Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record.

Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters.

Krejza, J, Mariak, Z, Walecki, J, Szydlik, P, Lewko, J, Ustymowicz, A · 1999 · American Journal of Roentgenology

Abstract

OBJECTIVE: Only a limited number of transcranial color-coded Doppler studies have provided ranges for the normal reference values of cerebral hemodynamic parameters. These reports are not fully convergent in relation to the range of values or to the age and sex dependence of blood flow parameters. The aim of the present study was to provide data regarding normal reference ranges. SUBJECTS AND METHODS: We examined 182 healthy volunteers (79 men and 103 women; age range, 20-86 years old) with color-coded Doppler sonography via a temporal acoustic window with a 2.5-MHz transcranial probe. The subjects were divided into three age groups: 20-40 years old (group 1), 41-60 years old (group 2), and more than 60 years old (group 3). Angle-corrected peak systolic, end-diastolic, and mean velocities as well as impedance indexes were determined in anterior, middle, and posterior cerebral arteries. RESULTS: Mean velocity values for middle, anterior, and posterior cerebral arteries in age group 1 were 81+/-20, 56+/-14, and 52+/-12 cm/sec (mean +/- SD), respectively. In group 2, the values were 73+/-19, 53+/-16, and 51+/-12 cm/sec (mean +/- SD), and in group 3, the values were 59+/-11, 44+/-11, and 40+/-9 cm/sec (mean +/- SD). Decrease in blood flow velocities and a concomitant increase in impedance indexes were found in all vessels with advancing age-findings that were most pronounced in subjects who were more than 40 years old. In the 20- to 40-year-old group, mean velocities for all vessels were higher in women than in men, whereas impedance indexes were not significantly different. CONCLUSION: Flow velocities in basal cerebral arteries range widely and are significantly age dependent. Age and sex matching of Doppler sonographic data is a prerequisite for clinically valuable conclusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.172.1.9888770

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Krejza, J., Mariak, Z., Walecki, J., Szydlik, P., Lewko, J., & Ustymowicz, A.
Venue
American Journal of Roentgenology
Published
1999-01
Volume
172
Issue
1
Pages
213-218
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2041441424
Cited by
184
References
0
FWCI
5.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters. https://app.cochat.ai/papers/10.2214/ajr.172.1.9888770
The paper
Krejza, J., Mariak, Z., Walecki, J., Szydlik, P., Lewko, J., & Ustymowicz, A. (1999). Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters. American Journal of Roentgenology. https://doi.org/10.2214/ajr.172.1.9888770

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.