Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 225

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic

Tack, Denis, Sourtzis, Stavroula, Delpierre, Isabelle, de Maertelaer, Viviane, Gevenois, Pierre Alain · 2003 · American Journal of Roentgenology

Abstract

OBJECTIVE: This study is designed to assess the intraobserver and interobserver agreements and the diagnostic performances of low-dose unenhanced multidetector CT (MDCT) in patients with suspected renal colic. SUBJECTS AND METHODS: The study included 106 patients who underwent unenhanced MDCT with 4 x 2.5 mm collimation, 120 kVp, 30 mAs, and, if necessary, additional focused acquisitions at 60 or 120 mAs on areas with an equivocal ureteral stone or with significant image noise. The effective radiation dose was computer-simulated with software based on the Monte Carlo model and International Commission on Radiological Protection recommendations. CT scans were archived and independently reviewed by three radiologists during two interpretation sessions on a workstation with three dimensions functions. Intraobserver and interobserver agreements were calculated with the kappa statistics. Accuracy for detection of ureteral stone on low-dose MDCT was calculated by comparison with combined clinical (stone passage), surgical (stone retrieval, extracorporeal shock wave lithotripsy), biologic (urinalysis, urine culture), and other imaging (excretory urography, standard-dose MDCT, follow-up sonography, and abdominal radiography) findings or by evidence for an alternative diagnosis. RESULTS: Ureteral stones were present in 38 (36%) of 106 patients. Thirty-six of 38 ureteral stones were detected by low-dose MDCT. From reviewer to reviewer, the number of true-positive, false-positive, true-negative, and false-negative findings ranged, respectively, from 34 to 36, 1 to 4, 64 to 68, and 2 to 4. The corresponding sensitivity, specificity, and accuracy ranged from 89.5% to 94.7%, from 94.1% to 100%, and from 93.4% to 98.1%, respectively. The intraobserver and interobserver agreements were excellent, with kappa values ranging from 0.87 to 0.98. In 13 patients, an alternative diagnosis explaining the patient's symptoms was proposed by all reviewers using images obtained at 30 mAs. No additional or alternative diagnosis was found at standard dose. At 30 mAs, the mean effective dose was 1.2 mSv in men and 1.9 mSv in women. Additional acquisitions at 60 mAs, all focused on the lower pelvis, were acquired in 20 patients, but the corresponding images were needed by the reviewers for only six of them. The acquisitions at 60 mAs were responsible for an additional mean effective dose of 0.5 in men and 0.8 mSv in women. CONCLUSION: Our study shows that low-dose unenhanced MDCT is appropriate for the diagnosis of ureteral stones, and that it provides excellent intraobserver and interobserver agreements and does not obscure alternative diagnoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.180.2.1800305

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A.
Venue
American Journal of Roentgenology
Published
2003-02
Volume
180
Issue
2
Pages
305-311
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1982153365
Cited by
225
References
1
FWCI
14.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic. https://app.cochat.ai/papers/10.2214/ajr.180.2.1800305
The paper
Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A. (2003). Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic. American Journal of Roentgenology. https://doi.org/10.2214/ajr.180.2.1800305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.