Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography.

Kent, D L, Haynor, D R, Larson, E B, Deyo, R A·1992·American Journal of Roentgenology

Abstract

We undertook a literature synthesis of CT, MR, and myelographic studies to evaluate what is known about the diagnostic accuracy of these imaging tests for the diagnosis of lumbar spinal stenosis in adults without prior surgery. From 116 possibly relevant studies, we reviewed 14 articles that included cases of spinal stenosis with a reference standard other than the imaging tests of interest. Of the studies we reviewed, two involved only MR, nine only CT, and three used both; six studies included myelography. Rating categories of A, B, C, or D were assigned for the quality of research methods used to estimate diagnostic accuracy. All studies received either a C or D rating. Common methodologic problems were failure to assemble a representative cohort for study, small sample size, and failure to maintain independence between image readings and reference standards. Sensitivity ranged from 0.81 to 0.97 for MR, from 0.70 to 1.0 for CT, and from 0.67 to 0.78 myelography. Studies varied greatly in case selection, definition of test and disease categories, and geographic locale, so no pooled estimates could be derived. In asymptomatic patients, abnormal findings appeared on CT or MR in 4-28% of cases and were more common in the elderly. Published studies of the value of CT and MR for the diagnosis of lumbar stenosis lack methodologic rigor and do not permit strong conclusions about the relative diagnostic accuracies of these procedures. For the present, the choice between MR or CT depends on issues such as costs, reimbursements, access to equipment, skill of radiologists, and patient safety. Better studies will be needed to document claims for improvements in imaging accuracy as MR technologies evolve. These studies should emphasize larger sample sizes, more attention to research designs that avoid methodologic biases, and the contribution of imaging diagnoses to ultimate clinical outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.158.5.1533084

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 219

Metadata

Authors
Kent, D. L., Haynor, D. R., Larson, E. B., & Deyo, R. A.
Venue
American Journal of Roentgenology
Published
1992-05
Volume
158
Issue
5
Pages
1135-1144
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2071887399
Cited by
219
References
1
FWCI
2.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography. https://app.cochat.ai/papers/10.2214/ajr.158.5.1533084
The paper
Kent, D. L., Haynor, D. R., Larson, E. B., & Deyo, R. A. (1992). Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography. American Journal of Roentgenology. https://doi.org/10.2214/ajr.158.5.1533084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.