The DOI matches its Crossref record.
Grading Articular Cartilage of the Knee Using Fast Spin-Echo Proton Density-Weighted MR Imaging Without Fat Suppression
Abstract
OBJECTIVE: The objective of this work was to determine the accuracy of fast spin-echo proton density-weighted MR imaging in the evaluation of the articular cartilage of the knee using arthroscopy as a gold standard. MATERIALS AND METHODS: We retrospectively reviewed MR images of the knee in 54 patients for whom arthroscopic results were available. All MR imaging studies included fast spin-echo proton density-weighted coronal and axial sequences as part of our routine protocol. Evaluation of the articular surfaces was performed by three independent observers who were unaware of the arthroscopic results. The cartilage surfaces were graded using a 3-point system, and results were compared with arthroscopic findings. RESULTS: Of 324 cartilage surfaces evaluated, arthroscopy showed 241 surfaces as normal, 56 as containing partial-thickness defects, and 27 as containing full-thickness defects. Compared with arthroscopic data, sensitivity of MR imaging for the three reviewers was 59-73.5%; specificity, 86.7-90.5%; positive predictive value, 60.5-72.6%; negative predictive value, 86.0-90.8%; and accuracy, 79.6-86.1%. Interobserver variability for the presence of disease, which was measured using the kappa statistic, was 0.63. CONCLUSION: Fast spin-echo proton density-weighted MR imaging sequences can be used to evaluate the cartilage of the knee with accuracy comparable to that of previously reported cartilage-specific sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kornaat, P. R., Ceulemans, R. Y. T., Kroon, H. M., Riyazi, N., Kloppenburg, M., Carter, W. O., Woodworth, T. G., & Bloem, J. L. (2005) · Skeletal Radiology · doi:10.1007/s00256-004-0828-0 · Cited by 321
Kijowski, R., Davis, K. W., Woods, M. A., Lindstrom, M. J., De Smet, A. A., Gold, G. E., & Busse, R. F. (2009) · Radiology · doi:10.1148/radiol.2523090028 · Cited by 256
Kijowski, R., Blankenbaker, D. G., Munoz del Rio, A., Baer, G. S., & Graf, B. K. (2013) · Radiology · doi:10.1148/radiol.12121413 · Cited by 186
Comparison of 1.5- and 3.0-T MR Imaging for Evaluating the Articular Cartilage of the Knee Joint
Kijowski, R., Blankenbaker, D. G., Davis, K. W., Shinki, K., Kaplan, L. D., & De Smet, A. A. (2009) · Radiology · doi:10.1148/radiol.2503080822 · Cited by 170
Kijowski, R., Blankenbaker, D. G., Klaers, J. L., Shinki, K., De Smet, A. A., & Block, W. F. (2009) · Radiology · doi:10.1148/radiol.2511081133 · Cited by 101
Metadata
- Authors
- Sonin, A. H., Pensy, R. A., Mulligan, M. E., & Hatem, S.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2002-11
- Volume
- 179
- Issue
- 5
- Pages
- 1159-1166
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2019150455
- Cited by
- 158
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grading Articular Cartilage of the Knee Using Fast Spin-Echo Proton Density-Weighted MR Imaging Without Fat Suppression. https://app.cochat.ai/papers/10.2214/ajr.179.5.1791159
- The paper
- Sonin, A. H., Pensy, R. A., Mulligan, M. E., & Hatem, S. (2002). Grading Articular Cartilage of the Knee Using Fast Spin-Echo Proton Density-Weighted MR Imaging Without Fat Suppression. American Journal of Roentgenology. https://doi.org/10.2214/ajr.179.5.1791159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.