Workarounds Emerging From Electronic Health Record System Usage: Consequences for Patient Safety, Effectiveness of Care, and Efficiency of Care
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Health care providers resort to informal temporary practices known as workarounds for handling exceptions to normal workflow unintendedly imposed by electronic health record systems (EHRs). Although workarounds may seem favorable at first sight, they are generally suboptimal and may jeopardize patient safety, effectiveness of care, and efficiency of care. OBJECTIVE: Research into the scope and impact of EHR workarounds on patient care processes is scarce. This paper provides insight into the effects of EHR workarounds on organizational workflows and outcomes of care services by identifying EHR workarounds and determining their rationales, scope, and impact on health care providers' workflows, patient safety, effectiveness of care, and efficiency of care. Knowing the rationale of a workaround provides valuable clues about the source of origin of each workaround and how each workaround could most effectively be resolved. Knowing the scope and impact a workaround has on EHR-related safety, effectiveness, and efficiency provides insight into how to address related concerns. METHODS: Direct observations and follow-up semistructured interviews with 31 physicians, 13 nurses, and 3 clerks and qualitative bottom-up coding techniques was used to identify, analyze, and classify EHR workarounds. The research was conducted within 3 specialties and settings at a large university hospital. Rationales were associated with work system components (persons, technology and tools, tasks, organization, and physical environment) of the Systems Engineering Initiative for Patient Safety (SEIPS) framework to reveal their source of origin as well as to determine the scope and the impact of each EHR workaround from a structure-process-outcome perspective. RESULTS: A total of 15 rationales for EHR workarounds were identified of which 5 were associated with persons, 4 with technology and tools, 4 with the organization, and 2 with the tasks. Three of these 15 rationales for EHR workarounds have not been identified in prior research: data migration policy, enforced data entry, and task interference. CONCLUSIONS: EHR workaround rationales associated with different SEIPS work system components demand a different approach to be resolved. Persons-related workarounds may most effectively be resolved through personal training, organization-related workarounds through reviewing organizational policy and regulations, tasks-related workarounds through process redesign, and technology- and tools-related workarounds through EHR redesign efforts. Furthermore, insights gained from knowing a workaround's degree of influence as well as impact on patient safety, effectiveness of care, and efficiency of care can inform design and redesign of EHRs to further align EHR design with work contexts, subsequently leading to better organization and (safe) provision of care. In doing so, a research team in collaboration with all stakeholders could use the SEIPS framework to reflect on the current and potential future configurations of the work system to prevent unfavorable workarounds from occurring and how a redesign of the EHR would impact interactions between the work system components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The “Meaningful Use” Regulation for Electronic Health Records
Blumenthal, D., & Tavenner, M. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006114 · Cited by 2,059
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Allocation of Physician Time in Ambulatory Practice: A Time and Motion Study in 4 Specialties
Sinsky, C., Colligan, L., Li, L., Prgomet, M., Reynolds, S., Goeders, L., Westbrook, J., Tutty, M., & Blike, G. (2016) · Annals of Internal Medicine · doi:10.7326/m16-0961 · Cited by 1,494 · cited 1×
“Research has shown that the ratio between provider-EHR system and provider-patient interaction demands careful balancing [60-62] and that EHRs claim a significant portion of physicians’ time and draw attention away from their direct interactions with patients and from their personal lives [63,64].”
BackgroundHolden, R. J., Carayon, P., Gurses, A. P., Hoonakker, P., Hundt, A. S., Ozok, A. A., & Rivera-Rodriguez, A. J. (2013) · Ergonomics · doi:10.1080/00140139.2013.838643 · Cited by 1,221 · cited 10×
“That is, these workaround rationales resonate most closely with the EHR [52].”
BackgroundMethodInfluentialAngst, C. M., & Agarwal, R. (2009) · MIS Quarterly · doi:10.2307/20650295 · Cited by 1,043
Types of Unintended Consequences Related to Computerized Provider Order Entry
Campbell, E. M., Sittig, D. F., Ash, J. S., Guappone, K. P., & Dykstra, R. H. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2042 · Cited by 823
Koppel, R., Wetterneck, T., Telles, J. L., & Karsh, B.-T. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2616 · Cited by 685 · cited 5×
“For example, workarounds may bypass important security blocks (eg, working in a so-called emergency mode in nonemergency situations and thereby omitting security checks) [33] or lead to administering medication to the wrong patient or in incorrect doses [31,33].”
BackgroundInfluentialGREENHALGH, T., POTTS, H. W. W., WONG, G., BARK, P., & SWINGLEHURST, D. (2009) · The Milbank Quarterly · doi:10.1111/j.1468-0009.2009.00578.x · Cited by 541 · cited 1×
“Many causes of unfavorable outcomes of adopting EHRs can be traced back to discrepancies between the behavior and intentions of EHR users and the workflow as dictated by the EHR—often termed workflow mismatches [22,23,27-29].”
BackgroundCategorizing the unintended sociotechnical consequences of computerized provider order entry
Ash, J. S., Sittig, D. F., Dykstra, R. H., Guappone, K., Carpenter, J. D., & Seshadri, V. (2007) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2006.05.017 · Cited by 267 · cited 4×
“Many causes of unfavorable outcomes of adopting EHRs can be traced back to discrepancies between the behavior and intentions of EHR users and the workflow as dictated by the EHR—often termed workflow mismatches [22,23,27-29].”
BackgroundInfluentialCifuentes, M., Davis, M., Fernald, D., Gunn, R., Dickinson, P., & Cohen, D. J. (2015) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2015.s1.150133 · Cited by 164
Cited by
Dykes, S., & Chu, C. H. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.15581 · Cited by 66
“Their absence from these discussions results in technologies that lack functionality, interoperability and can lead to workarounds (Blijleven et al., 2017; Koppel et al., 2008).”
BackgroundDunn Lopez, K., Chin, C.-L., Leitão Azevedo, R. F., Kaushik, V., Roy, B., Schuh, W., Banks, K., Sousa, V., & Morrow, D. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103359 · Cited by 62
Yoo, H. J., & Lee, H. (2022) · Journal of Nursing Management · doi:10.1111/jonm.13880 · Cited by 28
“The absence of nurses from these discussions leads to technologies without functionality and interoperability, which lead to workarounds (Bagot et al., 2020; Blijleven et al., 2017).”
BackgroundLivesay, K., Petersen, S., Walter, R., Zhao, L., Butler-Henderson, K., & Abdolkhani, R. (2023) · JMIR Nursing · doi:10.2196/46819 · Cited by 23
Metadata
- Authors
- Blijleven, V., Koelemeijer, K., Wetzels, M., & Jaspers, M.
- Venue
- JMIR Human Factors
- Publisher
- JMIR Publications Inc.
- Published
- 2017-10-05
- Volume
- 4
- Issue
- 4
- Pages
- e27
- ISSN
- 2292-9495 (ISSN-L)
- OpenAlex
- W2761341529
- Cited by
- 112
- References
- 14
- FWCI
- 12.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.