Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 492

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning

Christner, Jodie A., Kofler, James M., McCollough, Cynthia H.·2010·American Journal of Roentgenology

Abstract

OBJECTIVE: The objective of our study was to compare dose-length product (DLP)-based estimates of effective dose with organ dose-based calculations using tissue-weighting factors from publication 103 of the International Commission on Radiological Protection (ICRP) or dual-energy CT protocols. MATERIALS AND METHODS: Using scanner- and energy-dependent organ dose coefficients, we calculated effective doses for CT examinations of the head, chest, coronary arteries, liver, and abdomen and pelvis using routine clinical single- or dual-energy protocols and tissue-weighting factors published in 1991 in ICRP publication 60 and in 2007 in ICRP publication 103. Effective doses were also generated from the respective DLPs using published conversion coefficients that depend only on body region. For each examination type, the same volume CT dose index was used for single- and dual-energy scans. RESULTS: Effective doses calculated for CT examinations using organ dose estimates and ICRP 103 tissue-weighting factors differed relative to ICRP 60 values by -39% (-0.5 mSv, head), 14% (1 mSv, chest), 36% (4 mSv, coronary artery), 4% (0.6 mSv, liver), and -7% (-1 mSv, abdomen and pelvis). DLP-based estimates of effective dose, which were derived using ICRP 60-based conversion coefficients, were less than organ dose-based estimates for ICRP 60 by 4% (head), 23% (chest), 37% (coronary artery), 12% (liver), and 19% (abdomen and pelvis) and for ICRP 103 by -34% (head), 37% (chest), 74% (coronary artery), 16% (liver), and 12% (abdomen and pelvis). All results were energy independent. CONCLUSION: These differences in estimates of effective dose suggest the need to reassess DLP to E conversion coefficients when adopting ICRP 103, particularly for scans over the breast. For the evaluated scanner, DLP to E conversion coefficients were energy independent, but ICRP 60-based conversion coefficients underestimated effective dose relative to organ dose-based calculations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.09.3462

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 492

Metadata

Authors
Christner, J. A., Kofler, J. M., & McCollough, C. H.
Venue
American Journal of Roentgenology
Published
2010-04
Volume
194
Issue
4
Pages
881-889
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2043654907
Cited by
492
References
28
FWCI
24.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning. https://app.cochat.ai/papers/10.2214/ajr.09.3462
The paper
Christner, J. A., Kofler, J. M., & McCollough, C. H. (2010). Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.3462

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.