Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging—Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T

Open access
Kijowski, Richard, Davis, Kirkland W., Woods, Michael A., Lindstrom, Mary J., De Smet, Arthur A., Gold, Garry E., Busse, Reed F.·2009·Radiology

Abstract

PURPOSE: To determine whether a three-dimensional isotropic resolution fast spin-echo sequence (FSE-Cube) has similar diagnostic performance as a routine magnetic resonance (MR) imaging protocol for evaluating the cartilage, ligaments, menisci, and osseous structures of the knee joint in symptomatic patients at 3.0 T. MATERIALS AND METHODS: This prospective, HIPAA-compliant, institutional review board-approved study was performed with a waiver of informed consent. FSE-Cube was added to the routine 3.0-T MR imaging protocol performed in 100 symptomatic patients (54 male patients with a median age of 32 years and 46 female patients with a median age of 33 years) who subsequently underwent arthroscopic knee surgery. All MR imaging studies were independently reviewed twice by two musculoskeletal radiologists. During the first review, the routine MR imaging protocol was used to detect cartilage lesions, ligament tears, meniscal tears, and bone marrow edema lesions. During the second review, FSE-Cube with multiplanar reformations was used to detect these joint abnormalities. With arthroscopic results as the reference standard, the sensitivity and specificity of FSE-Cube and the routine MR imaging protocol in the detection of cartilage lesions, anterior cruciate ligament tears, and meniscal tears were calculated. Permutation tests were used to compare sensitivity and specificity values. RESULTS: FSE-Cube had significantly higher sensitivity (P = .039) but significantly lower specificity (P = .003) than the routine MR imaging protocol for detecting cartilage lesions. There were no significant differences (P = .183-.999) in sensitivity and specificity between FSE-Cube and the routine MR imaging protocol in the detection of anterior cruciate ligament tears, medial meniscal tears, or lateral meniscal tears. FSE-Cube depicted 96.2% of medial collateral ligament tears, 100% of lateral collateral ligament tears, and 85.3% of bone marrow edema lesions identified on images obtained with the routine MR imaging protocol. CONCLUSION: FSE-Cube has similar diagnostic performance as a routine MR imaging protocol for detecting cartilage lesions, cruciate ligament tears, collateral ligament tears, meniscal tears, and bone marrow edema lesions within the knee joint at 3.0 T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2523090028

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 256

Metadata

Authors
Kijowski, R., Davis, K. W., Woods, M. A., Lindstrom, M. J., De Smet, A. A., Gold, G. E., & Busse, R. F.
Venue
Radiology
Published
2009-08
Volume
252
Issue
2
Pages
486-495
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2167944645
Cited by
256
References
17
FWCI
18.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging—Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T. https://app.cochat.ai/papers/10.1148/radiol.2523090028
The paper
Kijowski, R., Davis, K. W., Woods, M. A., Lindstrom, M. J., De Smet, A. A., Gold, G. E., & Busse, R. F. (2009). Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging—Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T. Radiology. https://doi.org/10.1148/radiol.2523090028

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.