CoChat

Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality

O'Connell, Avice, Conover, David L., Zhang, Yan, Seifert, Posy, Logan-Young, Wende, Lin, Chuen-Fu Linda, Sahler, Lawrence, Ning, Ruola · 2010 · American Journal of Roentgenology
Cited by 220

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The primary objectives of this pilot study were to evaluate the radiation dose, breast coverage, and image quality of cone-beam breast CT compared with a conventional mammographic examination. Image quality analysis was focused on the concordance of cone-beam breast CT with conventional mammography in terms of mammographic findings. SUBJECTS AND METHODS: This prospective study was performed from July 2006 through August 2008. Twenty-three women were enrolled who met the inclusion criteria, which were age 40 years or older with final BI-RADS assessment category 1 or 2 lesions on conventional mammograms within the previous 6 months. The breasts were imaged with a flat-panel detector-based cone-beam CT system, and the images were reviewed with a 3D visualization system. Cone-beam breast CT image data sets and the corresponding mammograms were reviewed by three qualified mammographers. The parameters assessed and compared in this pilot study were radiation dose, breast tissue coverage, and image quality, including detectability of masses and calcifications. The mammograms and cone-beam breast CT images were independently reviewed side by side, and the reviewers were not blinded to the other technique. The observed agreement and Cohen's kappa were used to evaluate agreement between the mammographic and cone-beam breast CT findings and interobserver agreement. Each subject responded to a questionnaire on multiple parameters, including comfort of the cone-beam breast CT examination compared with mammography. RESULTS: For a conventional mammographic examination, the average glandular radiation dose ranged from 2.2 to 15 mGy (mean, 6.5 [SD, 2.9] mGy). For cone-beam breast CT, the average glandular dose ranged from 4 to 12.8 mGy (mean, 8.2 [SD, 1.4] mGy). The average glandular dose from cone-beam breast CT was generally within the range of that from conventional mammography. For heterogeneously dense and extremely dense breasts, the difference between the mean dose of conventional mammography and that of cone-beam breast CT was not statistically significant (7.0 vs 8.1 mGy, p = 0.06). Breast tissue coverage was statistically significantly better with cone-beam breast CT than with mammography in the lateral (p < 0.0001), medial (p < 0.0001), and posterior (p = 0.0002) aspects. Mammography had statistically significantly better coverage than cone-beam breast CT in the axilla and axillary tail (p < 0.0001). Overall, most calcifications and all masses detected with mammography were also detected with cone-beam breast CT. The interobserver agreement on cone-beam breast CT was 83.7% in the detectability of imaging findings. The overall interobserver agreement on type of findings, size of findings (<1, 1-4.99, and > or = 5 mm), and location of findings was 77.2%, 84.8%, and 78.3%, respectively. CONCLUSION: The results of this study show that cone-beam breast CT can be used to image the entire breast from chest wall to nipple with sufficient spatial and contrast resolution for detection of masses and calcifications at a radiation dose within the range of that of conventional mammography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.08.1017

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 220

Metadata

Authors
O'Connell, A., Conover, D. L., Zhang, Y., Seifert, P., Logan-Young, W., Lin, C.-F. L., Sahler, L., & Ning, R.
Venue
American Journal of Roentgenology
Published
2010-08
Volume
195
Issue
2
Pages
496-509
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2008521294
Cited by
220
References
15
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.