CoChat

Testing the Effect of Computer-Assisted Detection on Interpretive Performance in Screening Mammography

Taplin, Stephen H., Rutter, Carolyn M., Lehman, Constance D. · 2006 · American Journal of Roentgenology
Cited by 52

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of our study was to test whether the use of computer-assisted detection (CAD) improves sensitivity at no cost to specificity for the detection of breast cancer and enables more accurate assessment of fatty breast tissue compared with dense breast tissue. MATERIALS AND METHODS: We created a stratified random sample of screening mammograms weighted with difficult cases split evenly among women with fatty breast tissue and those with dense breast tissue: 114 patients were cancer-free, 114 had cancer 1 year after screening, and 113 had cancer 13-24 months after screening. In test settings 6 months apart, 19 community radiologists interpreted 341 bilateral screening mammograms with and without CAD. We compared the sensitivity and specificity using regression models adjusting for repeated measures. RESULTS: CAD assistance did not affect overall sensitivity (cancer by 1 year: 63.2% without CAD and 62.0% with CAD; cancer in 13-24 months: 33.5% without CAD and 32.3% with CAD), but its effect differed for visible masses that were marked by CAD compared with those that were not marked by CAD (hereafter referred to as "unmarked"). CAD was associated with improved sensitivity for marked visible cancers and decreased sensitivity for unmarked visible masses; the sensitivities without and with CAD, respectively, were as follows: marked cancer by 1 year, 82.7% versus 83.1%; marked cancer in 13-24 months, 44.2% versus 57.9%; unmarked cancer by 1 year, 37.4% versus 30.1%; unmarked cancer in 13-24 months, 29.7% versus 23.0% (p < 0.03 for both interactions between assistance and CAD marking for cancer by 1 year and cancer in 13-24 months). CAD marked 77% (70/91) of the visible cancers by 1 year and 67.3% (37/55) of the visible cancers in 13-24 months. CAD marked more visible calcified lesions (86%) than masses and asymmetric densities (67%) (p < 0.05). Overall specificity was 72% without and 75% with CAD (p < 0.02). CAD had a greater effect on both specificity (p < 0.02) and sensitivity (p < 0.03) among radiologists who interpret more than 50 mammograms per week. The results were the same for fatty breast tissue and dense breast tissue. CONCLUSION: In this experiment, CAD increased interpretive specificity but did not affect sensitivity because visible noncalcified lesions that went unmarked by CAD were less likely to be assessed as abnormal by radiologists. Breast density did not affect CAD's performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.05.0940

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 52

Metadata

Authors
Taplin, S. H., Rutter, C. M., & Lehman, C. D.
Venue
American Journal of Roentgenology
Published
2006-12
Volume
187
Issue
6
Pages
1475-1482
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2063838177
Cited by
52
References
1
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Testing the Effect of Computer-Assisted Detection on Interpretive Performance in Screening Mammography. https://app.cochat.ai/papers/10.2214/ajr.05.0940
The paper
Taplin, S. H., Rutter, C. M., & Lehman, C. D. (2006). Testing the Effect of Computer-Assisted Detection on Interpretive Performance in Screening Mammography. American Journal of Roentgenology. https://doi.org/10.2214/ajr.05.0940

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.