Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Characterization of adrenal masses (< 5 cm) by use of chemical shift MR imaging: observer performance versus quantitative measures.

Mayo-Smith, W W, Lee, M J, McNicholas, M M, Hahn, P F, Boland, G W, Saini, S·1995·American Journal of Roentgenology

Abstract

OBJECTIVE: The purposes of this study were to evaluate the ability of chemical shift MR imaging to differentiate 1- to 5-cm adrenal adenomas from metastases and to compare subjective interpretation with several different quantitative measures. SUBJECTS AND METHODS: Forty-three patients with 46 proved adrenal lesions (28 adenomas and 18 metastases) had MR imaging with a gradient-echo breath-hold technique and echo time varied to obtain in-phase and out-of-phase images. Qualitative analysis of the MR images was done by three experienced observers, who reported their confidence in diagnosing the benignity versus the malignancy of the adrenal masses on the basis of signal loss on out-of-phase images. Quantitative analysis was performed by calculating the difference in signal intensity between in-phase and out-of-phase images by use of regions of interest (signal intensity index) and by use of adrenal-liver, adrenal-spleen, and adrenal-muscle signal intensity ratios. Results between quantitative and qualitative measures were compared by use of receiver operating characteristic (ROC) analysis. RESULTS: The mean signal intensity was significantly different between adenomas and metastases on out-of-phase images (64 versus 98) (p < .0005) but not in-phase images (130 versus 122) (p = .47). The adrenal-spleen ratio discriminated between adenomas and metastases better than did the adrenal-liver ratio, the adrenal-muscle ratio, or the signal intensity index. No significant difference in interpretation among the three observers was evident (areas under the ROC curves, 0.93, 0.95, and 0.96). The performance of the observers was comparable to the results obtained with the adrenal-spleen ratio measurement (area under the ROC curve, 0.97). CONCLUSION: Experienced observers were able to differentiate adrenal adenomas from metastases just as well as quantitative measures. The adrenal-spleen ratio is the best quantitative means of distinguishing benign from malignant adrenal masses. Chemical shift MR imaging is a good but imperfect discriminator of adrenal adenomas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.165.1.7785642

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Mayo-Smith, W. W., Lee, M. J., McNicholas, M. M., Hahn, P. F., Boland, G. W., & Saini, S.
Venue
American Journal of Roentgenology
Published
1995-07
Volume
165
Issue
1
Pages
91-95
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2038458990
Cited by
215
References
1
FWCI
9.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of adrenal masses (< 5 cm) by use of chemical shift MR imaging: observer performance versus quantitative measures. https://app.cochat.ai/papers/10.2214/ajr.165.1.7785642
The paper
Mayo-Smith, W. W., Lee, M. J., McNicholas, M. M., Hahn, P. F., Boland, G. W., & Saini, S. (1995). Characterization of adrenal masses (< 5 cm) by use of chemical shift MR imaging: observer performance versus quantitative measures. American Journal of Roentgenology. https://doi.org/10.2214/ajr.165.1.7785642

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.