MR Elastography of Liver Tumors: Preliminary Results
Open accessAbstract
OBJECTIVE: The purpose of this study was to evaluate the potential value of MR elastography (MRE) in the characterization of solid liver tumors. MATERIALS AND METHODS: Forty-four liver tumors (14 metastatic lesions, 12 hepatocellular carcinomas, nine hemangiomas, five cholangiocarcinomas, three cases of focal nodular hyperplasia, and one hepatic adenoma) were evaluated with MRE. MRE was performed with a 1.5-T system with a modified phase-contrast gradient-echo sequence to collect axial wave images sensitized along the through-plane motion direction. The tumors were identified on T2- and T1-weighted and gadolinium-enhanced T1-weighted images, and the MRE images were obtained through the tumor. A stiffness map (elastogram) was generated in an automated process consisting of an inversion algorithm. The mean shear stiffness of the tumor was calculated with a manually specified region of interest over the tumor in the stiffness map. The stiffness value of tumor-free hepatic parenchyma was calculated. Statistical analysis was performed on the stiffness values for differentiation of normal liver, fibrotic liver, benign tumors, and malignant tumors. RESULTS: Malignant liver tumors had significantly greater mean shear stiffness than benign tumors (10.1 kPa vs 2.7 kPa, p < 0.001), fibrotic liver (10.1 kPa vs 5.9 kPa, p < 0.001), and normal liver (10.1 kPa vs 2.3 kPa, p < 0.001). Fibrotic livers had stiffness values overlapping both the benign and the malignant tumors. A cutoff value of 5 kPa accurately differentiated malignant tumors from benign tumors and normal liver parenchyma in this preliminary investigation. CONCLUSION: MR elastography is a promising noninvasive technique for assessing solid liver tumors. Use of MRE may lead to new quantitative tissue characterization parameters for differentiating benign and malignant liver tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer cells compress intratumour vessels
Padera, T. P., Stoll, B. R., Tooredman, J. B., Capen, D., Tomaso, E. D., & Jain, R. K. (2004) · Nature · doi:10.1038/427695a · Cited by 857
Cited by
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Self-citationAdvances in the Early Diagnosis of Hepatocellular Carcinoma
Wang, W., & Wei, C. (2020) · Genes & Diseases · doi:10.1016/j.gendis.2020.01.014 · Cited by 492
Sleeboom, J. J. F., van Tienderen, G. S., Schenke-Layland, K., van der Laan, L. J. W., Khalil, A. A., & Verstegen, M. M. A. (2024) · Science Translational Medicine · doi:10.1126/scitranslmed.adg3840 · Cited by 375
Are cancer cells really softer than normal cells?
Alibert, C., Goud, B., & Manneville, J. (2017) · Biology of the Cell · doi:10.1111/boc.201600078 · Cited by 366
Complex mechanics of the heterogeneous extracellular matrix in cancer
Malandrino, A., Mak, M., Kamm, R. D., & Moeendarbary, E. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.02.003 · Cited by 192
Metadata
- Authors
- Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2008-06
- Volume
- 190
- Issue
- 6
- Pages
- 1534-1540
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2048613709
- Cited by
- 312
- References
- 1
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR Elastography of Liver Tumors: Preliminary Results. https://app.cochat.ai/papers/10.2214/ajr.07.3123
- The paper
- Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L. (2008). MR Elastography of Liver Tumors: Preliminary Results. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.3123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.