The Doppler signal: where does it come from and what does it mean?
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Doppler sonographic measurement of blood velocity and associated physiologic parameters is a powerful diagnostic technique. State-of-the-art instrumentation incorporates velocity measurement with two-dimensional imaging capability; it uses intensity and color coding to display complex physiologic and anatomic data to the observer in an easily understood format. Although the concepts underlying Doppler sonography are not complex, mastery of the technique requires extra training and commitment. The principal features and clinical practicalities associated with Doppler sonography are summarized in the following paragraphs. Continuous-wave Doppler is very sensitive to small vessels and has no upper velocity limit. In addition, the instrumentation is not complex and produces relatively low acoustic power. A significant drawback to continuous-wave Doppler is that there is no depth sensitivity, and thus complex structures or multiple vessels can give conflicting information. Pulsed Doppler (including duplex and color-flow) instrumentation has the capability of depth resolution and a variable sample volume. Pulsed Doppler equipment is prone to aliasing (false velocity indications) under some circumstances and also produces higher peak power levels than does continuous-wave equipment. Duplex equipment is more complex and expensive than continuous-wave equipment because the two-dimensional and Doppler modes must be synchronized in operation and display. Color-flow equipment is extremely complex and expensive. Color flow provides information of a qualitative and limited quantitative value. Absolute measurement still requires range-gate measurements. Technical and anatomic factors will affect the measured velocity profiles. Thus, it is important to fully appreciate the anatomy of the vessel and the angle between the vessel and the ultrasound beam when making quantitative measurements. Measurements that evaluate the velocity waveform and make use of ratios, such as the pulsatility index, eliminate the need for angular corrections; however, artifacts due to unappreciated anatomic or wall characteristics may lead to incorrect information if all parameters are not fully understood. Doppler sonographic measurements may be used to determine the presence of flow, determine the direction of flow, identify time-varying velocity characteristics, and detect velocity disturbances. Because flow and velocity are related, it is possible to estimate flow from velocity measurements with careful calibration and proper precautions. Velocity is related to flow, which, in turn, is related to both pressure and vascular resistance.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance
TRUDINGER, B. J., GILES, W. B., COOK, C. M., BOMBARDIERI, J., & COLLINS, L. (1985) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb01044.x · Cited by 561 · cited 2×
“Duplex Doppler imaging offers many advantages over either continuous- or pulsed-wave Doppler, and it has been this technology that has allowed Doppler to become so clinically useful in evaluating carotid vessels [16-20], fetal and uterine vessels [ 21 -25 ], and abdominal vessels [1 0, 15, 26-28].”
BackgroundMethodWladimiroff, J. W., van den Wijngaard, J. A. G. W., Degani, S., Noordam, M. J., van Eyck, J., & Tonge, H. M. (1987) · PubMed · Cited by 348
Pulsed Doppler with B-mode imaging for quantitative blood flow measurement
Gill, R. W. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90014-0 · Cited by 265 · cited 1×
“In principle, sonography makes possible the estimation of volume flow (in mI/sec) by careful measurement of the area (image) and the velocity distribution (Doppler trace) [ 13 , 14].”
BackgroundEvaluation of renal transplant rejection by duplex Doppler examination: value of the resistive index
Rifkin, M., Needleman, L., Pasto, M., Kurtz, A., Foy, P., McGlynn, E., Canino, C., Baltarowich, O., Pennell, R., & Goldberg, B. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.4.759 · Cited by 259 · cited 1×
“The Pourcelot (or resistive) index is slightly more sensitive in differentiating abnormal waveforms because the denominator never becomes zero [ 26 ].”
BackgroundMethodology and basic problems related to blood flow studies in the human fetus
Eik-Nes, S. H., Maršál, K., & Kristoffersen, K. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90167-4 · Cited by 194
Duplex carotid sonography: criteria for stenosis, accuracy, and pitfalls.
Jacobs, N. M., Grant, E. G., Schellinger, D., Byrd, M., Richardson, J. D., & COHAN, S. L. (1985) · Radiology · doi:10.1148/radiology.154.2.3880910 · Cited by 125
Fetal blood flow velocity waveforms as predictors of growth retardation.
Arduini, D., Rizzo, G., Romaninï, C., & Mancuso, S. (1987) · PubMed · Cited by 103
Computer based pattern recognition of carotid arterial disease using pulsed Doppler ultrasound
Greene, F. M., Beach, K. W., Strandness, D. E., Fell, G., & Phillips, D. J. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90095-3 · Cited by 56 · cited 1×
“Duplex Doppler imaging offers many advantages over either continuous- or pulsed-wave Doppler, and it has been this technology that has allowed Doppler to become so clinically useful in evaluating carotid vessels [ 16-20 ], fetal and uterine vessels [21 -25], and abdominal vessels [1 0, 15, 26-28].”
MethodAbsolute flow measurements using pulsed Doppler US. Work in progress.
Walter, J. P., McGahan, J. P., & Lantz, B. M. T. (1986) · Radiology · doi:10.1148/radiology.159.2.3515426 · Cited by 27
Cited by
Atherosclerotic Vascular Disease Conference: Writing Group III: Pathophysiology
Faxon, D. P., Fuster, V., Libby, P., Beckman, J. A., Hiatt, W. R., Thompson, R. W., Topper, J. N., Annex, B. H., Rundback, J. H., Fabunmi, R. P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000128520.37674.ef · Cited by 414
Fetal and umbilical Doppler ultrasound in normal pregnancy
Alfirevic, Z., Stampalija, T., & Medley, N. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001450.pub4 · Cited by 198
Ultrasound-Based Micro-/Nanosystems for Biomedical Applications
Huang, H., Zheng, Y., Chang, M., Song, J., Xia, L., Wu, C., Jia, W., Ren, H., Feng, W., & Chen, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00009 · Cited by 183
Metadata
- Authors
- Nelson, T., & Pretorius, D.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1988-09-01
- Volume
- 151
- Issue
- 3
- Pages
- 439-447
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1964767329
- Cited by
- 249
- References
- 9
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.