MR imaging of the fetus by a HASTE sequence.
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The value of a half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence, in which high-resolution heavily T2-weighted images can be obtained within 2 sec, was evaluated in the imaging of the fetus during the second or third trimester. MATERIALS AND METHODS: Eighteen women with complicated pregnancies as revealed on a sonogram during the second and third trimesters (16-36 weeks' gestation) were studied with a 1.5-T superconductive MR imaging unit that used a body phased-array coil. After informed consent, T1-weighted fast low-angle shot images, T2-weighted turbo spin-echo images, and HASTE images were obtained without any premedication. Images were analyzed with regard to image quality, degree of blurring, visualization of the normal fetal organs, and visualization of fetal and maternal abnormalities. RESULTS: On HASTE sequences, visualization of the fetal brain, visceral organs (lung, heart, liver, kidney, and bladder), extremities, and umbilical cord were significantly better than on fast low-angle shot or turbo spin-echo sequences (p < .01). In the brain, the white matter-gray matter distinction, gyrus formation, and myelination of the brain were clearly revealed by the HASTE sequence. Pathologic processes including fetal abnormalities (anomalies of the central nervous systems [n = 5], placenta previa [n = 1], and transverse lie in the third trimester [n = 1]) and maternal abnormalities (leiomyoma [n = 5], ovarian tumors [n = 3], and hydronephrosis [n = 1]) were clearly seen on HASTE imaging. The peak specific absorption rate for RF exposure in these studies was less than 1.5 W/kg. CONCLUSION: In situations when sonography is suggestive but not definitive, MR imaging with a HASTE sequence allows clear fetal imaging with high T2-weighted contrast.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Safety considerations in MR imaging.
Kanal, E., Shellock, F. G., & Talagala, L. (1990) · Radiology · doi:10.1148/radiology.176.3.2202008 · Cited by 302
The distribution of nuchal translucency at 10–13 weeks of pregnancy
Schuchter, K., Wald, N., Hackshaw, A. K., Hafner, E., & Liebhart, E. (1998) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199803)18:3<247::aid-pd253>3.0.co;2-j · Cited by 54
Cited by
Ohno, Y., Koyama, H., Yoshikawa, T., Seki, S., Takenaka, D., Yui, M., Lu, A., Miyazaki, M., & Sugimura, K. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25008 · Cited by 159
Maturation of the human fetal brain as observed by 1H MR spectroscopy
Kok, R. D., van den Berg, P. P., van den Bergh, A. J., Nijland, R., & Heerschap, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10264 · Cited by 129
Metadata
- Authors
- Yamashita, Y., Namimoto, T., Abe, Y., Takahashi, M., Iwamasa, J., Miyazaki, K., & Okamura, H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1997-02
- Volume
- 168
- Issue
- 2
- Pages
- 513-519
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2013541114
- Cited by
- 209
- References
- 2
- FWCI
- 17.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.