The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
MR Elastography of Liver Tumors: Preliminary Results
Open accessAbstract
OBJECTIVE: The purpose of this study was to evaluate the potential value of MR elastography (MRE) in the characterization of solid liver tumors. MATERIALS AND METHODS: Forty-four liver tumors (14 metastatic lesions, 12 hepatocellular carcinomas, nine hemangiomas, five cholangiocarcinomas, three cases of focal nodular hyperplasia, and one hepatic adenoma) were evaluated with MRE. MRE was performed with a 1.5-T system with a modified phase-contrast gradient-echo sequence to collect axial wave images sensitized along the through-plane motion direction. The tumors were identified on T2- and T1-weighted and gadolinium-enhanced T1-weighted images, and the MRE images were obtained through the tumor. A stiffness map (elastogram) was generated in an automated process consisting of an inversion algorithm. The mean shear stiffness of the tumor was calculated with a manually specified region of interest over the tumor in the stiffness map. The stiffness value of tumor-free hepatic parenchyma was calculated. Statistical analysis was performed on the stiffness values for differentiation of normal liver, fibrotic liver, benign tumors, and malignant tumors. RESULTS: Malignant liver tumors had significantly greater mean shear stiffness than benign tumors (10.1 kPa vs 2.7 kPa, p < 0.001), fibrotic liver (10.1 kPa vs 5.9 kPa, p < 0.001), and normal liver (10.1 kPa vs 2.3 kPa, p < 0.001). Fibrotic livers had stiffness values overlapping both the benign and the malignant tumors. A cutoff value of 5 kPa accurately differentiated malignant tumors from benign tumors and normal liver parenchyma in this preliminary investigation. CONCLUSION: MR elastography is a promising noninvasive technique for assessing solid liver tumors. Use of MRE may lead to new quantitative tissue characterization parameters for differentiating benign and malignant liver tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Management of Hepatocellular Carcinoma *
Bruix, J., & Sherman, M. (2005) · Hepatology · doi:10.1002/hep.20933 · Cited by 5,857
Clinical Management of Hepatocellular Carcinoma. Conclusions of the Barcelona-2000 EASL Conference
Bruix, J., Sherman, M., Llovet, J. M., Beaugrand, M., Lencioni, R., Burroughs, A. K., Christensen, E., Pagliaro, L., Colombo, M., & Rodés, J. (2001) · Journal of Hepatology · doi:10.1016/s0168-8278(01)00130-1 · Cited by 4,089
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 2×
“Researchers using sonography [5] and MRI [6] have developed imaging techniques for noninvasive assessment of the mechanical properties of tissues.”
BackgroundMethodSelf-citationPhysical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Self-citationAssessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Self-citationElastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Cancer cells compress intratumour vessels
Padera, T. P., Stoll, B. R., Tooredman, J. B., Capen, D., Tomaso, E. D., & Jain, R. K. (2004) · Nature · doi:10.1038/427695a · Cited by 857
Cited by
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Self-citationAdvances in the Early Diagnosis of Hepatocellular Carcinoma
Wang, W., & Wei, C. (2020) · Genes & Diseases · doi:10.1016/j.gendis.2020.01.014 · Cited by 492
Sleeboom, J. J. F., van Tienderen, G. S., Schenke-Layland, K., van der Laan, L. J. W., Khalil, A. A., & Verstegen, M. M. A. (2024) · Science Translational Medicine · doi:10.1126/scitranslmed.adg3840 · Cited by 375
Nicolas-Boluda, A., Vaquero, J., Vimeux, L., Guilbert, T., Barrin, S., Kantari-Mimoun, C., Ponzo, M., Renault, G., Deptula, P., Pogoda, K., et al. (2021) · eLife · doi:10.7554/elife.58688 · Cited by 368
Are cancer cells really softer than normal cells?
Alibert, C., Goud, B., & Manneville, J. (2017) · Biology of the Cell · doi:10.1111/boc.201600078 · Cited by 366
Quantitative Elastography Methods in Liver Disease: Current Evidence and Future Directions
Kennedy, P., Wagner, M., Castéra, L., Hong, C. W., Johnson, C. L., Sirlin, C. B., & Taouli, B. (2018) · Radiology · doi:10.1148/radiol.2018170601 · Cited by 271
Complex mechanics of the heterogeneous extracellular matrix in cancer
Malandrino, A., Mak, M., Kamm, R. D., & Moeendarbary, E. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.02.003 · Cited by 192
“lobe of human liver (arrow in the left T1-weighted magnetic resonance image) [70] (b) Second harmonic generation image of an ex vivo mouse mammary tumor indicates”
BackgroundMethodLiver fibrosis assessment: MR and US elastography
Ozturk, A., Olson, M. C., Samir, A. E., & Venkatesh, S. K. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03269-4 · Cited by 168
Self-citationGeneral review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Brain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
Metadata
- Authors
- Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2008-06
- Volume
- 190
- Issue
- 6
- Pages
- 1534-1540
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2048613709
- Cited by
- 312
- References
- 25
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.