CoChat

Characterization of Adrenal Lesions at Chemical-Shift MRI: A Direct Intraindividual Comparison of In- and Opposed-Phase Imaging at 1.5 T and 3 T

Ream, Justin M., Gaing, Byron, Mussi, Thais C., Rosenkrantz, Andrew B. · 2015 · American Journal of Roentgenology
Cited by 32

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE. The purpose of this article is to perform an intraindividual comparison between 1.5 T and 3 T chemical-shift MRI in differentiating adrenal adenomas and nonadenomas, including comparison of quantitative thresholds. MATERIALS AND METHODS. In this retrospective study, 37 adrenal lesions in 36 patients (20 men and 16 women; mean [± SD] age, 66.7 ± 12.9 years; 27 benign adenomas in 27 patients; 10 nonadenomas in nine patients) imaged at 1.5 T and 3 T were identified. Two readers qualitatively assessed intralesional signal loss between in- and opposed-phase images. One reader placed ROIs on adrenal lesions, spleen, liver, and muscle. Quantitative measures of signal loss, such as signal intensity (SI) index, adrenal-to-spleen ratio, adrenal-to-liver ratio, and adrenal-to-muscle ratio, were calculated. Qualitative and quantitative measures between field strengths were assessed with McNemar test and ROC analysis, respectively. RESULTS. Accuracy in qualitative adenoma identification (86.5% [32/37] at 1.5 T and 81.1% [30/37] at 3 T for reader 1; 81.1% [30/37] at 1.5 T and 83.8% [31/37] at 3 T for reader 2; both p ≥ 0.180) was equivalent at both field strengths. AUCs were not statistically significantly different between field strengths for quantitative measures: AUCs at 1.5 T versus 3 T were 0.956 versus 0.915 for SI index, 0.963 versus 0.870 for adrenal-to-spleen ratio, 0.935 versus 0.852 for adrenal-to-liver ratio, and 0.948 versus 0.948 for adrenal-to-muscle ratio (all p > 0.11). The optimal threshold for SI index was lower at 3 T (> 7.4%) than at 1.5 T (> 21.6%) but had similar sensitivity (1.5 T, 92.6% [25/27]; 3 T, 88.9% [24/27]) and specificity (1.5 T, 90.0% [9/10]; 3 T, 90.0% [9/10]). CONCLUSION. Chemical-shift imaging has similar diagnostic efficacy for differentiating adrenal adenomas and nonadenomas at 1.5 T and 3 T. However, quantitative measures have different thresholds for this differentiation at 3 T; in particular, the commonly applied SI index is much lower at 3 T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.14.12941

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 32

Metadata

Authors
Ream, J. M., Gaing, B., Mussi, T. C., & Rosenkrantz, A. B.
Venue
American Journal of Roentgenology
Published
2015-03
Volume
204
Issue
3
Pages
536-541
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2120893345
Cited by
32
References
4
FWCI
3.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.