Cited by 9Mobile Health and mHealth ApplicationsBlood Pressure and Hypertension StudiesTelemedicine and Telehealth Implementation

Digitally based blood pressure self-monitoring program that promotes hypertension self-management and health education among patients with low-income: usability study

Open access
Poblete, Jacqueline Yareli, Vawter, Natalie Lauren, Lewis, Sydney Virginia, Felisme, Earl Marc, Mohn, Paloma Adriana, Shea, Jennifer, Northrup, Adam William, Liu, Jie +2 more·2023·JMIR Human Factors

Published version of a preprint

Abstract

BACKGROUND: According to evidence-based clinical guidelines, adults with hypertension are advised to self-monitor their blood pressure (BP) twice daily. Self-measured BP monitoring is a recommended strategy for improving hypertension management. OBJECTIVE: We aimed to determine the feasibility and acceptability of a digitally based BP self-monitoring program that promotes hypertension self-management and health education among low-income patients. We hypothesized that the program would be highly feasible and acceptable and that at least 50% of the patients would use the monitor at the rate required for the reimbursement of the device's cost (16 days of measurements in any 30-day period). METHODS: Withings BPM Connect was deployed to patients at Family Health Centers of San Diego. Program elements included training, SMS text message reminders, and physician communication. Compliance, use, mean BP, and BP control status were calculated. A Kaplan-Meier time-to-event analysis was conducted to compare time to compliance between a strict definition (≥16 days in any rolling 30-day window) and a lenient definition (≥1 day per week for 4 consecutive weeks). A log-rank test was performed to determine whether the difference in time to compliance between the definitions was statistically significant. Mean systolic BP (SBP) and diastolic BP (DBP) before the intervention and after the intervention and mean change in SBP and DBP across patients were calculated. Paired sample t tests (2-tailed) were performed to assess the changes in SBP and DBP from before to after the intervention. RESULTS: A total of 179 patients received the monitors. The mean changes in SBP and DBP from before to after the intervention were +2.62 (SE 1.26) mm Hg and +3.31 (SE 0.71) mm Hg, respectively. There was a statistically significant increase in both SBP and DBP after the intervention compared with before the intervention (P=.04 and P<.001). At the first and last measurements, 37.5% (63/168) and 48.8% (82/168) of the patients had controlled BP, respectively. During the observation period, 83.3% (140/168) of the patients had at least 1 controlled BP measurement. Use decreased over time, with 53.6% (90/168) of the patients using their monitor at week 2 and only 25% (42/168) at week 11. Although only 25.6% (43/168) achieved the strict definition of compliance, 42.3% (71/168) achieved the lenient definition of compliance. The median time to compliance was 130 days for the strict definition and 95 days for the lenient definition. The log-rank test showed a statistically significant difference in time to compliance between the compliance definitions (P<.001). Only 26.8% (45/168) complied with the measurement rate that would result in device cost reimbursement. CONCLUSIONS: Few patients used the monitors at a rate that would result in reimbursement, raising financial feasibility concerns. Plans for sustaining costs among low-income patients need to be further evaluated.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/46313

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Patients frequently struggle with digital health literacy gaps, technology-induced anxiety, and the logistical burden of integrating rigid measurement protocols into their daily routines.

    “patients frequently struggle with digital health literacy gaps, technology-induced anxiety, and the logistical burden of integrating rigid measurement protocols into their daily routines [9,10].”

    From Clinical Efficacy and Patient Adherence Hurdles of Remote Patient Monitoring (RPM) Frameworks in Managing Hypertension and Type 2 Diabetes: A Scoping Review (2026) · cites this paper as [10]

    Table 6 (pp. 3–4) reports device-operation difficulties, busy schedules, and fear of viewing worrisome results; Principal Findings reports that only 27% met the measurement threshold and suggests it may be too stringent. These support practical barriers to monitoring, but the paper does not establish frequent technology-induced anxiety. Fear of a blood-pressure result is not the same as anxiety caused by the technology. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Lewis JR, Sauro J. Can I leave this one out? The effect of dropping an item from the SUS. J Usability Stud 2017;13(1):38-46 [FREE Full text]

Authors
Poblete, J. Y., Vawter, N. L., Lewis, S. V., Felisme, E. M., Mohn, P. A., Shea, J., Northrup, A. W., Liu, J., Al-Rousan, T., & Godino, J. G.
Affiliations
  • Family Health Centers of San Diego (US)
  • University of California San Diego (US)
Corresponding author
Godino, Job Gideon
Venue
JMIR Human Factors
Published
2023-07-24
Volume
10
Pages
e46313
ISSN
2292-9495 (ISSN-L)
OpenAlex
W4381095292
Cited by
9
References
22
Citations by year
2026: 5 · 2025: 3 · 2024: 1
FWCI
3.18
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • JMIR Human Factors (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • American Heart Association
  • National Institutes of Health
  • National Heart, Lung, and Blood Institute (K23HL148530)
Topics
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
Keywords
hypertension, self-measured blood pressure, hypertension self-management, low-income patients, digital health interventions, SMS reminders, health education, blood pressure control, device compliance, usability, family health centers, primary care, health equity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review