In-phase and out-of-phase MR imaging of bone marrow: prediction of neoplasia based on the detection of coexistent fat and water.
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to determine if gradient-echo MR imaging with TEs selected with fat and water in phase and out of phase can help predict the likelihood of neoplastic or nonneoplastic lesions in bone marrow. SUBJECTS AND METHODS: Thirty consecutive patients with 31 suspected bone marrow lesions underwent MR imaging, including two spoiled gradient-echo sequences identical in all parameters except TE, which was chosen such that fat and water were either in phase or out of phase. Relative ratios of the abnormal bone marrow signal intensity and a control site on the in-phase and out-of-phase images were expressed. The images were also assessed independently by two reviewers who were unaware of the patients' identities and clinical histories. Reviewers assessed decreased marrow signal intensity relative to control sites on the out-of-phase and in-phase images. Pathologic confirmation was obtained in 16 patients (17 lesions); the remainder of patients had either established diagnoses or determination of benignity based on stability of findings at 1 year. Relative ratios were compared with the Student's t test and receiver operating characteristic (ROC) curve analysis, and the reviewers' scores were evaluated with ROC curve analysis. RESULTS: The relative signal-intensity ratios were 1.03 +/- 0.13 for the neoplastic group and 0.62 +/- 0.13 for the nonneoplastic group (p < .0001). ROC curve analysis of the signal-intensity ratios showed a z-score of .99. A ratio cutoff value of 0.81 resulted in a 95% sensitivity and a 95% specificity for detection of neoplasm. Both reviewers achieved 100% sensitivity and 94-100% specificity for detection of neoplasms. CONCLUSION: In-phase and out-of-phase gradient-echo MR imaging of bone marrow signal-intensity abnormalities can help predict the likelihood of neoplastic or nonneoplastic lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874
Benign adrenocortical masses: diagnosis with chemical shift MR imaging.
Mitchell, D. G., Crovello, M., Matteucci, T., Petersen, R. O., & Miettinen, M. M. (1992) · Radiology · doi:10.1148/radiology.185.2.1410337 · Cited by 335
Red and yellow marrow in the femur: age-related changes in appearance at MR imaging.
Moore, S. G., & Dawson, K. L. (1990) · Radiology · doi:10.1148/radiology.175.1.2315484 · Cited by 332
Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging.
Tsushima, Y., Ishizaka, H., & Matsumoto, M. (1993) · Radiology · doi:10.1148/radiology.186.3.8430178 · Cited by 184
Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging.
Senéterre, E., Weissleder, R., Jaramillo, D., Reimer, P., Lee, A. S., Brady, T. J., & Wittenberg, J. (1991) · Radiology · doi:10.1148/radiology.179.2.2014305 · Cited by 109
Hematologic bone marrow disorders: quantitative chemical shift MR imaging.
Rosen, B. R., Fleming, D. M., Kushner, D. C., Zaner, K. S., Buxton, R. B., Bennet, W. P., Wismer, G. L., & Brady, T. J. (1988) · Radiology · doi:10.1148/radiology.169.3.3187003 · Cited by 107
Chemical shift-induced amplitude modulations in images obtained with gradient refocusing
Wehrli, F. W., Perkins, T. G., Shimakawa, A. S., & Roberts, F. E. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90045-2 · Cited by 93
Schwartz, L. H., Panicek, D. M., Koutcher, J. A., Brown, K. T., Getrajdman, G. I., Heelan, R. T., & Burt, M. (1995) · Radiology · doi:10.1148/radiology.197.2.7480686 · Cited by 69
Localized in vivo proton spectroscopy of the bone marrow in patients with leukemia
Jensen, K. E., Jensen, M., Grundtvig, P., Thomsen, C. E., Karle, H., & Henriksen, O. B. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90014-s · Cited by 67
Cited by
Fat Suppression in MR Imaging: Techniques and Pitfalls
Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999) · RadioGraphics · doi:10.1148/radiographics.19.2.g99mr03373 · Cited by 487
Musculoskeletal Tumors: How to Use Anatomic, Functional, and Metabolic MR Techniques
Fayad, L. M., Jacobs, M. A., Wang, X., Carrino, J. A., & Bluemke, D. A. (2012) · Radiology · doi:10.1148/radiol.12111740 · Cited by 219
The role of magnetic resonance imaging in the evaluation of bone tumours and tumour-like lesions
Nascimento, D., Suchard, G., Hatem, M., & de Abreu, A. (2014) · Insights into Imaging · doi:10.1007/s13244-014-0339-z · Cited by 106
Metadata
- Authors
- Disler, D. G., McCauley, T. R., Ratner, L. M., Kesack, C. D., & Cooper, J. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1997-11
- Volume
- 169
- Issue
- 5
- Pages
- 1439-1447
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1988290246
- Cited by
- 187
- References
- 14
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.