Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record.

Time Course of Perception and Decision Making During Mammographic Interpretation

Nodine, Calvin F., Mello-Thoms, Claudia, Kundel, Harold L., Weinstein, Susan P.·2002·American Journal of Roentgenology

Abstract

OBJECTIVE: This article describes the time course of lesion detection on digital mammograms using data about both eye position and decision time to compare performance between experienced mammographers and trainees. Research indicates that a longer decision time works against performance in the interpretation of chest radiographs because the likelihood of error is increased, particularly for trainees. Is this relation between decision time and performance also true for interpreting mammograms? Is there an optimal decision time-performance trade-off for detecting breast lesions? MATERIALS AND METHODS: Six radiology trainees (experience, 302-976 cases) and three mammographers (experience, 3000-5000 cases per year) reviewed 40 test cases. Each test case was represented by two mammograms that showed different views of the same breast. Twenty breasts contained suspicious lesions, and 20 were lesion-free. An interactive computer display system with an eye-head tracker measured the timing of decisions, where visual attention was directed, and how much time was spent fixating on a region of interest for each decision. Eye position was monitored during an initial-decision phase, and decision times were measured throughout a final-decision phase during which suspicious lesions recognized initially were interpreted and localized. Performance was analyzed using localization receiver operating characteristic curves. RESULTS: The time course of interpreting mammograms is similar to that for interpreting chest radiographs. Mammographers detected 71% of the true lesions within 25 sec, and trainees detected 46% within 40 sec. Both a fixation dwell time of 1000 msec and a high level of confidence in the decision were associated with the detection of true lesions for the mammographers but not for the trainees. CONCLUSION: Mammographers detected most breast lesions by global recognition within 25 sec, but trainees took more time. Prolonging one's search beyond the global recognition phase yielded few new lesions and increased the risk of error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.179.4.1790917

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Nodine, C. F., Mello-Thoms, C., Kundel, H. L., & Weinstein, S. P.
Venue
American Journal of Roentgenology
Published
2002-10
Volume
179
Issue
4
Pages
917-923
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2141148329
Cited by
189
References
0
FWCI
4.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time Course of Perception and Decision Making During Mammographic Interpretation. https://app.cochat.ai/papers/10.2214/ajr.179.4.1790917
The paper
Nodine, C. F., Mello-Thoms, C., Kundel, H. L., & Weinstein, S. P. (2002). Time Course of Perception and Decision Making During Mammographic Interpretation. American Journal of Roentgenology. https://doi.org/10.2214/ajr.179.4.1790917

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.