Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters.
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Only a limited number of transcranial color-coded Doppler studies have provided ranges for the normal reference values of cerebral hemodynamic parameters. These reports are not fully convergent in relation to the range of values or to the age and sex dependence of blood flow parameters. The aim of the present study was to provide data regarding normal reference ranges. SUBJECTS AND METHODS: We examined 182 healthy volunteers (79 men and 103 women; age range, 20-86 years old) with color-coded Doppler sonography via a temporal acoustic window with a 2.5-MHz transcranial probe. The subjects were divided into three age groups: 20-40 years old (group 1), 41-60 years old (group 2), and more than 60 years old (group 3). Angle-corrected peak systolic, end-diastolic, and mean velocities as well as impedance indexes were determined in anterior, middle, and posterior cerebral arteries. RESULTS: Mean velocity values for middle, anterior, and posterior cerebral arteries in age group 1 were 81+/-20, 56+/-14, and 52+/-12 cm/sec (mean +/- SD), respectively. In group 2, the values were 73+/-19, 53+/-16, and 51+/-12 cm/sec (mean +/- SD), and in group 3, the values were 59+/-11, 44+/-11, and 40+/-9 cm/sec (mean +/- SD). Decrease in blood flow velocities and a concomitant increase in impedance indexes were found in all vessels with advancing age-findings that were most pronounced in subjects who were more than 40 years old. In the 20- to 40-year-old group, mean velocities for all vessels were higher in women than in men, whereas impedance indexes were not significantly different. CONCLUSION: Flow velocities in basal cerebral arteries range widely and are significantly age dependent. Age and sex matching of Doppler sonographic data is a prerequisite for clinically valuable conclusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Evaluation of cerebrovascular spasm with transcranial Doppler ultrasound
Aaslid, R., Huber, P., & Nornes, H. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.60.1.0037 · Cited by 681
Human cerebral blood flow and oxygen consumption as related to aging
Kety, S. S. (1956) · Journal of Chronic Diseases · doi:10.1016/0021-9681(56)90146-1 · Cited by 331
Cerebral blood flow changes in benign aging and cerebrovascular disease
Shaw, T. G., Mortel, K. F., Meyer, J. S., Rogers, R. L., Hardenberg, J., & Cutaia, M. M. (1984) · Neurology · doi:10.1212/wnl.34.7.855 · Cited by 315
Sex Differences in Regional Cerebral Blood Flow
Rodriguez, G., Warkentin, S., Risberg, J., & Rosadini, G. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.133 · Cited by 267
Transcranial doppler sonography: Anatomical landmarks and normal velocity values
Ringelstein, E. B., Kahlscheuer, B., Niggemeyer, E., & Otis, S. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90039-f · Cited by 263
Kirkham, F. J., Padayachee, T. S., Parsons, S., Seargeant, L. S., House, F. R., & Gosling, R. G. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90139-0 · Cited by 237
Transcranial Doppler Examination Techniques
Aaslid, R. (1986) · Transcranial Doppler Sonography · doi:10.1007/978-3-7091-8864-4_4 · Cited by 228
Normal Size of the Internal Carotid, Middle Cerebral and Anterior Cerebral Arteries
Gabrielsen, T. O., & Greitz, T. V. B. (1970) · Acta Radiologica Diagnosis · doi:10.1177/028418517001000101 · Cited by 145
Grolimund, P., & Seiler, R. W. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90139-1 · Cited by 139
Cited by
Cerebral microvascular pathology in aging and Alzheimer's disease
Farkas, E., & Luiten, P. G. M. (2001) · Progress in Neurobiology · doi:10.1016/s0301-0082(00)00068-x · Cited by 1,102
“In human aging studies, the cerebral perfusion of healthy volunteers was examined in different age groups ranging from 14 to 100 years old (Tachibana et al., 1984; Iwata and Harano, 1986; Reich and Rusinek, 1989; Vriens et al., 1989; Ackerstaff et al., 1990; Kawamura et al., 1993; Krejza et al., 1999; Schultz et al.,…”
BackgroundMethodInfluentialAlterations in the BOLD fMRI signal with ageing and disease: a challenge for neuroimaging
D'Esposito, M., Deouell, L. Y., & Gazzaley, A. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1246 · Cited by 866
Sloan, M. A., Alexandrov, A. V., Tegeler, C. H., Spencer, M. P., Caplan, L. R., Feldmann, E., Wechsler, L. R., Newell, D. W., Gomez, C. R., Babikian, V. L., et al. (2004) · Neurology · doi:10.1212/wnl.62.9.1468 · Cited by 517
Age-related Impairment of Vascular Structure and Functions
Xu, X., Wang, B., Ren, C., Hu, J., Greenberg, D. A., Chen, T., Xie, L., & Jin, K. (2017) · Aging and disease · doi:10.14336/ad.2017.0430 · Cited by 330
Microvascular plasticity in aging
Riddle, D. R., Sonntag, W. E., & Lichtenwalner, R. J. (2003) · Ageing Research Reviews · doi:10.1016/s1568-1637(02)00064-8 · Cited by 223
Murrell, C. J., Cotter, J. D., Thomas, K. N., Lucas, S. J. E., Williams, M. J. A., & Ainslie, P. N. (2013) · AGE · doi:10.1007/s11357-012-9414-x · Cited by 207
Scheel, P., Ruge, C., & Schöning, M. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00293-3 · Cited by 206
Valen-Sendstad, K., & Steinman, D. A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3793 · Cited by 177
“A fully developed Womersley velocity profile was applied at the inlet on the basis of a representative older adult ICA flow waveform23 damped by 30% to account for the reduced pulsatility at the MCA.24 A cycle-averaged cross-sec- AJNR Am J Neuroradiol 35:536 – 43 Mar 2014 www.ajnr.org 537 tional mean velocity of 0.37…”
MethodInfluentialTarantini, S., Tucsek, Z., Valcarcel-Ares, M. N., Toth, P., Gautam, T., Giles, C. B., Ballabh, P., Wei, J. Y., Wren, J. D., Ashpole, N. M., et al. (2016) · AGE · doi:10.1007/s11357-016-9931-0 · Cited by 98
The pericyte–glia interface at the blood–brain barrier
Giannoni, P., Badaut, J., Dargazanli, C., De Maudave, A. F., Klement, W., Costalat, V., & Marchi, N. (2018) · Clinical Science · doi:10.1042/cs20171634 · Cited by 81
Metadata
- Authors
- Krejza, J., Mariak, Z., Walecki, J., Szydlik, P., Lewko, J., & Ustymowicz, A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1999-01
- Volume
- 172
- Issue
- 1
- Pages
- 213-218
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2041441424
- Cited by
- 184
- References
- 13
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.