Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: This study is designed to assess the intraobserver and interobserver agreements and the diagnostic performances of low-dose unenhanced multidetector CT (MDCT) in patients with suspected renal colic. SUBJECTS AND METHODS: The study included 106 patients who underwent unenhanced MDCT with 4 x 2.5 mm collimation, 120 kVp, 30 mAs, and, if necessary, additional focused acquisitions at 60 or 120 mAs on areas with an equivocal ureteral stone or with significant image noise. The effective radiation dose was computer-simulated with software based on the Monte Carlo model and International Commission on Radiological Protection recommendations. CT scans were archived and independently reviewed by three radiologists during two interpretation sessions on a workstation with three dimensions functions. Intraobserver and interobserver agreements were calculated with the kappa statistics. Accuracy for detection of ureteral stone on low-dose MDCT was calculated by comparison with combined clinical (stone passage), surgical (stone retrieval, extracorporeal shock wave lithotripsy), biologic (urinalysis, urine culture), and other imaging (excretory urography, standard-dose MDCT, follow-up sonography, and abdominal radiography) findings or by evidence for an alternative diagnosis. RESULTS: Ureteral stones were present in 38 (36%) of 106 patients. Thirty-six of 38 ureteral stones were detected by low-dose MDCT. From reviewer to reviewer, the number of true-positive, false-positive, true-negative, and false-negative findings ranged, respectively, from 34 to 36, 1 to 4, 64 to 68, and 2 to 4. The corresponding sensitivity, specificity, and accuracy ranged from 89.5% to 94.7%, from 94.1% to 100%, and from 93.4% to 98.1%, respectively. The intraobserver and interobserver agreements were excellent, with kappa values ranging from 0.87 to 0.98. In 13 patients, an alternative diagnosis explaining the patient's symptoms was proposed by all reviewers using images obtained at 30 mAs. No additional or alternative diagnosis was found at standard dose. At 30 mAs, the mean effective dose was 1.2 mSv in men and 1.9 mSv in women. Additional acquisitions at 60 mAs, all focused on the lower pelvis, were acquired in 20 patients, but the corresponding images were needed by the reviewers for only six of them. The acquisitions at 60 mAs were responsible for an additional mean effective dose of 0.5 in men and 0.8 mSv in women. CONCLUSION: Our study shows that low-dose unenhanced MDCT is appropriate for the diagnosis of ureteral stones, and that it provides excellent intraobserver and interobserver agreements and does not obscure alternative diagnoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Statistical Tables for Biological, Agricultural and Medical Research.
Reed, L. J., Fisher, R. A., & Yates, F. (1944) · Journal of the American Statistical Association · doi:10.2307/2280633 · Cited by 2,998
Basic and Clinical Biostatistics,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00360-0 · Cited by 1,809
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Brown, A. S., Brummel‐Smith, K., Burgess, L., D'Agostino, R. B., Goldschmidt, J. W., Halter, J. B., Hazzard, W. R., Jahnigen, D. W., Phelps, C., Raskind, M., et al. (1988) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1988.tb02362.x · Cited by 1,331
Klockars, A., & Sax, G. (1986) · Sage eBooks · doi:10.4135/9781412985185 · Cited by 1,013
Quantitative Applications in the Social Sciences: Multiattribute Evaluation
Rand, G. K. (1983) · Journal of the Operational Research Society · doi:10.1057/jors.1983.225 · Cited by 837
Health implications of obesity
Pi-Sunyer, F. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.6.1595s · Cited by 809
Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography.
Smith, R. C., Rosenfield, A. T., Choe, K. A., Essenmacher, K. R., Verga, M., Glickman, M. G., & Lange, R. C. (1995) · Radiology · doi:10.1148/radiology.194.3.7862980 · Cited by 671
Appendicitis at the Millennium
Birnbaum, B. A., & Wilson, S. R. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma24337 · Cited by 631
OBESITY, N. I. O. H. C. D. P. O. T. H. I. O. (1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-6-1073 · Cited by 470
CT Evaluation of the Colon: Inflammatory Disease
Horton, K. M., Corl, F. M., & Fishman, E. K. (2000) · RadioGraphics · doi:10.1148/radiographics.20.2.g00mc15399 · Cited by 441
Wall, B. F., & Hart, D. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.833.9227222 · Cited by 412
Musset, D., Parent, F., Meyer, G., Maître, S., Girard, P., Leroyer, C., Revel, M.-P., Carette, M.-F., Laurent, M., Charbonnier, B., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11914-3 · Cited by 402
Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?
Ghaye, B., Szapiro, D., Mastora, I., Delannoy, V., Duhamel, A., Remy, J., & Remy-Jardin, M. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn32629 · Cited by 344
Kachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
Gies, M., Kalender, W. A., Wolf, H., Suess, C., & Madsen, M. T. (1999) · Medical Physics · doi:10.1118/1.598779 · Cited by 306
Urinary Tract Abnormalities: Initial Experience with Multi–Detector Row CT Urography
Caoili, E. M., Cohan, R. H., KOROBKIN, M. T., Platt, J. F., Francis, I. R., Faerber, G. J., Montie, J. E., & Ellis, J. H. (2002) · Radiology · doi:10.1148/radiol.2222010667 · Cited by 306
Ambrosetti, P., Becker, C., & Terrier, F. (2002) · European Radiology · doi:10.1007/s00330-001-1143-y · Cited by 284
Pulmonary Embolism: Optimization of Small Pulmonary Artery Visualization at Multi–Detector Row CT
Patel, S., Kazerooni, E. A., & Cascade, P. N. (2003) · Radiology · doi:10.1148/radiol.2272011139 · Cited by 274
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
A PC program for estimating organ dose and effective dose values in computed tomography
Kalender, W. A., Schmidt, B., Zankl, M., & Schmidt, M. (1999) · European Radiology · doi:10.1007/s003300050709 · Cited by 231
Greess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230
Computed tomography in the evaluation of diverticulitis.
Hulnick, D. H., Megibow, A. J., Balthazar, E. J., Naidich, D. P., & Bosniak, M. A. (1984) · Radiology · doi:10.1148/radiology.152.2.6739821 · Cited by 225
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Cancer Risk from Low-Level Radiation
Cohen, B. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791137 · Cited by 195
Greess, H., Nömayr, A., Wolf, H., Baum, U., Lell, M., Böwing, B., Kalender, W., & Bautz, W. A. (2002) · European Radiology · doi:10.1007/s00330-001-1255-4 · Cited by 192
CT of the chest: minimal tube current required for good image quality with the least radiation dose.
Mayo, J. R., Hartman, T. E., Lee, K. S., Primack, S. L., Vedal, S., & Müller, N. L. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.3.7863879 · Cited by 154
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
Radiation Dose Management: Weighing Risk Versus Benefit
Haaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Radiation Exposure and Image Quality in Chest CT Examinations
Ravenel, J. G., Scalzetti, E. M., Huda, W., & Garrisi, W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770279 · Cited by 142
Radiation dose in CT: are we meeting the challenge?
Golding, S. J., & Shrimpton, P. C. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.889.750001 · Cited by 139
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Mahesh, M., Scatarige, J. C., Cooper, J., & Fishman, E. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771273 · Cited by 138
REEXAMINING THE VALUE OF HEMATURIA TESTING IN PATIENTS WITH ACUTE FLANK PAIN
Bove, P. F., KAPLAN, D., Dalrymple, N. C., Rosenfield, A. T., VERGA, M., ANDERSON, K., & Smith, R. C. (1999) · The Journal of Urology · doi:10.1097/00005392-199909010-00013 · Cited by 106
Common Terminology for Single and Multislice Helical CT
Silverman, P. M., Kalender, W. A., & Hazle, J. D. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.5.1761135 · Cited by 96
ABC of labour care: Relief of pain
Findley, I., & Chamberlain, G. V. P. (1999) · BMJ · doi:10.1136/bmj.318.7188.927 · Cited by 92
Hein, E., Rogalla, P., Klingebiel, R., & Hamm, B. (2002) · European Radiology · doi:10.1007/s00330-001-1279-9 · Cited by 80
Lung Cancer Screening: Minimum Tube Current Required for Helical CT
Itoh, S., Ikeda, M., Arahata, S., Kodaira, T., Isomura, T., Kato, T., Yamakawa, K., Maruyama, K., & Ishigaki, T. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap16175 · Cited by 78
Diagnostic medical exposures in the U.K.
Shrimpton, P. C., Wall, B. F., & Hart, D. B. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00028-1 · Cited by 72
Abramson, S., Walders, N., Applegate, K. E., Gilkeson, R., & Robbin, M. R. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.6.1751689 · Cited by 67
Perforations of the rectosigmoid colon induced by cleansing enema: CT findings in 14 patients
Gayer, G., Zissin, R., Apter, S., Oscadchy, A., & Hertz, M. (2002) · Abdominal Imaging · doi:10.1007/s00261-001-0104-x · Cited by 39
Low-dose CT of the thorax in cancer follow-up
Yamada, T., Ono, S., Tsuboi, M., Saito, H., Sato, A., Matsuhashi, T., Ishibashi, T., & Takahashi, S. (2003) · European Journal of Radiology · doi:10.1016/j.ejrad.2003.09.017 · Cited by 22
Aquino, S. L., & Fischman, A. J. (2004) · CHEST Journal · doi:10.1378/chest.126.3.755 · Cited by 16
Cited by
Patel, S. J., Reede, D. L., Katz, D. S., Subramaniam, R., & Amorosa, J. K. (2007) · RadioGraphics · doi:10.1148/rg.276075002 · Cited by 460
Low-Dose Versus Standard-Dose CT Protocol in Patients with Clinically Suspected Renal Colic
Poletti, P.-A., Platon, A., Rutschmann, O. T., Schmidlin, F. R., Iselin, C. E., & Becker, C. D. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0793 · Cited by 371
Rehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis
Niemann, T., Kollmann, T., & Bongartz, G. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3414 · Cited by 296
Kluner, C., Hein, P. A., Gralla, O., Hein, E., Hamm, B., Romano, V., & Rogalla, P. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000191685.58838.ef · Cited by 171
“…Ruppert-Kohlmayr et al, 1999 4.3 Becker et al, 1999 8.8 Cohnen et al, 2003 12.4/16.1 Low-dose CT Liu et al, 2000 2.76/2.82 Hamm et al, 2001 0.98/1.5 Tack et al, 2003 1.2/1.9 Knopfle et al, 2003 0.97/1.35 Present study 0.5/0.7 q 2006 Lippincott Williams & Wilkins 45 Copyright © Lippincott Williams…”
Influential
Metadata
- Authors
- Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2003-02
- Volume
- 180
- Issue
- 2
- Pages
- 305-311
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1982153365
- Cited by
- 225
- References
- 45
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.