Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation.
The DOI matches its Crossref record.
Abstract
The accuracy of measurements of flow velocity determined by using cine MR phase velocity mapping--velocity-encoded cine (VEC) MR--was assessed by comparing VEC MR data with independent measurements in a flow phantom and in human subjects. Constant flow velocities generated in a phantom (range, 20-408 cm/sec) were determined correctly by VEC MR (r = .997, standard error of the estimate [SEE] = 7.9 cm/sec). Peak systolic velocities in the main pulmonary artery determined by VEC MR correlated well with the measurements obtained by using continuous-wave Doppler echocardiography (r = .91). Stroke volumes measured at the aorta by VEC MR and continuous-wave Doppler imaging also correlated well with each other (r = .80). VEC MR measurements of aortic and pulmonary flow provided left and right ventricular stroke volumes that correlated well with left ventricular stroke volumes determined by short-axis cine MR images (r = .98, SEE = 3.7 ml, and r = .95, SEE = 4.8 ml, respectively). Intra- and interobserver variabilities were small for both left and right ventricular stroke volumes as measured with VEC MR. These results indicate that VEC MR accurately and reproducibly measures aortic and pulmonary flow velocities and volumes in the physiologic range of humans, and can be used to measure right and left ventricular stroke volumes under normal flow conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma11651 · Cited by 673
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Self-citationCardiovascular Magnetic Resonance Imaging for Valvular Heart Disease: Technique and Validation
Cawley, P. J., Maki, J. H., & Otto, C. M. (2009) · Circulation · doi:10.1161/circulationaha.107.742486 · Cited by 260
Helbing, W. A., Niezen, R. A., Le Cessie, S., Van Der Geest, R. J., Ottenkamp, J., & De Roos, A. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00387-7 · Cited by 239
Buechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Powell, A. J., Maier, S. E., Chung, T., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910014 · Cited by 207
“Several authors demonstrated close agreement between ventricular stroke volume obtained by PVC MRI and that obtained by subtracting end systolic volume from end diastolic volume [4, 11, 20, 28, 34].”
BackgroundQuantification of mitral regurgitation by velocity-encoded cine nuclear magnetic resonance imaging
Fujita, N., Chazouilleres, A. F., Hartiala, J. J., O'sullivan, M., Heidenreich, P., Kaplan, J. D., Sakuma, H., Foster, E., Caputo, G. R., & Higgins, C. B. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90642-4 · Cited by 198
Self-citationReproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass
Pattynama, P. M. T., Lamb, H. J., Van der Velde, E. A., Van der Geest, R. J., Van der Wall, E. E., & De Roos, A. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00076-f · Cited by 193
Helbing, W. A., Rebergen, S. A., Maliepaard, C., Hansen, B., Ottenkamp, J., Reiber, J. H. C., & de Roos, A. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90084-5 · Cited by 181
Clough, R. E., Waltham, M., Giese, D., Taylor, P. R., & Schaeffter, T. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.11.005 · Cited by 159
Ficial, B., Finnemore, A. E., Cox, D. J., Broadhouse, K. M., Price, A. N., Durighel, G., Ekitzidou, G., Hajnal, J. V., Edwards, A. D., & Groves, A. M. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.08.019 · Cited by 102
Cardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
Norton, K. I., Tong, C., Glass, R. B. J., & Nielsen, J. C. (2006) · RadioGraphics · doi:10.1148/rg.261055064 · Cited by 67
Metadata
- Authors
- Kondo, C., Caputo, G. R., Semelka, R., Foster, E., Shimakawa, A., & Higgins, C. B.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1991-07
- Volume
- 157
- Issue
- 1
- Pages
- 9-16
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1979097847
- Cited by
- 260
- References
- 0
- FWCI
- 12.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.