CoChat

MRI Features Predictive of Invasive Placenta With Extrauterine Spread in High-Risk Gravid Patients: A Prospective Evaluation

Bourgioti, Charis, Zafeiropoulou, Konstantina, Fotopoulos, Stavros, Nikolaidou, Maria Evangelia, Antoniou, Aristeidis, Tzavara, Chara, Moulopoulos, Lia Angela · 2018 · American Journal of Roentgenology
Cited by 57

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of our study was to evaluate MRI diagnostic ability in predicting invasive placenta with extrauterine spread in high-risk gravid patients. SUBJECTS AND METHODS: Between March 2016 and June 2017, 49 patients (mean age, 35.7 years; mean gestational age, 32.5 weeks) with sonographically confirmed placenta previa underwent dedicated MRI. All MRI examinations were reviewed by two experienced radiologists prospectively. Intraoperative and pathologic findings were the standard of reference. Kappa values were calculated to assess the agreement between MRI findings and histologic results as well as interrater reliability. ROC curve analysis was used to test the discriminative ability of MRI features for invasive placenta with extrauterine spread. Stepwise multiple logistic regression analysis was performed to identify any MRI findings predictive of invasive placenta and of bladder and parametrial involvement. RESULTS: MRI exhibited significant overall accuracy (AUC = 0.77, p = 0.006) in identifying invasive placenta with 100% sensitivity and negative predictive values; it was highly specific (100%) in identifying placental extension to both bladder and parametrial tissues. Lumpy tapering of the placental edges, intraplacental dark T2 bands, prominent intraplacental vascularity, and serosal hypervascularity were independently associated with an increased risk for invasive placenta. Serosal hypervascularity and vesicouterine space hypervascularity were independent predictors of bladder invasion; abnormal vascularization within the parametrial fat was significant for parametrial invasion. CONCLUSION: MRI is highly accurate in depicting placental extrauterine spread. The presence of abnormal vessels at the uterine serosa was the most important MRI feature for identifying invasive placenta. An abnormal vascular network within the vesicouterine space or parametrium was the most reliable MRI sign for detecting bladder or parametrial involvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.17.19303

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Bourgioti, C., Zafeiropoulou, K., Fotopoulos, S., Nikolaidou, M. E., Antoniou, A., Tzavara, C., & Moulopoulos, L. A.
Venue
American Journal of Roentgenology
Published
2018-09
Volume
211
Issue
3
Pages
701-711
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2847887408
Cited by
57
References
10
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.