cited by 55 · see citing works
Methodological Shortcomings of Wrist-Worn Heart Rate Monitors Validations
Sartor, F., Papini, G. B., Cox, L. G. E., & Cleland, J. G. F. (2018) · Journal of Medical Internet Research · doi:10.2196/10108 · Cited by 51 · see citing works
Støve, M. P., Haucke, E., Nymann, M. L., Sigurdsson, T., & Larsen, B. T. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1535563 · Cited by 51 · see citing works
Huang, Z., Xu, Y., Cheng, Y., Xue, M., Deng, M., Jaffrezic-Renault, N. J., & Guo, Z. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00037g · Cited by 51 · see citing works
Noninvasive Continuous Monitoring of Vital Signs With Wearables: Fit for Medical Use?
Jacobsen, M., Dembek, T. A., Kobbe, G., Gaidzik, P. W., & Heinemann, L. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820904947 · Cited by 49 · see citing works
Navalta, J. W., Ramirez, G. G., Maxwell, C., Radzak, K. N., & McGinnis, G. R. (2020) · Scientific Reports · doi:10.1038/s41598-020-64185-z · Cited by 49 · see citing works
Molina‐García, P., Notbohm, H. L., Schumann, M., Argent, R., Hetherington‐Rauth, M., Stang, J. S., Bloch, W., Cheng, S., Ekelund, U., Sardinha, L. B., et al. (2022) · Sports Medicine · doi:10.1007/s40279-021-01639-y · Cited by 50 · see citing works
The Polar® OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
Schubert, M. M., Clark, A., & Rosa, A. B. D. L. (2018) · Sports Medicine International Open · doi:10.1055/a-0631-0920 · Cited by 47 · see citing works
Merrigan, J. J., Stovall, J. H., Stone, J. D., Stephenson, M., Finomore, V. S., & Hagen, J. A. (2022) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2022.2161820 · Cited by 49 · see citing works
Validity and Wearability of Consumer-based Fitness Trackers in Free-living Children
Brazendale, K., Decker, L., Hunt, E. T., Perry, M. W., Brazendale, A. B., Weaver, R. G., & Beets, M. W. (2019) · International journal of exercise science · doi:10.70252/bbtu4889 · Cited by 42 · see citing works
Accuracy of the Apple Watch 4 to Measure Heart Rate in Patients With Atrial Fibrillation
Seshadri, D. R., Bittel, B., Browsky, D., Houghtaling, P. L., Drummond, C. K., Desai, M. Y., & Gillinov, A. M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2950397 · Cited by 44 · see citing works
Self-citationLai, B. W., Davis, D., Narasaki‐Jara, M., Hopson, B. D., Powell, D. K., Gowey, M. A., Rocque, B. G., & Rimmer, J. H. (2020) · JMIR Serious Games · doi:10.2196/20667 · Cited by 44 · see citing works
Ackerman, K. E., Rogers, M. A., Heikura, I. A., Burke, L. M., Stellingwerff, T., Hackney, A. C., Verhagen, E., Schley, S., Saville, G. H., Mountjoy, M., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-107359 · Cited by 43 · see citing works
Accuracy of wrist-worn heart rate monitors for rate control assessment in atrial fibrillation
Al‐Kaisey, A., Koshy, A. N., Ha, F. J., Spencer, R., Toner, L., Sajeev, J., Teh, A. W., Farouque, O., & Lim, H. S. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.11.120 · Cited by 43 · see citing works
Sirisunhirun, P., Bandidniyamanon, W., Jrerattakon, Y., Muangsomboon, K., Pramyothin, P., Nimanong, S., Tanwandee, T., Charatcharoenwitthaya, P., Chainuvati, S. P., & Chotiyaputta, W. (2022) · BMC Gastroenterology · doi:10.1186/s12876-022-02147-7 · Cited by 42 · see citing works
Nielsen, J. C., Lin, Y., Figueiredo, M. J. D. O., Shamloo, A. S., Alfie, A., Bovéda, S., Dagres, N., Toro, D. D., Eckhardt, L. L., Ellenbogen, K. A., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.05.004 · Cited by 42 · see citing works
Detection and Monitoring of Viral Infections via Wearable Devices and Biometric Data
Goergen, C. J., Tweardy, M. J., Steinhubl, S. R., Wegerich, S., Singh, K., Mieloszyk, R. J., & Dunn, J. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-103020-040136 · Cited by 41 · see citing works
Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?
Martín-Escudero, P., Cabanas, A. M., Dotor-Castilla, M. L., Galindo-Canales, M., Miguel‐Tobal, F., Fernández, C., Fuentes, M. E., & Giannetti, R. (2023) · Bioengineering · doi:10.3390/bioengineering10020254 · Cited by 40 · see citing works
Navalta, J. W., Davis, D. W., Malek, E. M., Carrier, B., Bodell, N. G., Manning, J. W., Cowley, J. C., Funk, M. D., Lawrence, M. M., & DeBeliso, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-38329-w · Cited by 43 · see citing works
Polhemus, A. M., Novák, J. M., Ferrão, J. C., Simblett, S. K., Radaelli, M., Locatelli, P., Matcham, F., Kerz, M., Weyer, J., Burke, P., et al. (2020) · JMIR mhealth and uhealth · doi:10.2196/16043 · Cited by 40 · see citing works
Predicting lying, sitting, walking and running using Apple Watch and Fitbit data
Fuller, D., Anaraki, J. R., Simango, B., Rayner, M., Dorani, F., Bozorgi, A., Luan, H., & Basset, F. A. (2021) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2020-001004 · Cited by 41 · see citing works
Reliability of Trail Walking and Running Tasks Using the Stryd Power Meter
Navalta, J. W., Montes, J., Bodell, N. G., Aguilar, C. D., Radzak, K. N., Manning, J. W., & DeBeliso, M. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4068 · Cited by 41 · see citing works
Innovative Use of Wrist-Worn Wearable Devices in the Sports Domain: A Systematic Review
Santos-Gago, J. M., Merino, M. R., Vallarades-Rodriguez, S., Sabucedo, L. M. Á., Iglesias, M. J. F., & Soidán, J. L. G. (2019) · Electronics · doi:10.3390/electronics8111257 · Cited by 39 · see citing works
Costantino, A., Ferrara, M., Arnesano, M., & Fabrizio, E. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.106379 · Cited by 36 · see citing works
Jamieson, A., Chico, T., Jones, S. H., Chaturvedi, N., Hughes, A. D., & Orini, M. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00082-6 · Cited by 39 · see citing works
Systematic Review of Fitbit Charge 2 Validation Studies for Exercise Tracking
Irwin, C., & GARY, R. A. (2022) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000215 · Cited by 32 · see citing works
Helmer, P., Hottenrott, S., Rodemers, P., Leppich, R., Helwich, M., Pryss, R. C., Kranke, P., Meybohm, P., Winkler, B. E., & Sammeth, M. (2022) · Journal of Medical Internet Research · doi:10.2196/42359 · Cited by 33 · see citing works
Romagnoli, S., Ripanti, F., Morettini, M., Burattini, L., & Sbrollini, A. (2023) · Sensors · doi:10.3390/s23063350 · Cited by 37 · see citing works
Validation of the Polar OH1 and M600 optical heart rate sensors during front crawl swim training
Olstad, B. H., & Zinner, C. (2020) · PLoS ONE · doi:10.1371/journal.pone.0231522 · Cited by 34 · see citing works
Accuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Hermand, É., Coll, C., Richalet, J., & Lhuissier, F. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1337-2790 · Cited by 31 · see citing works
Wristbands in Home-Based Rehabilitation—Validation of Heart Rate Measurement
Jachymek, M., Jachymek, M., Kiedrowicz, R., Kaźmierczak, J., Płońska‐Gościniak, E., & Peregud‐Pogorzelska, M. (2021) · Sensors · doi:10.3390/s22010060 · Cited by 31 · see citing works
Using the computer mouse for stress measurement – An empirical investigation and critical review
Freihaut, P., & Göritz, A. S. (2020) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2020.102520 · Cited by 30 · see citing works
Kim, C., Song, J. H., & Kim, S. H. (2023) · Annals of Rehabilitation Medicine · doi:10.5535/arm.23019 · Cited by 29 · see citing works
A Review of Heartbeat Detection Systems for Automotive Applications
Arakawa, T. (2021) · Sensors · doi:10.3390/s21186112 · Cited by 29 · see citing works
Bytomski, A., Ritschel, G., Bierling, A. L., Bendas, J., Weidner, K., & Croy, I. (2020) · Psychology & Neuroscience · doi:10.1037/pne0000184 · Cited by 26 · see citing works
Mertala, P. (2021) · British Journal of Educational Technology · doi:10.1111/bjet.13125 · Cited by 29 · see citing works
Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis
Montalvo, S., Martinez, A., Arias, S., Lozano, A., Gonzalez, M., Dietze-Hermosa, M., Boyea, B. L., & Dorgo, S. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004482 · Cited by 25 · see citing works
Use of wearables for monitoring cardiometabolic health: A systematic review
Lee, M. A., Song, M., Bessette, H. C., Davis, M. C., Tyner, T. E., & Reid, A. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105218 · Cited by 30 · see citing works
Müller, C., Hengstmann, U., Fuchs, M., Kirchner, M. C., Kleinjung, F., Mathis, H., Martin, S., Bläse, I., & Perings, S. M. (2021) · Digital Health · doi:10.1177/20552076211019620 · Cited by 24 · see citing works
Wattanapisit, A., Ng, C. J., Angkurawaranon, C., Wattanapisit, S., Chaovalit, S., & Stoutenberg, M. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11259 · Cited by 28 · see citing works
Gajda, R., Gajda, J., Czuba, M., Knechtle, B., & Drygas, W. (2023) · Sports Medicine · doi:10.1007/s40279-023-01948-4 · Cited by 24 · see citing works
O’Driscoll, R., Turicchi, J., Hopkins, M., Gibbons, C., Larsen, S. C., Palmeira, A. L., Heitmann, B. L., Horgan, G. W., Finlayson, G., & Stubbs, R. J. (2019) · Health and Technology · doi:10.1007/s12553-019-00392-7 · Cited by 24 · see citing works
Biofeedback Treatment App for Pediatric Migraine: Development and Usability Study
Stubberud, A., Tronvik, E., Olsen, A., Gravdahl, G. B., & Linde, M. (2020) · Headache The Journal of Head and Face Pain · doi:10.1111/head.13772 · Cited by 24 · see citing works
Yavelberg, L., Zaharieva, D. P., Çınar, A., Riddell, M. C., & Jamnik, V. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817750401 · Cited by 23 · see citing works
- Authors
- GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y.
- Affiliations
- Cleveland Clinic (US)
- ORCID
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2017-08
- Volume
- 49
- Issue
- 8
- Pages
- 1697-1703
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2597782088
- Cited by
- 345
- References
- 15
- Citations by year
- 2026: 23 · 2025: 30 · 2024: 28 · 2023: 52 · 2022: 42 · 2021: 52 · 2020: 49 · 2019: 35 · 2018: 28 · 2017: 4
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Keywords
- wearable heart rate monitor, heart rate accuracy, aerobic exercise, wrist-worn devices, treadmill exercise, stationary cycling, elliptical trainer, exercise intensity, Apple Watch, Fitbit
- MeSH terms
- Adult, Equipment Design, Female, Heart, Humans, Male, Prospective Studies, Exercise, Electrocardiography, Ambulatory, Optical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review