CoChat

Detection of Small Pancreatic Tumors with Multiphasic Helical CT

Bronstein, Yulia Lisenko, Loyer, Evelyne M., Kaur, Harmeet, Choi, Haesun, David, Cynthia, DuBrow, Ronelle A., Broemeling, Lyle D., Cleary, Karen R., Charnsangavej, Chusilp · 2004 · American Journal of Roentgenology
Cited by 241

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The purpose of this study was to evaluate the sensitivity and specificity of helical CT in the detection of adenocarcinomas of the pancreas measuring 2 cm or smaller at pathologic examination. MATERIALS AND METHODS: Thin-section triple phase (20, 40, and 70 sec after the start of injection) contrast-enhanced helical CT scans of the abdomen in 18 patients with a pancreatic carcinoma that was 2 cm or smaller and 18 patients with a normal pancreas were retrospectively reviewed by two senior radiologists who specialized in oncologic abdominal imaging. Discrepancies were resolved by consensus. The observers were unaware of the clinical information. CT scans were evaluated for the presence of a pancreatic mass, bile, and pancreatic duct stricture. The location and size of tumors as determined on CT were compared with pathologic findings. The CT results were also compared with the prospective CT interpretations derived from the radiology reports and with the endoscopic sonographic reports when available. RESULTS: The sensitivity of thin-section triple-phase helical CT in the detection of small pancreatic masses was 77%, and the specificity was 100% for the two experienced observers. The sensitivity and specificity were 72% and 100%, respectively, for the prospective interpretations done by 10 observers. There was no correlation between the tumor size at pathology and the CT measurements. CONCLUSION: Thin-section contrast-enhanced helical CT is sensitive and highly specific for the detection of pancreatic tumors measuring 2 cm or smaller. Improvement in the detection rate of this technique compared with previous techniques lies in the optimization of parenchymal enhancement during the pancreatic phase and the decrease in slice thickness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.182.3.1820619

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Bronstein, Y. L., Loyer, E. M., Kaur, H., Choi, H., David, C., DuBrow, R. A., Broemeling, L. D., Cleary, K. R., & Charnsangavej, C.
Venue
American Journal of Roentgenology
Published
2004-03
Volume
182
Issue
3
Pages
619-623
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2031732226
Cited by
241
References
17
FWCI
4.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.