Sample Size Tables For Receiver Operating Characteristic Studies
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: I provide researchers with tables of sample size for multiobserver receiver operating characteristic (ROC) studies that compare the diagnostic accuracies of two imaging techniques. MATERIALS AND METHODS: I computed the number of patients and observers needed as a function of five parameters: the measure of diagnostic accuracy (area under the ROC curve, sensitivity at a false-positive rate </= 0.10, or specificity at a false-negative rate </= 0.10), conjectured level of accuracy, suspected difference in accuracy between the two imaging techniques, observer variability, and ratio of patients without to patients with the condition. RESULTS: The numbers of patients and observers required vary dramatically with these five parameters, increasing with more refined measures of accuracy, with lower accuracy levels, with smaller suspected differences, with greater observer variability, and with less balanced designs. The number of patients required for a study can be reduced by increasing the number of observers, and vice versa. When the intra- and interobserver variability is large, a study design with just four observers is usually inadequate. CONCLUSION: Many factors must be considered when determining the appropriate sample sizes for multiobserver ROC studies. My tables serve only as initial ballpark estimates. Investigators should compute sample size using parameters that reflect their clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 1×
“It is a good global measure of accuracy [2]; however, for particular clinical applications, we are usually interested in only a certain portion of the ROC curve [3].”
BackgroundProblems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Dorfman, D. D., Berbaum, K. S., & Metz, C. E. (1992) · PubMed · Cited by 724
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Analyzing a Portion of the ROC Curve
McClish, D. K. (1989) · Medical Decision Making · doi:10.1177/0272989x8900900307 · Cited by 707 · cited 1×
“It is a good global measure of accuracy [2]; however, for particular clinical applications, we are usually interested in only a certain portion of the ROC curve [3].”
BackgroundDORFMAN, D. D., BERBAUM, K. S., & METZ, C. E. (1992) · Investigative Radiology · doi:10.1097/00004424-199209000-00015 · Cited by 661 · cited 1×
“Other more sophisticated models exist [6, 7], but no associated algorithms are available for calculating sample size.”
BackgroundSAMPLE SIZE DETERMINATION FOR DIAGNOSTIC ACCURACY STUDIES INVOLVING BINORMAL ROC CURVE INDICES
OBUCHOWSKI, N. A., & McCLISH, D. K. (1997) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19970715)16:13<1529::aid-sim565>3.0.co;2-h · Cited by 332
Self-citationObuchowski, N. A., & Rockette, H. E. (1995) · Communications in Statistics - Simulation and Computation · doi:10.1080/03610919508813243 · Cited by 234
Self-citationAssessment of radiologic tests: control of bias and other design considerations.
Begg, C. B., & McNeil, B. J. (1988) · Radiology · doi:10.1148/radiology.167.2.3357976 · Cited by 213
Cited by
Sample size estimation in diagnostic test studies of biomedical informatics
Hajian-Tilaki, K. (2014) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2014.02.013 · Cited by 995
ROC Curves in Clinical Chemistry: Uses, Misuses, and Possible Solutions
Obuchowski, N. A., Lieber, M. L., & Wians, F. H. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031823 · Cited by 358
“For further discussion of sample size issues, see Zhou et al. (2) or Obuchowski (38) .”
BackgroundSelf-citationObuchowski (2005) · doi:10.2214/ajr.184.2.01840364 · Cited by 321
Conant, E. F., Toledano, A. Y., Periaswamy, S., Fotin, S. V., Go, J., Boatsman, J. E., & Hoffmeister, J. W. (2019) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2019180096 · Cited by 241
“Sample size was calculated (21,22) from a previous pilot reader study with the DBT AI system.”
MethodDevelopment and Initial Validation of a Self-Scored COPD Population Screener Questionnaire (COPD-PS)
Martinez, F. J., Raczek, A. E., Seifer, F. D., Conoscenti, C. S., Curtice, T. G., D'Eletto, T., Cote, C., Hawkins, C., & Phillips, A. L. (2008) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550801940721 · Cited by 236
Lazzeri, M., Haese, A., de la Taille, A., Palou Redorta, J., McNicholas, T., Lughezzani, G., Scattoni, V., Bini, V., Freschi, M., Sussman, A., et al. (2013) · European Urology · doi:10.1016/j.eururo.2013.01.011 · Cited by 215
Digital Breast Tomosynthesis Is Comparable to Mammographic Spot Views for Mass Characterization
Noroozian, M., Hadjiiski, L., Rahnama-Moghadam, S., Klein, K. A., Jeffries, D. O., Pinsky, R. W., Chan, H.-P., Carson, P. L., Helvie, M. A., & Roubidoux, M. A. (2012) · Radiology · doi:10.1148/radiol.11101763 · Cited by 160
Artificial Intelligence in Medicine: Validation and Study Design
Oakden-Rayner, L., & Palmer, L. J. (2019) · Artificial Intelligence in Medical Imaging · doi:10.1007/978-3-319-94878-2_8 · Cited by 14
Metadata
- Authors
- Obuchowski, N. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-09
- Volume
- 175
- Issue
- 3
- Pages
- 603-608
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1974263416
- Cited by
- 159
- References
- 13
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.