The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Abstract
OBJECTIVE: In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS: Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS: The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a 1-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States, of approximately 600,000 abdominal and head CT examinations annually performed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION: The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing, estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Brenner et al. concluded already in 2001 that paediatric CT scans significantly increase the lifetime risk of cancer mortality due to the higher radiation sensitivity of children”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [66]
Citations
Cites
Sources and effects of ionizing radiation
United Nations Scientific Committee on the Effects of Atomic Radiation (2018) · Report of the United Nations Scientific Committee on the Effects of Atomic Radiation · doi:10.18356/f48d655d-en · Cited by 3,981
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,148
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (2012) · Radiation Research · doi:10.1667/rrav05.1 · Cited by 1,124
Thyroid Cancer after Exposure to External Radiation: A Pooled Analysis of Seven Studies
Ron, E., Lubin, J. H., Shore, R. E., Mabuchi, K., Modan, B., Pottern, L. M., Schneider, A. B., Tucker, M. A., & Boice, J. D. (1995) · Radiation Research · doi:10.2307/3579003 · Cited by 1,107 · cited 1×
“The risk estimates given here are for lifetime cancer mortality; estimated cancer risks from pediatric CT examinations would, by definition, be larger, particularly for CT examinations of the head, because of the larger contribution of radiation-induced thyroid cancer [34].”
BackgroundStudies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Væth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 938
Risk of childhood cancer from fetal irradiation.
Doll, R., & Wakeford, R. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.830.9135438 · Cited by 683
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationHealth effects of exposure to low levels of ionizing radiation
Schonken, P. (1991) · Health Policy · doi:10.1016/0168-8510(91)90028-v · Cited by 530
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Research works printed but not linked: 2
- Chamberlain C, Huda W, Rosenbaum A, Garissi W. Adult and pediatric radiation doses in head CT examinations. (abstr) Med Phys 1998; 25:A216
- National Council on Radiation Protection and Measurements. Evaluation of the linear non-threshold dose-response model. Bethesda, MD: NCRP Publications, 2000 (in press)
Cited by
Sorted by citations
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,738
Self-citationPearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Smith‐Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,467
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · CHEST Journal · doi:10.1378/chest.07-2800 · Cited by 2,058
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,007
Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
Wei, H., Fang, Y., Mulligan, P. L., Chuirazzi, W., Fang, H., Wang, C., Ecker, B., Gao, Y., Loi, M. A., Cao, L. R., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.41 · Cited by 1,889
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Miglioretti, D. L., Johnson, E., Williams, A. E., Greenlee, R. T., Weinmann, S. A., Solberg, L. I., Feigelson, H. S., Roblin, D. W., Flynn, M. J., Vanneman, N., et al. (2013) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A. O., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,083
Sodickson, A. D., Baeyens, P. F., Andriole, K. P., Prevedello, L. M. S., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 993
Management of Stroke in Infants and Children
Roach, E. S., Golomb, M. R., Adams, R. J., Biller, J., Daniels, S. R., deVeber, G., Ferriero, D. M., Jones, B. V., Kirkham, F. J., Scott, R. M., et al. (2008) · Stroke · doi:10.1161/strokeaha.108.189696 · Cited by 959
Cancer risks from diagnostic radiology
Hall, E. J., & Brenner, D. J. (2008) · British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 916
Self-citationStrategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch‐Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 822
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · Radiographics · doi:10.1148/rg.262055138 · Cited by 769
US or CT for Diagnosis of Appendicitis in Children and Adults? A Meta-Analysis
Doria, A. S., Moineddin, R., Kellenberger, C. J., Epelman, M. S., Beyene, J., Schuh, S., Babyn, P., & Dick, P. T. (2006) · Radiology · doi:10.1148/radiol.2411050913 · Cited by 742
Lung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 763
Lee, C. I., Haims, A. H., Monico, E., Brink, J. A., & Forman, H. P. (2004) · Radiology · doi:10.1148/radiol.2312030767 · Cited by 700
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Lei Zhang, A., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Estimated Radiation Risks Potentially Associated with Full-Body CT Screening
Brenner, D. J., & Elliston, C. D. (2004) · Radiology · doi:10.1148/radiol.2323031095 · Cited by 684
Self-citationZhuang, R., Wang, X., Ma, W., Wu, Y., Chen, X., Tang, L., Zhu, H., Liu, J., Wu, L., Zhou, W., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0466-7 · Cited by 633
Ultrasound diagnosis of occult pneumothorax*
Lichtenstein, D. A., Mezière, G. A., Lascols, N., Biderman, P., Courret, J.-P., Gepner, A., Goldstein, I., & Tenoudji-Cohen, M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000164542.86954.b4 · Cited by 629
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · PEDIATRICS · doi:10.1542/peds.112.4.951 · Cited by 617
AAPM/RSNA Physics Tutorial for Residents: Topics in CT
McNitt‐Gray, M. F. (2002) · Radiographics · doi:10.1148/rg.226025128 · Cited by 612
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch‐Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 591
The Measurement, Reporting, and Management of Radiation Dose in CT
McCollough, C. H., CODY, D. D., Edyvean, S., Geise, R. A., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W. A., McNitt‐Gray, M., et al. (2008) · doi:10.37206/97 · Cited by 570
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 555
Self-citationYou, C., Cong, W., Vannier, M. W., Saha, P. K., Hoffman, E. A., Wang, G., Li, G., Zhang, Y., Zhang, X., Shan, H., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2922960 · Cited by 542
Osmond, M. H., Klassen, T. P., Wells, G. A., Correll, R., Jarvis, A., Joubert, G. I., Bailey, B., Chauvin‐Kimoff, L., Pusic, M. V., McConnell, D., et al. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.091421 · Cited by 527
Hereditary haemorrhagic telangiectasia: a clinical and scientific review
Govani, F. S., & Shovlin, C. L. (2009) · European Journal of Human Genetics · doi:10.1038/ejhg.2009.35 · Cited by 481
Ludlow, J. B., Timothy, R. S., Walker, C., Hunter, R., Benavides, E., Samuelson, D. B., & Scheske, M. J. (2014) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140197 · Cited by 484
Increasing utilization of computed tomography in the adult emergency department, 2000–2005
Broder, J. S., & Warshauer, D. M. (2006) · Emergency Radiology · doi:10.1007/s10140-006-0493-9 · Cited by 477
Diagnosis and management of acute appendicitis. EAES consensus development conference 2015
Gorter, R. R., Eker, H. H., Gorter-Stam, M., Abis, G. S. A., Acharya, A., Ankersmit, M., Antoniou, S. A., Arolfo, S., Babic, B., Boni, L., et al. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-5245-7 · Cited by 506
Kurland, G., Deterding, R. R., Hagood, J. S., Young, L. R., Brody, A. S., Castile, R. G., Dell, S., Fan, L. L., Hamvas, A., Hilman, B. C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201305-0923st · Cited by 466
Noninvasive Coronary Artery Imaging
Bluemke, D. A., Achenbach, S. S., Budoff, M. J., Gerber, T. C., Gersh, B. J., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 455
Clinical Practice Guideline: Hoarseness (Dysphonia)
Schwartz, S. R., Cohen, S. M., Dailey, S. H., Rosenfeld, R. M., Deutsch, E. S., Gillespie, M. B., Granieri, E. C., Hapner, E. R., Kimball, C., Krouse, H. J., et al. (2009) · Otolaryngology · doi:10.1016/j.otohns.2009.06.744 · Cited by 453
National Trends in CT Use in the Emergency Department: 1995–2007
Larson, D. B., Johnson, L. W., Schnell, B. M., Salisbury, S. R., & Forman, H. P. (2010) · Radiology · doi:10.1148/radiol.10100640 · Cited by 443
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
Biswas, D., Bible, J. E., Bohan, M., Simpson, A. K., Whang, P. G., & Grauer, J. N. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.h.01199 · Cited by 441
Diagnostic Imaging of Child Abuse
Radiology, S. O. (2009) · PEDIATRICS · doi:10.1542/peds.2009-0558 · Cited by 437
Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., et al. (2005) · Radiology · doi:10.1148/radiol.2373041655 · Cited by 418
National Trends in Use of Computed Tomography in the Emergency Department
Kocher, K. E., Meurer, W. J., Fazel, R., Scott, P., Krumholz, H. M., & Nallamothu, B. K. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.05.020 · Cited by 401
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 399
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramírez-Giraldo, J. C., Qu, M., Christner, J. A., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 396
Vos, P. E., Alekseenko, Y. V., Battistin, L., Ehler, E., Gerstenbrand, F., Muresanu, D. F., Aa, P., Stepan, C. A., Traubner, P., Vécsei, L., et al. (2012) · European Journal of Neurology · doi:10.1111/j.1468-1331.2011.03581.x · Cited by 386
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
The “lung pulse”: an early ultrasound sign of complete atelectasis
Lichtenstein, D. A., Lascols, N., Prin, S., & Mezière, G. A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1930-9 · Cited by 369
Multiple-breath inert gas washout and spirometry versus structural lung disease in cystic fibrosis
Gustafsson, P. M., De Jong, P. A., Tiddens, H. A. W. M., & Lindblad, A. (2007) · Thorax · doi:10.1136/thx.2007.077784 · Cited by 364
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Mayo, J. R., Aldrich, J. E., & Müller, N. L. (2003) · Radiology · doi:10.1148/radiol.2281020874 · Cited by 359
Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Dijck, X. V., Mussen, E., Venstermans, C., & Termote, J. L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
(2013) · Oral surgery, oral medicine, oral pathology and oral radiology · doi:10.1016/j.oooo.2013.06.002 · Cited by 276
Hall, P. N., Adami, H., Trichopoulos, D., Pedersen, N. L., Lagiou, P., Ekbom, A., Ingvar, M., Lundell, M., & Granath, F. (2004) · BMJ · doi:10.1136/bmj.328.7430.19 · Cited by 350
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & Man, B. D. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 342
Managing Radiation Use in Medical Imaging: A Multifaceted Challenge
Hricak, H., Brenner, D. J., Adelstein, S. J., Frush, D. P., Hall, E. J., Howell, R. W., McCollough, C. H., Mettler, F. A., Pearce, M. S., Suleiman, O. H., et al. (2010) · Radiology · doi:10.1148/radiol.10101157 · Cited by 343
Self-citationComputed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, ., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 337
de Jong, P. A., Nakano, Y., Lequin, M. H., Mayo, J. R., Woods, R. R., Paré, P. D., & Tiddens, H. A. W. M. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00006603 · Cited by 318
Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice
Lee, C. H., Goo, J. M., Ye, H. J., Ye, S., Park, C. M., Chun, E. J., & Im, J.-G. (2008) · Radiographics · doi:10.1148/rg.285075075 · Cited by 315
CANCER RISKS FROM MEDICAL RADIATION
Ron, E. (2003) · Health Physics · doi:10.1097/00004032-200307000-00011 · Cited by 382
120 Crohn's Disease: Factors Associated with Exposure to High Levels of Diagnostic Radiation
Desmond, A. N., O'Regan, K. N., Curran, C., McWilliams, S., Maher, M. M., & Shanahan, F. (2008) · Gastroenterology · doi:10.1016/s0016-5085(08)60102-x · Cited by 307
Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor
Li, H., Song, J., Pan, W., Xu, D., Zhu, W., Wei, H., & Yang, B. (2020) · Advanced Materials · doi:10.1002/adma.202003790 · Cited by 307
Ultrasound in the management of thoracic disease
Lichtenstein, D. A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260674.60761.85 · Cited by 305
Nanoparticles for multimodal in vivo imaging in nanomedicine
Leary, J. F., & Key, J. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s53717 · Cited by 307
Tumors of the Nervous System and Pituitary Gland Associated With Atomic Bomb Radiation Exposure
Preston, D. L. (2002) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/94.20.1555 · Cited by 293
GROWTH OF THE THORACIC SPINE IN CONGENITAL SCOLIOSIS AFTER EXPANSION THORACOPLASTY
CAMPBELL, R. M., & Hell, A. K. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200303000-00002 · Cited by 291
Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations
Kutanzi, K. R., Lumen, A., Koturbash, I., & Miousse, I. R. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13111057 · Cited by 287
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 305
Thoeni, R. F., & Cello, J. P. (2006) · Radiology · doi:10.1148/radiol.2403050818 · Cited by 273
Cancer Incidence Rates and Trends Among Children and Adolescents in the United States, 2001–2009
Siegel, D. A., King, J., Tai, E. W., Buchanan, N., Ajani, U. A., & Li, J. (2014) · PEDIATRICS · doi:10.1542/peds.2013-3926 · Cited by 271
Kau, C. H., Richmond, S., Palomo, J. M., & Hans, M. G. (2005) · Journal of Orthodontics · doi:10.1179/146531205225021285 · Cited by 268
Rising Use of CT in Child Visits to the Emergency Department in the United States, 1995–2008
Larson, D. B., Johnson, L. W., Schnell, B. M., Goske, M. J., Salisbury, S. R., & Forman, H. P. (2011) · Radiology · doi:10.1148/radiol.11101939 · Cited by 267
Structural Growth Trajectories and Rates of Change in the First 3 Months of Infant Brain Development
Holland, D., Chang, L., Ernst, T. M., Curran, M., Buchthal, S. D., Alicata, D., Skranes, J., Johansen, H., Hernandez, A., Yamakawa, R., et al. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2014.1638 · Cited by 242
Griffey, R. T., & Sodickson, A. D. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1351 · Cited by 258
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton‐Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B. R., Lamm, D. L., O’Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 255
Patient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. Z. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
Exposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B. P., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
Abramson, D. H., & Schefler, A. C. (2004) · Retina · doi:10.1097/00006982-200412000-00002 · Cited by 246
A decision rule for identifying children at low risk for brain injuries after blunt head trauma
Palchak, M. J., Holmes, J. F., Vance, C., Gelber, R. E., Schauer, B. A., Harrison, M. J., Willis-Shore, J., Wootton‐Gorges, S. L., Derlet, R. W., & Kuppermann, N. (2003) · Annals of Emergency Medicine · doi:10.1067/s0196-0644(03)00425-6 · Cited by 247
Semelka, R. C., Armao, D. M., Elías, J., & Huda, W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20895 · Cited by 239
Dose in x-ray computed tomography
Kalender, W. A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/r129 · Cited by 237
Increasing utilization of computed tomography in the pediatric emergency department, 2000–2006
Broder, J. S., Fordham, L. A., & Warshauer, D. M. (2007) · Emergency Radiology · doi:10.1007/s10140-007-0618-9 · Cited by 234
Stovall, M., Weathers, R. E., Kasper, C. E., Smith, S. A., Travis, L. B., Ron, E., & Kleinerman, R. A. (2006) · Radiation Research · doi:10.1667/rr3525.1 · Cited by 234
Guidelines for imaging retinoblastoma: imaging principles and MRI standardization
de Graaf, P., Göricke, S. L., Rodjan, F., Galluzzi, P., Maeder, P. P., Castelijns, J. A., & Brisse, H. J. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2201-5 · Cited by 230
Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
Yu, L., Li, H., Fletcher, J. G., & McCollough, C. H. (2009) · Medical Physics · doi:10.1118/1.3264614 · Cited by 230
Funama, Y., Awai, K., Nakayama, Y., Kakei, K., Nagasue, N., Shimamura, M., Sato, N., Sultana, S., Morishita, S., & Yamashita, Y. (2005) · Radiology · doi:10.1148/radiol.2373041643 · Cited by 226
Cumulative Radiation Exposure and Cancer Risk Estimation in Children With Heart Disease
Johnson, J. N., Hornik, C. P. V., Li, J. S., Benjamin, D. K., Yoshizumi, T. T., Reiman, R. E., Frush, D. P., & Hill, K. D. (2014) · Circulation · doi:10.1161/circulationaha.113.005425 · Cited by 226
Mass Screening With CT Colonography: Should the Radiation Exposure Be of Concern?
Brenner, D. J., & Georgsson, M. A. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.05.021 · Cited by 224
Self-citationRadiation Exposures to Patients from CT
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 221
Chawla, S. C., Federman, N. C., Zhang, D., Nagata, K., Nuthakki, S., McNitt‐Gray, M. F., & Boechat, M. I. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1434-z · Cited by 218
Shah, N. B., & Platt, S. L. (2008) · Current Opinion in Pediatrics · doi:10.1097/mop.0b013e3282ffafd2 · Cited by 218
Yu, L., Bruesewitz, M. R., Thomas, K. B., Fletcher, J. G., Kofler, J. M., & McCollough, C. H. (2011) · Radiographics · doi:10.1148/rg.313105079 · Cited by 217
Huang, W.-Y., Muo, C.-H., Lin, C.-Y., Jen, Y.-M., Yang, M.-H., Lin, J.-C., Sung, F.-C., & Kao, C.-H. (2014) · British Journal of Cancer · doi:10.1038/bjc.2014.103 · Cited by 213
Retinoblastoma: Review of Current Management
Chintagumpala, M., Chévez‐Barrios, P., Paysse, E. A., Plon, S. E., & Hurwitz, R. L. (2007) · The Oncologist · doi:10.1634/theoncologist.12-10-1237 · Cited by 210
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Point-of-Care Ultrasonography by Pediatric Emergency Medicine Physicians
Marín, J. R., Lewiss, R. E., WORLD INTERACTIVE NETWORK FOCUSED ON CRITICAL ULTRASOUND, Shook, J. E., Ackerman, A. D., Chun, T. H., Conners, G. P., Dudley, N. C., Fuchs, S. M., Gorelick, M. H., et al. (2015) · PEDIATRICS · doi:10.1542/peds.2015-0343 · Cited by 209
Developing a Decision Instrument to Guide Computed Tomographic Imaging of Blunt Head Injury Patients
Mower, W. R., Hoffman, J. R., Herbert, M., Wolfson, A. B., Pollack, C. V., & Zucker, M. I. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000187813.79047.42 · Cited by 209
Role of Contrast-Enhanced Ultrasound (CEUS) in Paediatric Practice: An EFSUMB Position Statement
Sidhu, P. S., Cantisani, V., Deganello, A., Dietrich, C. F., Durán, C., Franke, D., Harkanyi, Z., Kosiak, W., Miele, V., Ntoulia, A., et al. (2016) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-110394 · Cited by 206
Jones, B. P., Tay, E. T., Elikashvili, I., Sanders, J. E., Paul, A. Z., Nelson, B. P., Spina, L. A., & Tsung, J. W. (2016) · CHEST Journal · doi:10.1016/j.chest.2016.02.643 · Cited by 205
Metadata
- Authors
- Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 289-296
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2138025351
- Cited by
- 3,222
- References
- 79
- Citations by year
- 2026: 44 · 2025: 92 · 2024: 78 · 2023: 115 · 2022: 116 · 2021: 134 · 2020: 148 · 2019: 137 · 2018: 124 · 2017: 141 · 2016: 190 · 2015: 186 · 2014: 179 · 2013: 176 · 2012: 213
- FWCI
- 60.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca077285-03)
- National Cancer Institute (CA77285)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- pediatric computed tomography, radiation-induced cancer, age at diagnosis, linear no-threshold model, low-dose radiation risk, abdominal CT, head CT, benefits and risks
- MeSH terms
- Adolescent, Cause of Death, Child, Child, Preschool, Female, Humans, Infant, Infant, Newborn, Male, Neoplasms, Radiation-Induced, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review