Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

MR imaging of adrenal masses: value of chemical-shift imaging for distinguishing adenomas from other tumors.

Bilbey, J H, McLoughlin, R F, Kurkjian, P S, Wilkins, G E, Chan, N H, Schmidt, N, Singer, J·1995·American Journal of Roentgenology

Abstract

OBJECTIVE: CT and conventional MR imaging are helpful in characterizing adrenal tumors, but a specific diagnosis is not achieved for a substantial number of lesions. Chemical-shift imaging relies on the different resonance frequencies of protons in water and triglyceride molecules and therefore may permit a more specific diagnosis of adrenal adenomas, which are known to contain abundant lipid. The purpose of this study was to evaluate the usefulness of chemical-shift MR imaging in the differentiation of adrenal adenomas from other adrenal masses. SUBJECTS AND METHODS: Forty-one adrenal masses (17 nonhyperfunctioning adenomas, two aldosteronomas, six pheochromocytomas, one ganglioneuroma, five adrenal carcinomas, one lymphoma, seven metastases, one case of extramedullary hematopoiesis, and one leiomyosarcoma) suspected clinically or identified by sonography or CT in 38 patients were prospectively evaluated with MR imaging. Pathologic proof of diagnosis was obtained for 28 lesions, and stability on imaging follow-up (mean, 19 months) was accepted as proof of diagnosis of benign adenoma for 13 lesions. In-phase T1-weighted spin-echo sequences (500/20 [TR/TE]) and opposed-phase gradient-echo sequences (142/6.3, flip angle = 90 degrees) of the adrenal regions were applied. Quantitative analysis of signal intensity loss in the adrenal lesions relative to reference tissues (liver, muscle, and spleen) on in-phase and opposed-phase sequences was done to differentiate adenomas from nonadenomas. Region-of-interest signal intensity measurements were obtained in a standard fashion by selection of the largest possible representative sample. RESULTS: Using liver as the reference standard, we found that mean signal intensity ratios were 0.47 (range, 0.23-0.97) for adrenal adenomas and 0.88 (range, 0.65-1.32) for nonadenomas; signal intensity ratios for two adenomas overlapped those of the nonadenomas. Using muscle as the reference standard, we found that mean signal intensity ratios were 0.44 (range, 0.22-0.66) for adrenal adenomas and 0.85 (range, 0.59-1.39) for nonadenomas; signal intensity ratios for two adenomas overlapped those of the nonadenomas. Using spleen as the reference standard, we found that mean signal intensity ratios were 0.45 (range, 0.27-0.73) for adrenal adenomas and 0.97 (range, 0.8-1.18) for nonadenomas, with no overlap. The mean signal intensity ratios were significantly different between adenomas and nonadenomas for all three reference tissues (p < .001). CONCLUSION: Our results show that chemical-shift MR imaging is an important new technique that enables the differentiation of adrenal adenomas from other adrenal masses, reducing the need for biopsy and prolonged imaging follow-up in patients with adrenal tumors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.164.3.7863885

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Bilbey, J. H., McLoughlin, R. F., Kurkjian, P. S., Wilkins, G. E., Chan, N. H., Schmidt, N., & Singer, J.
Venue
American Journal of Roentgenology
Published
1995-03
Volume
164
Issue
3
Pages
637-642
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2114271353
Cited by
168
References
0
FWCI
9.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR imaging of adrenal masses: value of chemical-shift imaging for distinguishing adenomas from other tumors. https://app.cochat.ai/papers/10.2214/ajr.164.3.7863885
The paper
Bilbey, J. H., McLoughlin, R. F., Kurkjian, P. S., Wilkins, G. E., Chan, N. H., Schmidt, N., & Singer, J. (1995). MR imaging of adrenal masses: value of chemical-shift imaging for distinguishing adenomas from other tumors. American Journal of Roentgenology. https://doi.org/10.2214/ajr.164.3.7863885

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.