Characterization of Adnexal Mass Lesions on MR Imaging
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of our study was to evaluate the accuracy of MR imaging in the detection and characterization of adnexal mass lesions and to determine which imaging features are predictive of malignancy. SUBJECTS AND METHODS: We prospectively performed MR imaging in 104 patients (age range, 19-87 years; mean age, 50 years) with clinically or sonographically detected complex adnexal masses. We used a 1.5-T unit to perform T1-, T2-, and fat-suppressed T1-weighted sequences before and after IV injection of gadolinium. The adnexal lesions were examined for several features including size, shape, character (solid-cystic), vegetation, signal intensity, and enhancement. Secondary signs such as ascites, peritoneal disease, and lymphadenopathy were noted. We compared the imaging features with the surgical and pathologic findings. Multiple logistic regression analysis was performed on all MR imaging features. RESULTS: A total of 163 lesions--94 benign and 69 malignant lesions--were examined. On MR imaging, 95% (155/163) of the lesions were detected. The overall accuracy for the diagnosis of malignancy was 91%. On univariate analysis, the imaging features associated with malignancy were a solid-cystic lesion, irregularity, and vegetation on the wall and septum in a cystic lesion, the large size of the lesion, an early enhancement on dynamic contrast-enhanced MR images, and the presence of ascites, peritoneal disease, or adenopathy. On multiple logistic regression analysis, ascites and vegetation in a cystic lesion were the factors most significantly indicative of malignancy. CONCLUSION: MR imaging is highly accurate in the characterization of adnexal mass lesions, and the best predictors of malignancy are vegetation in a cystic lesion and ascites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Complex Adnexal Masses: Detection and Characterization with MR Imaging—Multivariate Analysis
Hricak, H., Chen, M., Coakley, F. V., Kinkel, K., Yu, K. K., Sica, G., Bacchetti, P., & Powell, C. B. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja3939 · Cited by 294
Padhani, A. R., & Husband, J. E. (2001) · Clinical Radiology · doi:10.1053/crad.2001.0762 · Cited by 230
Valentin, L., Hagen, B., Tingulstad, S., & Eik‐Nes, S. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00500.x · Cited by 227
Timmerman, D., Bourne, T. H., Tailor, A., Collins, W. P., Verrelst, H., Vandenberghe, K., & Vergote, I. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70436-9 · Cited by 159
Distinguishing the Benign and Malignant Adnexal Mass: An External Validation of Prognostic Models
Mol, B. W., Boll, D., Kanter, M. D., Heintz, A. P. M., Sijmons, E. A., Oei, S. G., Bal, H., & Brölmann, H. A. M. (2001) · Gynecologic Oncology · doi:10.1006/gyno.2000.6052 · Cited by 109
Prospective Evaluation of Logistic Regression Models for the Diagnosis of Ovarian Cancer
Aslam, N., BANERJEE, S., CARR, J. V., SAVVAS, M., HOOPER, R., & Jurkovic, D. (2000) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(00)00835-8 · Cited by 71
Transvaginal color Doppler ultrasonography and CA‐125 in suspicious adnexal masses
Alcázar, J. L., Errasti, T., Zornoza, A., Mínguez, J. Á., & Galán, M. J. P. (1999) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(99)00104-6 · Cited by 23
Cited by
Sala, E., Rockall, A. G., Freeman, S. J., Mitchell, D. G., & Reinhold, C. (2013) · Radiology · doi:10.1148/radiol.12120315 · Cited by 347
Adnexal Masses: Development and Preliminary Validation of an MR Imaging Scoring System
Thomassin-Naggara, I., Aubert, E., Rockall, A., Jalaguier-Coudray, A., Rouzier, R., Daraï, E., & Bazot, M. (2013) · Radiology · doi:10.1148/radiol.13121161 · Cited by 223
Sadowski, E. A., Thomassin-Naggara, I., Rockall, A., Maturen, K. E., Forstner, R., Jha, P., Nougaret, S., Siegelman, E. S., & Reinhold, C. (2022) · Radiology · doi:10.1148/radiol.204371 · Cited by 207
Thomassin-Naggara, I., Bazot, M., Daraï, E., Callard, P., Thomassin, J., & Cuenod, C. A. (2008) · Radiology · doi:10.1148/radiol.2481071120 · Cited by 201
“The criteria used to show the malignancy of ovarian tumors on US and morphologic MR images are septations, vegetations, and solid portions (4,6,29,30).”
BackgroundMethodThomassin-Naggara, I., Toussaint, I., Perrot, N., Rouzier, R., Cuenod, C. A., Bazot, M., & Daraï, E. (2011) · Radiology · doi:10.1148/radiol.10100751 · Cited by 195
Contribution of diffusion-weighted MR imaging for predicting benignity of complex adnexal masses
Thomassin-Naggara, I., Daraï, E., Cuenod, C. A., Fournier, L., Toussaint, I., Marsault, C., & Bazot, M. (2009) · European Radiology · doi:10.1007/s00330-009-1299-4 · Cited by 190
“Our study confirms that low T2 signal intensity within a solid component is a good criterion for predicting benignity of ultrasonographically indeterminate or complex masses [8, 31, 33].”
BackgroundThomassin‐Naggara, I., Daraï, E., Cuenod, C. A., Rouzier, R., Callard, P., & Bazot, M. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21377 · Cited by 175
“Some studies have suggested that post-contrast-enhanced MRI is superior to nonenhanced MRI for ovarian tumor characterization (11,13,22).”
BackgroundMethodResultInfluentialThe role of magnetic resonance imaging and ultrasound in patients with adnexal masses
Sohaib, S. A., Mills, T. D., Sahdev, A., Webb, J. A. W., VanTrappen, P. O., Jacobs, I. J., & Reznek, R. H. (2005) · Clinical Radiology · doi:10.1016/j.crad.2004.09.007 · Cited by 171
Self-citation
Metadata
- Authors
- Sohaib, S. A. A., Sahdev, A., Trappen, P. V., Jacobs, I. J., & Reznek, R. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2003-05
- Volume
- 180
- Issue
- 5
- Pages
- 1297-1304
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2126569050
- Cited by
- 222
- References
- 9
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.