The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
False-Positive Findings at Contrast-Enhanced Breast MRI: A BI-RADS Descriptor Study
Abstract
OBJECTIVE: Breast MRI has high sensitivity in breast cancer detection, and the BI-RADS MRI lexicon was a step toward standardized description of lesions. However, false-positive findings occur and lead to unnecessary biopsy. The purpose of this investigation was to identify criteria for false-positive findings in clinical practice. MATERIALS AND METHODS: Eligible for investigation were all breast MRI examinations from a consecutive 16-month time period that had histopathologic verification and findings classified as BI-RADS category 4-6 in the initial MRI report. Accordingly, 132 patients with 120 malignant and 31 benign lesions were enrolled. Two blinded observers categorized lesions into mass or nonmass and used BI-RADS to identify descriptor distribution differences between the benign and malignant subgroups. RESULTS: The ratio of mass to nonmass lesions differed significantly (p < 0.001) between benign (1.2:1) and malignant (7:1) findings. Seventeen mass and 14 nonmass lesions were false-positive, and 105 mass and 15 nonmass lesions were true-positive. Among mass lesions, it was possible to differentiate malignant and benign lesions on the basis of margin (smooth, irregular, or spiculated) and dynamic enhancement features (p < 0.05). Among nonmass lesions, only stippled enhancement had a significant difference between the subgroups (p < 0.05). Tumor diameter had no influence on the correct diagnosis of nonmass lesions (p = 0.301). Conversely, among mass lesions, false-positive lesions were smaller than true-positive lesions (p = 0.01). CONCLUSION: Nonmass lesions were the major cause of false-positive breast MRI findings. BI-RADS descriptors are not sufficient for differentiating benign and malignant nonmass lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics Notes: Diagnostic tests 2: predictive values
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6947.102 · Cited by 1,711
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
A YOLOv3 Deep Neural Network Model to Detect Brain Tumor in Portable Electromagnetic Imaging System
Hossain, A., Islam, M. T., Islam, M. S., Chowdhury, M. E. H., Almutairi, A. F., Razouqi, Q. A., & Misran, N. (2021) · IEEE Access · doi:10.1109/access.2021.3086624 · Cited by 66
Identification of Breast Cancer Using Integrated Information from MRI and Mammography
Yang, S.-N., Li, F.-J., Liao, Y.-H., Chen, Y.-S., Shen, W.-C., & Huang, T.-C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128404 · Cited by 36
“Non-mass lesions were the major cause of false-positive breast MRI findings [26].”
Background
Metadata
- Authors
- Baltzer, P. A. T., Benndorf, M., Dietzel, M., Gajda, M., Runnebaum, I. B., & Kaiser, W. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2010-06
- Volume
- 194
- Issue
- 6
- Pages
- 1658-1663
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1995618743
- Cited by
- 196
- References
- 1
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: False-Positive Findings at Contrast-Enhanced Breast MRI: A BI-RADS Descriptor Study. https://app.cochat.ai/papers/10.2214/ajr.09.3486
- The paper
- Baltzer, P. A. T., Benndorf, M., Dietzel, M., Gajda, M., Runnebaum, I. B., & Kaiser, W. A. (2010). False-Positive Findings at Contrast-Enhanced Breast MRI: A BI-RADS Descriptor Study. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.3486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.