CoChat
Cited by 304

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

MR imaging of brain abscesses

Haimes, AB, Zimmerman, RD, Morgello, S, Weingarten, K, Becker, RD, Jennis, R, Deck, MD · 1989 · American Journal of Roentgenology

Abstract

The MR images and CT scans of 14 patients with surgically verified pyogenic cerebral abscesses were reviewed. The MR findings correlated well with those seen on CT and were believed to be sufficiently characteristic to allow early and accurate diagnosis with MR alone. These features include (1) peripheral edema producing mild hypointensity on short TR/short TE and marked hyperintensity on long TR/intermediate to long TE scans; (2) central necrosis with abscess fluid hypointense relative to white matter and hyperintense relative to CSF on short TR/short TE scans and hyperintense relative to gray matter on long TR/intermediate to long TE scans (the fluid had concentric zones of varying intensity in seven cases, a finding not previously identified in other lesions); (3) extraparenchymal spread (intraventricular or subarachnoid), which was detected more easily on MR than on CT and was manifested by increased intensity relative to normal CSF on both short TR/short TE and long TR/intermediate TE scans; and (4) visualization of the abscess capsule, which was iso- to mildly hyperintense relative to brain on short TR/short TE scans and iso- to hypointense relative to white matter on long TR/intermediate to long TE scans. On the long TR scans, the relative hypointensity of the rim allowed for visualization of the typical morphologic features of the capsule, which in turn aided in differentiation of abscesses from other lesions (as it does on CT). To investigate the cause of the capsular intensity, pathologic studies of the capsules were reviewed when available (10 cases). Fibrosis was identified in all mature abscess capsules, but the combination of the intensities seen on short TR/short TE and long TR/intermediate to long TE scans as well as the temporal changes in intensity were believed to be incompatible with fibrosis as a cause of the capsular changes. Intensity patterns were suggestive of hemorrhage, but neither acute nor chronic hemorrhage was identified on routine H and E stains, while iron stain revealed scant hemorrhage in only two of the eight patients in whom these stains were used. We believe the capsular intensity (in particular the hypointense rims on long TR scans) may reflect paramagnetic T1, and to a greater extent T2, shortening, possibly due to the presence of heterogeneously distributed free radicals that are products of the respiratory burst produced by actively phagocytosing macrophages in the capsule wall. Distinctive MR features of pyogenic abscesses should afford early and accurate diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.152.5.1073

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Haimes, A., Zimmerman, R., Morgello, S., Weingarten, K., Becker, R., Jennis, R., & Deck, M.
Venue
American Journal of Roentgenology
Published
1989-05-01
Volume
152
Issue
5
Pages
1073-1085
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2052283736
Cited by
304
References
5
FWCI
10.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.