The DOI matches its Crossref record.
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Abstract
Superparamagnetic iron oxide (SPIO) particles are a potent new class of MR contrast agents affording improved detection of hepatic and splenic neoplasms. In this report we review the development of this agent through preclinical studies and early clinical results at Massachusetts General Hospital during a 5-year investigation. SPIO particles are sequestered by normal phagocytic Kupffer cells of the reticuloendothelial system (RES) but are not retained in tumor tissue. Consequently, there is a fivefold increase in T2 relaxation between normal RES tissue and tumor, with a comparable advantage in quantitative signal-to-noise ratio, contrast-to-noise ratio, and lesion detectability in the liver and spleen on MR imaging. Increased lesion conspicuity can be exploited to decrease threshold size for lesion detection to less than 3 mm. Clinically beneficial effects occur with a variety of mildly T2-weighted spin-echo pulse sequences; gradient-echo techniques show even greater benefit after administration of SPIO. Metabolically, pharmaceutical-grade preparations are biodegradable and bioavailable, being rapidly turned over into body iron stores and incorporated into erythrocyte hemoglobin. Early dose-escalation clinical trials have identified a probable clinical dose range of 10-20 mumols Fe/kg body weight. In the United States, SPIO compounds evaluated to date are still approved for use in investigational studies only. Newer commercial formulations currently being evaluated may extend clinical safety margins.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to their high liver uptake, iron oxide nanoparticles have been employed relatively extensively for visualizing primary lesions in the liver, e.g. in case of hepatocellular carcinoma (HCC) (Figure 3 A, B) as well as liver metastases (Figure 3 C, D) [144, 145].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [145]
Citations
Cited by
Sorted by citations
Items 101–200 of 279
Distinguishing splenosis from renal masses using ferumoxide-enhanced magnetic resonance imaging
Berman, A. J., Zahalsky, M. P., Okon, S., et al. (2003) · Urology · doi:10.1016/s0090-4295(03)00509-0 · Cited by 47
MR and Iron Magnetic Nanoparticles. Imaging Opportunities in Preclinical and Translational Research
Neumaier, C. E., Baio, G., Ferrini, S., Corte, G., & Daga, A. (2008) · Tumori Journal · doi:10.1177/030089160809400215 · Cited by 46
MR Imaging of Hypervascular Lesions in the Cirrhotic Liver: A Diagnostic Dilemma
Parente, D. B., Perez, R. D. M., EIRAS-ARAUJO, A. L., et al. (2012) · Radiographics · doi:10.1148/rg.323115131 · Cited by 44
MR Imaging of the Arterial Vessel Wall: Molecular Imaging from Bench to Bedside
Makowski, M. R., & Botnar, R. M. (2013) · Radiology · doi:10.1148/radiol.13102336 · Cited by 45
Magnetic core–shell nanowires as MRI contrast agents for cell tracking
Martínez-Banderas, A. I., Aires, A., Plaza‐García, S., Colás, L., Moreno, J. A., Ravasi, T., Merzaban, J. S., Ramos‐Cabrer, P., Cortajarena, A. L., & Kosel, J. (2020) · Journal of Nanobiotechnology · doi:10.1186/s12951-020-00597-3 · Cited by 46
Kubaska, S., Sahani, D. V., Saini, S., et al. (2001) · Clinical Radiology · doi:10.1053/crad.2000.0673 · Cited by 44
Gellissen, J., Axmann, C., Prescher, A., et al. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00206-9 · Cited by 43
LIVER II: IRON OXIDE-BASED RETICULOENDOTHELIAL CONTRAST AGENTS FOR MR IMAGING
Petersein, J., Saini, S., & Weissleder, R. (1996) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00553-5 · Cited by 43
Gadoxetate acid-enhanced MR imaging for HCC: A review for clinicians
Chanyaputhipong, J., Low, S.-C. A., & Chow, P. K. H. (2011) · International Journal of Hepatology · doi:10.4061/2011/489342 · Cited by 41
CT and MR imaging of hepatocellular carcinoma
Bolog, N. V., Andreisek, G., Oancea, I., et al. (2011) · PubMed · doi:10.5167/uzh-51213 · Cited by 41
Shape-dependent cellular behaviors and relaxivity of iron oxide-based T 1 MRI contrast agents
Sherwood, J. A., Lovas, K., Rich, M. C., Yin, Q., Lackey, K., Bolding, M., & Bao, Y. (2016) · Nanoscale · doi:10.1039/c6nr06158c · Cited by 41
Fujita, M., Yamamoto, R., Fritz‐Zieroth, B., Yamanaka, T., Takahashi, M., Miyazawa, T., Tatsuta, M., Terada, N., Hosomi, N., Inoue, E., et al. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060310 · Cited by 39
Superparamagnetic iron oxide: Detection of focal liver lesions at high‐field‐strength MR imaging
Duda, S. H., Laniado, M., Kopp, A. F., et al. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040314 · Cited by 40
In Vivo Fate of Avidin-Nucleic Acid Nanoassemblies as Multifunctional Diagnostic Tools
Bigini, P., Previdi, S., Casarin, E., Silvestri, D., Violatto, M. B., Facchin, S., Sitia, L., Rosato, A., Zuccolotto, G., Realdon, N., et al. (2013) · ACS Nano · doi:10.1021/nn402669w · Cited by 39
Mergo, P. J., Engelken, J. D., Helmberger, T. K., et al. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080511 · Cited by 38
“Recently, the FDA has approved SPIO particles, and USPIO particle preparations are in the phase II/III clinical trial stage of development (1-15).”
BackgroundSchultz, J. F., Bell, J. D., Goldstein, R. M., et al. (1999) · Annals of Surgical Oncology · doi:10.1007/pl00021736 · Cited by 37
Okada, M., Imai, Y., Kim, T., et al. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22333 · Cited by 36
“SPIO acts as a negative contrast agent because SPIO particles are taken up by Kupffer cells in the reticuloendothelial system of the liver (5,6), causing local magnetic field inhomogeneity and resulting in considerable T2* shortening (6).”
BackgroundFerrucci, J. T. (1994) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)00336-0 · Cited by 36
Self-citationMuehe, A. M., Theruvath, A. J., Lai, L. M., Aghighi, M., Quon, A. S. W., Holdsworth, S. J., Wang, J., Luna‐Fineman, S., Marina, N. M., Advani, R. H., et al. (2017) · Molecular Imaging and Biology · doi:10.1007/s11307-017-1105-7 · Cited by 35
Evertsson, M., Kjellman, P., Cinthio, M., et al. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.3034 · Cited by 35
Rummeny, E., & Marchal, G. (1997) · Acta Radiologica · doi:10.1080/02841859709172392 · Cited by 35
Kalber, T. L., Smith, C. J., Howe, F. A., Griffiths, J. R., Ryan, A. J., Waterton, J. C., & Robinson, S. P. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000188025.66872.e4 · Cited by 34
“Both SPIO and USPIO particles are made up of an iron crystalline core that consists primarily of superparamagnetic iron (Fe(3) ) oxide and coated with a biocompatible coating such as dextran, carboxydextran, polyethylene glycol (PEG), or starch.(2,3) Although SPIO particles have an overall diameter of 50 to 1000 nm, U…”
BackgroundYamashita, Y., Yamamoto, H., Hirai, A., et al. (1996) · Abdominal Imaging · doi:10.1007/s002619900072 · Cited by 34
“Reportedly, AMI-25 shows a blood clearance halflife of about 10 min, with uptake by hepatic Kupffer cells accounting for 80% of the injected dose [8].”
BackgroundVegerhof, A., Barnoy, E. A., Motiei, M., Malka, D., Danan, Y., Zalevsky, Z., & Popovtzer, R. (2016) · Materials · doi:10.3390/ma9110943 · Cited by 35
“Superparamagnetic iron oxide MNPs, which are T2 contrast agents, reduce longitudinal (T1) and transverse (T2) magnetic relaxation time of non-bonded (water) protons, yielding a dark negative signal intensity in MRI images [27].”
BackgroundMagnetic-Assisted Treatment of Liver Fibrosis
Levada, K. V., Omelyanchik, A. S., Rodionova, V. V., Weiskirchen, R., & Bartneck, M. (2019) · Cells · doi:10.3390/cells8101279 · Cited by 33
Hekimoğlu, K., Üstündağ, Y., Duşak, A., et al. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.09.002 · Cited by 33
Granot, D., Kunz‐Schughart, L. A., & Neeman, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20628 · Cited by 33
“Superparamagnetic iron oxide (SPIO) particles have been used both clinically (28) and in research studies of various biological processes, such as the detection of stem cells, tumor cells, and tumor-associated macrophages; migration and homing of stem cells to bone marrow, lymphocytes in the liver, spleen, and pancrea…”
BackgroundFerritin reporter used for gene expression imaging by magnetic resonance
Ono, K., Fuma, K., Tabata, K., & Sawada, M. (2009) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2009.08.055 · Cited by 32
Nanomaterials: promising structures for the management of oral cancer
Eskiizmir, G., Ermertcan, A. T., & Yapıcı, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-47720-8.00018-3 · Cited by 37
Trillaud, H., Grenier, N., Degrèze, P., Louail, C., Chambon, C., & Franconi, J. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030115 · Cited by 31
Non‐invasive detection of transplanted pancreatic islets
Medarova, Z. O., & Moore, A. V. (2008) · Diabetes Obesity and Metabolism · doi:10.1111/j.1463-1326.2008.00942.x · Cited by 31
Molecular MRI of Atherosclerosis
Phinikaridou, A., Andía, M. E., Lacerda, S., Lorrio, S., Makowski, M. R., & Botnar, R. M. (2013) · Molecules · doi:10.3390/molecules181114042 · Cited by 30
“In more advanced atherosclerotic lesions new blood vessels start developing, preferentially in the adventitia [58,102,103].”
BackgroundJanic, B., Iskander, A., Rad, A. M., Hamid Soltanian-zadeh, A., & Arbab, A. S. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002499 · Cited by 29
“intravenous MRI contrast agent for analyzing the liver pathology [1], but also as an ex vivo cell labeling agent for various types of mammalian cells that when labeled can be utilized as an in vivo MRI probes.”
Asahina, Y. (2003) · Hepatology Research · doi:10.1016/s1386-6346(03)00261-4 · Cited by 29
Kojima, H., Mukai, Y., Yoshikawa, M., Kamei, K., Yoshikawa, T., Morita, M., Inubushi, T., Yamamoto, T. A., Yoshioka, Y., Okada, N., et al. (2010) · Bioconjugate Chemistry · doi:10.1021/bc900487p · Cited by 28
Hou, Y., Liu, Y., Chen, Z., et al. (2010) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-8-25 · Cited by 28
Advances in Applications of Metal Oxide Nanomaterials as Imaging Contrast Agents
Anderson, D. R., Anderson, T., & Fahmi, F. (2019) · physica status solidi (a) · doi:10.1002/pssa.201801008 · Cited by 26
Magnetic Nanoparticles for MR Imaging
Josephson, L. (2007) · Springer eBooks · doi:10.1007/978-0-387-25842-3_8 · Cited by 27
Contrast‐enhanced MR imaging of the liver
Runge, V. M., Rijcken, T. H. P., Davidoff, A., et al. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040311 · Cited by 27
Shiozawa, M., Kobayashi, S., Sato, Y., Maeshima, H., Hozumi, Y., Lefor, A. K., Kurihara, K., Sata, N., & Yasuda, Y. (2012) · Breast Cancer · doi:10.1007/s12282-012-0401-y · Cited by 26
“, their active uptake by normal lymph nodes results in a homogeneous decrease in signal intensity on T2-star (T2*)weighted images [3, 4, 7].”
BackgroundAspergillus in cytology specimens: A review of 45 specimens from 36 patients
Fischler, D. F., Hall, G. S., Gordon, S. M., Stoler, M. H., & Nuñez, C. (1997) · Diagnostic Cytopathology · doi:10.1002/(sici)1097-0339(199701)16:1 · Cited by 12
New Applications of Nanotechnology for Neuroimaging
Suffredini, G., East, J. E., & Levy, L. M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3543 · Cited by 30
“The SPIO nanoparticles are biocompatible and are degraded through the normal iron metabolism mechanisms in the body.(41) Clinical trials based on this approach include labeling and tracking of dendritic cells in immunotherapy of melanoma, autologous neural stem cells in traumatic head injury, bone marrow stem cells in…”
BackgroundThe Application of Nanotechnology to Drug Delivery in Medicine
McDonald, T. O., Siccardi, M., Moss, D. M., Liptrott, N. J., Giardiello, M., Rannard, S. P., & Owen, A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-444-62747-6.00007-5 · Cited by 26
Koyama, T., Shimura, M., Minemoto, Y., et al. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.023 · Cited by 25
Lübbe, A. S., & Bergemann, C. (1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6_35 · Cited by 25
Historical Perspective of Imaging Contrast Agents
Zamora, C. A., & Castillo, M. (2017) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2017.06.002 · Cited by 24
Dupas, B., Berreur, M., Rohanizadeh, R., et al. (1999) · Biology of the Cell · doi:10.1016/s0248-4900(99)80042-2 · Cited by 24
Dieckhoff, J., Kaul, M. G., Mummert, T., Jung, C., Salamon, J., Adam, G., Knopp, T., Ludwig, F., Balceris, C., & Ittrich, H. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa562d · Cited by 23
Canet‐Soulas, E., Revel, D., Sebbag, L., de Lorgeril, M., Baldy, C., Delabre, C., & AMIEL, M. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90193-0 · Cited by 21
A small-scale anatomical dosimetry model of the liver
Stenvall, A., Larsson, E., Strand, S., & Jönsson, B.-A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/13/3353 · Cited by 23
“After intravenous injection the SPIONs are removed from the circulation by the mononuclear phagocytic system, including the Kupffer cells in the liver (Ferrucci and Stark 1990).”
BackgroundCT versus MR Imaging of Hepatocellular Carcinoma: Toward Improved Treatment Decisions
Murakami, T., Okada, M., & Hyodo, T. (2012) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.11.75 · Cited by 22
Hundt, W., Petsch, R., Helmberger, T. K., & Reiser, M. F. (2000) · European Radiology · doi:10.1007/s003300050067 · Cited by 22
“After intravenous administration of SPIO particles, the liver parenchyma shows a loss of signal intensity due to accumulation of 80% of the SPIO particles by the Kupffer cells [4].”
BackgroundHepatic MR Imaging Using Ferumoxides
Raman, S. S., Lu, D., Chen, S. C., et al. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.4.1770807 · Cited by 22
Trillaud, H., Degrèze, P., Mesplède, Y., et al. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80187-4 · Cited by 21
Tracking stem cell migration and survival in brain injury: current approaches and future prospects.
Darkazalli, A., & Levenson, C. W. (2012) · PubMed · doi:10.14670/hh-27.1255 · Cited by 21
Developments for the minimally invasive treatment of tumours by targeted magnetic heating
Hilger, I., Dietmar, E. M., Linß, W., Streck, S., & Kaiser, W. A. (2006) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/18/38/s28 · Cited by 21
Magnetic Resonance Imaging: Utility as a Molecular Imaging Modality
Basilion, J. P., Yeon, S. B., & Botnar, R. M. (2005) · Current topics in developmental biology/Current Topics in Developmental Biology · doi:10.1016/s0070-2153(05)70001-6 · Cited by 20
Bellenger, N. G., Gatehouse, P. D., Rajappan, K., Keegan, J., Firmin, D. N., & Pennell, D. J. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200004)11:4 · Cited by 36
Birnbaum, B. A., Weinreb, J. C., Fernandez, M. P., et al. (1994) · Clinical Imaging · doi:10.1016/0899-7071(94)90141-4 · Cited by 20
Ex-vivo cellular MRI with b-SSFP: quantitative benefits of 3 T over 1.5 T
Ramadan, S. S., Heyn, C., MacKenzie, L. T., Chambers, A. F., Rutt, B. K., & Foster, P. J. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0118-2 · Cited by 19
“Some pathologies studied using this approach include hepatic neoplasia [12], lymphatic metastasis [13,14], atherosclerosis [15], myocardial infarction [16], multiple sclerosis [17,18] and spinal cord”
BackgroundRecent advances in imaging hepatic fibrosis and steatosis
Patel, K. D., Abeysekera, K. W. M., Marlais, M., McPhail, M. J. W., Thomas, H. C., Fitzpatrick, J. A., Lim, A. K. P., Taylor-Robinson, S. D., & Thomas, E. L. (2011) · Expert Review of Gastroenterology & Hepatology · doi:10.1586/egh.10.85 · Cited by 18
Li, Z., Qin, X.-Y., Guo, L.-Y., Wang, H., Liu, X., Zheng, Z., Guan, H., Song, L., Zou, Y., & Fan, T. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.04.069 · Cited by 19
MR Angiography with Superparamagnetic Iron Oxide: Feasibility Study
Schmitz, S. A., Albrecht, T., & Wolf, K.-J. (1999) · Radiology · doi:10.1148/radiology.213.2.r99oc24603 · Cited by 19
Baio, G., Fabbi, M., de Totero, D., et al. (2006) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-006-0059-6 · Cited by 19
“An important property of USPIO is the strong T2 relaxivity that produces a decrease in signal intensity (SI) on T2-weighted images [2,3] and also a high T1 relaxivity with an increase of SI on T1-weighted images [4,5].”
BackgroundSantoro, L., Grazioli, L., Filippone, A., Grassedonio, E., Belli, G., & Colagrande, S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21937 · Cited by 18
“Classification of benign (1) versus malignant (0) lesions on T2-weighted images.”
BackgroundMethodBaio, G., Fabbi, M., Salvi, S., et al. (2009) · Molecular Imaging and Biology · doi:10.1007/s11307-009-0264-6 · Cited by 18
“Important properties of USPIO are the strong T2 relaxivity that produces a decrease in signal intensity (SI) on T2-weighted images [4, 5] and high T1 relaxivity that causes an increase in SI on T1-weighted images [6, 7].”
BackgroundFunctional MR Imaging Techniques in Oncology in the Era of Personalized Medicine
Benz, M., Vargas, H. A., & Sala, E. (2015) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2015.08.001 · Cited by 18
Zhang, J., Idiyatullin, D., Corum, C. A., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25595 · Cited by 18
“[3] represents the solution for a continuous B1 field, it is also suitable for gapped excitation for the given bandwidth as long as the RF power and sampling requirements are met (32).”
BackgroundBaraki, H., Zinne, N., Wedekind, D., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051770 · Cited by 18
“Iron oxide released from cells due to other mechanisms could also result in a similar signal [41].”
BackgroundThe characterization of liver tumours by MRI
Robinson, P. J. A. (1996) · Clinical Radiology · doi:10.1016/s0009-9260(96)80002-x · Cited by 17
Macarini, L., Marini, S., Milillo, P., et al. (2006) · La radiologia medica · doi:10.1007/s11547-006-0107-3 · Cited by 16
SPIO-MRI in the detection of hepatocellular carcinoma
Araki, T. (2000) · Journal of Gastroenterology · doi:10.1007/s005350070028 · Cited by 16
Hirohashi, S., Ueda, K., Uchida, H., et al. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv26415 · Cited by 16
Frate, C. D., Zuiani, C., Londero, V., et al. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.5.1801339 · Cited by 16
Wang, H., Qin, X.-Y., Li, Z., Guo, L.-Y., Zheng, Z., Liu, L.-S., & Fan, T. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.07.028 · Cited by 15
“Moreover, the superparamagnetism of SPIO nanoparticles was associated with its crystalline structure which could facilitate the alignment of adjoining spins to the external magnetic fields (Ferrucci and Stark, 1990).”
BackgroundInfluentialLakić, M., Andjelković, L., Šuljagić, M., Vulić, P. J., Perić, M., Iskrenović, P., Krstić, I., Kuraica, M. M., & Nikolić, A. S. (2019) · Optical Materials · doi:10.1016/j.optmat.2019.03.031 · Cited by 14
Berger, C., Rausch, M., Schmidt, P., et al. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00010 · Cited by 15
“In the rat EAE model, the use of USPIOs, initially developed for imaging of the liver lesions [5], provided an almost 100% sensitivity for lesion detection [6].”
MethodWang, Z., Wang, L., Tang, B., et al. (2007) · Surgical Endoscopy · doi:10.1007/s00464-007-9716-8 · Cited by 15
A case of hepatic angiomyolipoma difficult to distinguish from hepatocellular carcinoma
Takahara, M., Miyake, Y., Matsumoto, K., et al. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.2930 · Cited by 14
Dual contrast magnetic resonance imaging tracking of iron-labeled cells in vivo
Wu, S. Y., Zhang, L., Zhong, J., & Zhang, Z. (2010) · Cytotherapy · doi:10.3109/14653241003587652 · Cited by 14
Controlled synthesis of shell cross-linked magnetic micelles for efficient liver MR imaging
Niu, D., Zhang, Z., Jiang, S., Ma, Z., Liu, X., Li, Y., Zhou, L., Liu, C., Li, Y., & Shi, J. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm35308c · Cited by 14
Alger, J. R., Harreld, J. H., Chen, S. C., Mintorovitch, J., & Lu, D. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1223 · Cited by 14
“(2) Signal-to-noise measures suggested that SPIO reduced the lesion signal.”
BackgroundMagnetic Resonance Imaging of Diseases of the Liver and Biliary System
Kanzer, G. K., & Weinreb, J. C. (1991) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02477-0 · Cited by 14
Molecular Imaging With Targeted Contrast Agents
Makowski, M. R., Wiethoff, A. J., Jansen, C. H. P., & Botnar, R. M. (2009) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181ea28b1 · Cited by 13
“Superparamagnetic iron oxide (SPIO) particles producemuch stronger effect in 1 / T2 than in 1 / T1, so they are best displayedwith T2-weighted scans.(42) Superparamagnetic iron oxide particles produce a marked disturbance in surrounding magnetic field homogeneity, especially apparent when an inhomogeneous distribution…”
BackgroundMesenchymal stem cell tracking in the intervertebral disc
Handley, C. (2015) · World Journal of Stem Cells · doi:10.4252/wjsc.v7.i1.65 · Cited by 13
Deckers, F., Corthouts, B., Nackaerts, Y., et al. (1997) · European Radiology · doi:10.1007/s003300050222 · Cited by 13
“In recent years the issue of image quality related to field strength in general, and the effect of field strength on SPIO in particular, have been the subject of discussion [1, 4, 7].”
BackgroundLeander, P., Golman, K., Månsson, S., et al. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181e960ab · Cited by 12
“It has been shown in both experimental and clinical studies that CNR correlates with tumor detection-rates.(8,28) As there are no focal lesions in the livers of healthy volunteers, the spleen was used as an internal phantom because its signal characteristics is similar to such lesions.”
BackgroundYoshiokaa, H., Itai, Y., Saida, Y., et al. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00192-2 · Cited by 12
CT and MR Imaging of the Liver Using Liver-Specific Contrast Media
Leander, P., Månsson, S., Ege, T., et al. (1996) · Acta Radiologica · doi:10.1177/02841851960371p155 · Cited by 12
“Since they induce magnetic field unhomogeneities, the signal in the proximity of these particles is lost (5, 7).”
BackgroundFahmy, H. M., El‐Daim, T. M. A., Mohamed, H. A. A. E., Mahmoud, E. A. A. E. Q., Abdallah, E. A. S., Hassan, F. E.-Z. M., Maihop, D. I., Amin, A. E. A. E., Mustafa, A. B. E.-D., Hassan, F. E.-Z. M., et al. (2020) · Tissue and Cell · doi:10.1016/j.tice.2020.101371 · Cited by 11
Effect of HSA coated iron oxide labeling on human umbilical cord derived mesenchymal stem cells
Sanganeria, P., Chandra, S., Bahadur, D., & Khanna, A. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/12/125103 · Cited by 12
Molecular Imaging in Cardiovascular Diseases
Botnar, R. M., Ebersberger, H. U., Noerenberg, D., Jansen, C. H. P., Wiethoff, A. J., Schuster, A., Kasner, M., Walter, T., Knobloch, G., Höppe, P., et al. (2015) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0034-1385451 · Cited by 13
“Therefore SPIO particles can be most sensitively visualized using T2 or T2*-weighted sequences [40].”
Chen, J., Jia, Z., Ma, Z., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020790 · Cited by 10
“It was considered that any SPIO released into the blood would be taken up by the Kupffer cells in the liver and in the reticuloendothelial system in the spleen [32,33].”
BackgroundChung, Y. E., Park, M., Kim, M. S., Kim, E., Park, J., Song, H., Choi, J., Kim, M., & Kim, K. W. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22184 · Cited by 10
Sugihara, S., Suto, Y., Kamba, M., et al. (2001) · Clinical Imaging · doi:10.1016/s0899-7071(01)00252-2 · Cited by 10
“Many studies have recently reported that the use of iron colloid preparations as reticuloendothelial negative MR contrast agents for diagnosing hepatic tumors improves diagnostic capacity [8–14].”
BackgroundHuang, M., Qiao, Z., Miao, F., Jia, N., & Shen, H. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0210-y · Cited by 9
“It is well-known that magnetic nanoparticles are usually taken up by the liver and spleen [39, 40], and in our study the signal intensity of the liver and spleen have indeed decreased after injection of biofunctional magnetic nanoparticles.”
BackgroundBiofunctionalized Mesoporous Silica Nanomaterials for Targeted Drug Delivery
Rahikkala, A., Rosenholm, J. M., & Santos, H. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-50878-0.00016-1 · Cited by 10
Mykhaylyk, O. M., Razumov, O. N., Dudchenko, A. K., Pankratov, Y. V., Dobrinsky, E. K., Sosnitsky, V. N., & Bakai, E. A. (1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6_14 · Cited by 9
Furman‐Haran, E., Margalit, R., Grobgeld, D., et al. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080318 · Cited by 9
Ferumoxytol-enhanced MR imaging for differentiating intrapancreatic splenules from other tumors
Mühler, M. R., Rendell, V. R., Bergmann, L. L., Winslow, E. R., & Reeder, S. B. (2020) · Abdominal Radiology · doi:10.1007/s00261-020-02883-y · Cited by 8
Metadata
- Authors
- Ferrucci, J. T., & Stark, D. D.
- Affiliations
- Massachusetts General Hospital (US)
- ORCID
- Stark, D D
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1990-11
- Volume
- 155
- Issue
- 5
- Pages
- 943-950
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2068366961
- Cited by
- 279
- References
- 0
- Citations by year
- 2025: 4 · 2024: 5 · 2023: 6 · 2022: 4 · 2021: 2 · 2020: 6 · 2019: 6 · 2018: 7 · 2017: 11 · 2016: 6 · 2015: 18 · 2014: 9 · 2013: 10 · 2012: 18
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- superparamagnetic iron oxide nanoparticles, MRI contrast agents, liver tumors, splenic neoplasms, Kupffer cells, T2 relaxation, tumor detection, reticuloendothelial system, dose escalation, contrast-to-noise ratio, gradient-echo imaging, iron metabolism
- MeSH terms
- Animals, Humans, Image Enhancement, Iron, Liver Diseases, Magnetic Resonance Imaging, Oxides, Splenic Neoplasms, Ferrosoferric Oxide
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review