Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Abstract
OBJECTIVE: In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS: Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS: The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a 1-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States, of approximately 600,000 abdominal and head CT examinations annually performed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION: The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing, estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Brenner et al. concluded already in 2001 that paediatric CT scans significantly increase the lifetime risk of cancer mortality due to the higher radiation sensitivity of children”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [66]
Citations
Cites
Sources and effects of ionizing radiation
United Nations Scientific Committee on the Effects of Atomic Radiation (2018) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/f48d655d-en · Cited by 3,981
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,148
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 1×
“The risk estimates given here are for lifetime cancer mortality; estimated cancer risks from pediatric CT examinations would, by definition, be larger, particularly for CT examinations of the head, because of the larger contribution of radiation-induced thyroid cancer [34].”
BackgroundStudies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Væth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 938
Risk of childhood cancer from fetal irradiation.
Doll, R., & Wakeford, R. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135438 · Cited by 683
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationHealth effects of exposure to low levels of ionizing radiation
Schonken, P. (1991) · Health Policy · doi:10.1016/0168-8510(91)90028-v · Cited by 530
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
UNSCEAR 2000. The United Nations Scientific Committee on the Effects of Atomic Radiation
(2000) · PubMed · Cited by 314
Radiation Exposures to Patients from CT
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 221
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 214
Severe viral respiratory infections in infants with cystic fibrosis
Armstrong, D., Grimwood, K., Carlin, J. B., Carzino, R., Hull, J., Olinsky, A., & Phelan, P. D. (1998) · Pediatric Pulmonology · doi:10.1002/(sici)1099-0496(199812)26:6 · Cited by 196
Influence of patient age on normalized effective doses calculated for CT examinations
Khursheed, A., Hillier, M. C., Shrimpton, P. C., & Wall, B. F. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.898.750819 · Cited by 191
Shrimpton, P. C., & Edyvean, S. (1998) · British Journal of Radiology · doi:10.1259/bjr.71.841.9534691 · Cited by 190
Karlsson, P., Holmberg, E. C., Lundell, M., Mattsson, A. F., Holm, L.-E., & Wallgren, A. (1998) · Radiation Research · doi:10.2307/3579984 · Cited by 190
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Computer-Simulated Radiation Dose Reduction for Abdominal Multidetector CT of Pediatric Patients
Frush, D. P., Slack, C. C., Hollingsworth, C. L., Bisset, G. S., Donnelly, L. F., Hsieh, J., Lavin-Wensell, T., & Mayo, J. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791107 · Cited by 174
Perfect is the enemy of the very good
Slovis, T. L., & Berdon, W. E. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0669-8 · Cited by 174
Self-citationCT scanning: A major source of radiation exposure
Wiest, P. W., Locken, J. A., Heintz, P. H., & Mettler, F. A. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90011-9 · Cited by 173
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
Effective doses to patients undergoing thoracic computed tomography examinations
Huda, W., Scalzetti, E. M., & Roskopf, M. L. (2000) · Medical Physics · doi:10.1118/1.598949 · Cited by 144
Haaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Mahesh, M., Scatarige, J. C., Cooper, J., & Fishman, E. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771273 · Cited by 138
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · Medical Physics · doi:10.1118/1.1415074 · Cited by 134
Self-citationStandard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality
Prasad, S. R., Wittram, C., Shepard, J.-A. O., McLoud, T. C., & Rhea, J. T. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790461 · Cited by 130
Infante‐Rivard, C., Mathonnet, G., & Sinnett, D. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108495 · Cited by 123
Peña, B. M. G., Taylor, G. A., Lund, D. P., & Mandl, K. D. (1999) · PEDIATRICS · doi:10.1542/peds.104.3.440 · Cited by 116
Caon, M., Bibbo, G., & Pattison, J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/9/309 · Cited by 112
Improved Pediatric Multidetector Body CT Using a Size-Based Color-Coded Format
Frush, D. P., Soden, B., Frush, K. S., & Lowry, C. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.3.1780721 · Cited by 107
Feigal, D. W. (2002) · International Journal of Trauma Nursing · doi:10.1067/mtn.2002.121511 · Cited by 87
Feasibility of high-resolution, low-dose chest CT in evaluating the pediatric chest
Ambrosino, M. M., Genieser, N. B., Roche, K. J., Kaul, A., & Lawrence, R. M. (1994) · Pediatric Radiology · doi:10.1007/bf02017649 · Cited by 82
Helical CT in children: technical considerations and body applications.
Frush, D. P., & Donnelly, L. F. (1998) · Radiology · doi:10.1148/radiology.209.1.9769810 · Cited by 82
Mower, W. R., Hoffman, J. R., Herbert, M., Wolfson, A. B., Pollack, C. V., & Zucker, M. I. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.129245 · Cited by 81
(1993) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/0300f937-en · Cited by 79
Helical body CT: evolution of scanning protocols.
Zeman, R. K., BARON, R. L., Jeffrey, R. B., Klein, J. S., Siegel, M. J., & Silverman, P. M. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.6.9609149 · Cited by 73
Slovis, T. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790039 · Cited by 71
Radiation dose reduction in CT of the pediatric pelvis.
Kamel, I. R., Hernandez, R. J., Martin, J. E., Schlesinger, A. E., Niklason, L. T., & Guire, K. E. (1994) · Radiology · doi:10.1148/radiology.190.3.8115611 · Cited by 68
No evidence for increased tumor rates below 200 mSv in the atomic bomb survivors data
Heidenreich, W., Paretzke, H. G., & Jacob, P. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050073 · Cited by 63
Invited article: Helical/spiral CT scanning: a pediatric radiology perspective
White, K. S. (1996) · Pediatric Radiology · doi:10.1007/bf01403695 · Cited by 62
Using CT of the Cervical Spine for Early Evaluation of Pediatric Patients with Head Trauma
Keenan, H. T., Hollingshead, M. C., Chung, C. J., & Ziglar, M. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771405 · Cited by 62
Survey of CT techniques and absorbed dose in various Dutch hospitals.
van Unnik, J. G., Broerse, J. J., Geleijns, J., Jansen, J. T. M., Zoetelief, J., & Zweers, D. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.832.9166072 · Cited by 59
Average radiation dose in standard CT examinations of the head: results of the 1990 NEXT survey.
Conway, B. J., McCrohan, J. L., Antonsen, R. G., Rueter, F. G., Slayton, R. J., & Suleiman, O. H. (1992) · Radiology · doi:10.1148/radiology.184.1.1609069 · Cited by 59
How do radiographic techniques affect image quality and patient doses in CT?
Huda, W., Ravenel, J. G., & Scalzetti, E. M. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90012-0 · Cited by 58
Orbital, thyroid, and breast superficial radiation shielding for patients undergoing diagnostic CT
Hopper, K. D. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90013-2 · Cited by 58
Frush, D. P. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0684-9 · Cited by 55
Rogers, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770277 · Cited by 54
Radiation Dose and Somatic Risk from Computed Tomography
Faulkner, K., & Moores, B. M. (1987) · Acta Radiologica · doi:10.1177/028418518702800422 · Cited by 49
Brant-Zawadzki, M. N. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790319 · Cited by 48
Radiation dose reduction in paediatric cranial CT
Chan, C. Y., Wong, Y. P., Chau, L., Yu, S., & Lau, P.-C. (1999) · Pediatric Radiology · doi:10.1007/s002470050692 · Cited by 44
Vade, A., Demos, T. C., Olson, M. C., Subbaiah, P., Turbin, R. C., Vickery, K., & Corrigan, K. (1996) · Pediatric Radiology · doi:10.1007/bf03178045 · Cited by 42
Radiation risks in perspective: radiation-induced cancer among cancer risks
Tubiana, M. (2000) · Radiation and Environmental Biophysics · doi:10.1007/pl00007682 · Cited by 41
Radiation dose reduction in pediatric CT
Robinson, A. E., Hill, E. P., & Harpen, M. D. (1986) · Pediatric Radiology · doi:10.1007/bf02387506 · Cited by 36
Dose Reduction in CT: How Low Can We Go?
Rogers, L. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790299 · Cited by 35
Analysis of Factors Influencing Patient Doses from CT in Norway
Olerud, H. M. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032039 · Cited by 34
National CT use and radiation exposure: United States 1983
Evens, R., & Mettler, F. A. (1985) · American Journal of Roentgenology · doi:10.2214/ajr.144.5.1077 · Cited by 31
Normalized pediatric organ-absorbed doses from CT examinations
Fearon, T. C., & Vucich, J. J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.1.171 · Cited by 30
In x‐ray computed tomography, technique factors should be selected appropriate to patient size
Huda, W., Bushong, S. C., & Hendee, W. R. (2001) · Medical Physics · doi:10.1118/1.1388903 · Cited by 30
Current issues in the diagnosis and management of pediatric empyema
Lewis, R. A., & Feigin, R. D. (2002) · Seminars in Pediatric Infectious Diseases · doi:10.1053/spid.2002.127197 · Cited by 29
Provision of MRI can significantly reduce CT collective dose
Clarke, J., Cranley, K., Kelly, B. E., Bell, K. W., & Smith, P. H. S. (2001) · British Journal of Radiology · doi:10.1259/bjr.74.886.740926 · Cited by 28
Low-Tube-Current Multidetector CT for Children with Suspected Extrinsic Airway Compression
Pacharn, P., Poe, S. A., & Donnelly, L. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.6.1791523 · Cited by 25
Radiation Dose and Somatic Risk from computed tomography
Faulkner, K., & Moores, B. M. (1987) · Acta Radiologica · doi:10.3109/02841858709177386 · Cited by 25
Solid cancer risks from radiation exposure for the Australian population
Wise, K. N. (2003) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/bf03178458 · Cited by 23
TRENDS IN PEDIATRIC EMERGENCY IMAGING
John, S. D. (1999) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(05)70141-x · Cited by 22
Is energy imparted a good measure of the radiation risk associated with CT examinations?
Huda, W. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/9/010 · Cited by 20
Radiofrequency Ablation of the Liver
de Baère, T. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.5.1771213 · Cited by 15
Strom, D. J., CAMERON, J. R., & Cohen, B. L. (1998) · Medical Physics · doi:10.1118/1.598207 · Cited by 12
Rosen, N. S. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.3.1770715b · Cited by 11
Radiation Risk From Diagnostic Imaging
Brody, A. S., & Guillerman, R. P. (2002) · Pediatric Annals · doi:10.3928/0090-4481-20021001-08 · Cited by 11
on: 'No evidence for increased tumor rates below 200 mSv in the atomic bomb survivors' data'.
Pierce, D. A., & Preston, D. L. (1997) · PubMed · Cited by 11
Science radiation protection and the NCRP
Sinclair, W. K. (1993) · National Council on Radiation Protection and Measurements eBooks · Cited by 10
Future Directions of Congenital Heart Disease Imaging
Geva, T. (2002) · Pediatric Cardiology · doi:10.1007/s00246-001-0062-7 · Cited by 10
Aspects of examination frequency and quality assurance
Shrimpton, P. C. (1991) · National Radiological Protection Board eBooks · Cited by 9
Introduction to Seminar in Radiation Dose Reduction
Slovis, T. L. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0795-3 · Cited by 8
Helical CT Angiography of Thoracic Outlet Syndrome
Matsumura, J. S., Yao, J. S. T., & Nemcek, A. A. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.3.1770714 · Cited by 7
Altes, T. A. (2002) · Pediatric Annals · doi:10.3928/0090-4481-20021001-11 · Cited by 6
Imaging of appendicitis: a cautionary note
Shorvon, P. J. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.897.750717 · Cited by 6
Nichols, A. V. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.5.1771218a · Cited by 3
Research works printed but not linked: 2
- Chamberlain C, Huda W, Rosenbaum A, Garissi W. Adult and pediatric radiation doses in head CT examinations. (abstr) Med Phys 1998; 25:A216
- National Council on Radiation Protection and Measurements. Evaluation of the linear non-threshold dose-response model. Bethesda, MD: NCRP Publications, 2000 (in press)
Cited by
Sorted by citations
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,738
Self-citationPearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Smith‐Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,467
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · CHEST Journal · doi:10.1378/chest.07-2800 · Cited by 2,058
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Metadata
- Authors
- Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 289-296
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2138025351
- Cited by
- 3,222
- References
- 79
- Citations by year
- 2026: 44 · 2025: 92 · 2024: 78 · 2023: 115 · 2022: 116 · 2021: 134 · 2020: 148 · 2019: 137 · 2018: 124 · 2017: 141 · 2016: 190 · 2015: 186 · 2014: 179 · 2013: 176 · 2012: 213
- FWCI
- 60.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca077285-03)
- National Cancer Institute (CA77285)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- pediatric computed tomography, radiation-induced cancer, age at diagnosis, linear no-threshold model, low-dose radiation risk, abdominal CT, head CT, benefits and risks
- MeSH terms
- Adolescent, Cause of Death, Child, Child, Preschool, Female, Humans, Infant, Infant, Newborn, Male, Neoplasms, Radiation-Induced, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review