CoChat

The effect of high- vs low-density barium preparations on the quantitative features of swallowing

Dantas, RO, Dodds, WJ, Massey, BT, Kern, MK · 1989 · American Journal of Roentgenology
Cited by 122

The DOI matches its Crossref record.

Abstract

We compared the effect of high-density and low-density barium preparations on the quantitative features of swallowing. The two barium preparations differed primarily in density but also differed somewhat in viscosity. Concurrent videofluoroscopic and manometric studies were done in nine healthy control subjects. Videofluoroscopy was recorded in the lateral projection at 30 frames/sec while concurrent manometry was done with five intraluminal transducers that straddled the pharynx and upper esophageal sphincter. Swallows of 5 and 10 ml of high- and low-density barium preparations were recorded. Analysis indicated that, compared with the low-density barium (1.4 g/cm3), the high-density barium (2.5 g/cm3) preparation had a slower oral and pharyngeal bolus transit time and caused significant quantitative differences in the function of the upper esophageal sphincter. Compared with low-density barium boluses, the high-density barium boluses were associated with later sphincter opening and closure, longer duration of sphincter opening and flow, lower flow rate, greater maximal anterior hyoid movement, greater sagittal sphincter diameter, and higher intrabolus pressure upstream of and within the sphincter. We conclude that the density as well as the viscosity of the barium preparation used in radiologic examination of the oral-pharyngeal phases of swallowing has an influence on bolus transit time through the mouth and pharynx, and on the quantitative features of upper esophageal sphincter opening. Although these quantitative differences cannot generally be recognized visually at fluoroscopy, they become important for the quantitative assessment of swallowing in patients with suspected disorders of oral-pharyngeal swallowing. Therefore, the basic barium preparations used to examine such patients should be either standardized or at least specified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.153.6.1191

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Dantas, R., Dodds, W., Massey, B., & Kern, M.
Venue
American Journal of Roentgenology
Published
1989-12-01
Volume
153
Issue
6
Pages
1191-1195
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1996347136
Cited by
122
References
0
FWCI
3.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of high- vs low-density barium preparations on the quantitative features of swallowing. https://app.cochat.ai/papers/10.2214/ajr.153.6.1191
The paper
Dantas, R., Dodds, W., Massey, B., & Kern, M. (1989). The effect of high- vs low-density barium preparations on the quantitative features of swallowing. American Journal of Roentgenology. https://doi.org/10.2214/ajr.153.6.1191

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.