Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
An optimized DL model allowed acceleration of knee images that performed interchangeably with standard images for detection of internal derangement of the knee. Importantly, readers preferred the quality of accelerated images to that of standard clinical images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892 · cited 1×
“The parameters of the model were estimated by minimizing structural similarity index (SSIM) scores on the training set [27].”
MethodSparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611 · cited 1×
“When magnetic field gradients are used to encode spatial information, each data point takes time to acquire [6].”
BackgroundSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationLearning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713 · cited 5×
“In a 2018 study that examined multiple sequences, separate specialized reconstruction models were trained for each individual sequence [12].”
BackgroundMethodSelf-citationImage reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392 · cited 1×
“Second, instead of using the ESPIRiT algorithm to estimate sensitivity maps, we included an additional U-Net to estimate these maps from the input k-space data [26].”
MethodA deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
Convolutional Recurrent Neural Networks for Dynamic MR Image Reconstruction
Qin, C., Schlemper, J., Caballero, J., Price, A. N., Hajnal, J. V., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2863670 · Cited by 603
Deep Generative Adversarial Neural Networks for Compressive Sensing MRI
Mardani, M., Gong, E., Cheng, J. Y., Vasanawala, S. S., Zaharchuk, G., Xing, L., & Pauly, J. M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2858752 · Cited by 552
Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.
Pc, L. (1989) · PubMed · Cited by 391
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
MR Imaging of the Menisci and Cruciate Ligaments: A Systematic Review
Oei, E. H. G., Nikken, J. J., Verstijnen, A. C. M., Ginai, A. Z., & Myriam Hunink, M. G. (2003) · Radiology · doi:10.1148/radiol.2263011892 · Cited by 371 · cited 1×
“Previous studies, however, have reported excellent accuracy of MRI for the detection of internal derangement of the knee [33].”
ResultDeep Convolutional Framelets: A General Deep Learning Framework for Inverse Problems
Ye, J. C., Han, Y., & Cha, E. (2018) · SIAM Journal on Imaging Sciences · doi:10.1137/17m1141771 · Cited by 330
Floriani, I., Torri, V., Rulli, E., Garavaglia, D., Compagnoni, A., Salvolini, L., & Giovagnoni, A. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22010 · Cited by 277
Knoll, F., Hammernik, K., Kobler, E., Pock, T., Recht, M. P., & Sodickson, D. K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27355 · Cited by 217
Self-citationGielen, J., de Schepper, A. M., Vanhoenacker, F. M. H. M., Parizel, P. M., Wang, X. L., Sciot, R., & Weyler, J. (2004) · European Radiology · doi:10.1007/s00330-004-2431-0 · Cited by 143
Chen, F., Taviani, V., Malkiel, I., Cheng, J. Y., Tamir, J. I., Shaikh, J., Chang, S. T., Hardy, C. J., Pauly, J. M., & Vasanawala, S. S. (2018) · Radiology · doi:10.1148/radiol.2018180445 · Cited by 129 · cited 1×
“Studies have shown progress toward achieving acceptable image quality with a small number of subjects, but a study showing both high quality and high accuracy has not been reported to our knowledge [12, 21] (Knoll F, et al.”
BackgroundUse of Radiography in Acute Knee Injuries: Need for Clinical Decision Rules
Stiell, I. G., Wells, G. A., McDowell, I., Greenberg, G. H., McKnight, R. D., Cwinn, A. A., Quinn, J., & Yeats, A. (1995) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1995.tb03123.x · Cited by 94 · cited 1×
“Currently, radiography is the first step in imaging patients with acute knee trauma because of short examination time and low cost, despite its extremely low sensitivity for such injuries and its use of ionizing radiation [32].”
BackgroundFunctional MR Neurography in Evaluation of Peripheral Nerve Trauma and Postsurgical Assessment
Martín‐Noguerol, T., Barousse, R., Cabrera, M. G., et al. (2019) · Radiographics · doi:10.1148/rg.2019180112 · Cited by 75
Testing for Interchangeability of Imaging Tests
Obuchowski, N. A., Subhas, N., & Schoenhagen, P. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.07.004 · Cited by 61 · cited 2×
“Interchangeability Study Once all parameters were optimized, an interchangeability study was performed on the 108 test patients’ examinations [30].”
BackgroundMethodRecht, M. P., Block, K. T., Chandarana, H., Friedland, J., Mulholland, T., Teahan, D., & Wiggins, R. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20459 · Cited by 42 · cited 1×
“Although time spent on activities other than imaging has previously accounted for a significant percentage of total MRI examination time, recently described innovative workflow solutions such as dockable tables and dedicated preparation rooms have enabled the time for these activities to be decreased to less than 2 mi…”
BackgroundSelf-citationSchnaiter, J., Roemer, F. W., McKenna-Kuettner, A., Patzak, H. J., May, M. S., Janka, R., Uder, M., & Wuest, W. (2017) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0043-119038 · Cited by 28 · cited 1×
“For most clinical examinations, the maximum acceptable acceleration factor is 2 [10].”
Background
Cited by
Results of the 2020 fastMRI challenge for machine learning MR image reconstruction
Muckley, M. J., Riemenschneider, B., Radmanesh, A., Kim, S., Jeong, G., Ko, J., Jun, Y., Shin, H., Hwang, D., Mostapha, M., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3075856 · Cited by 313
“This model also provided improvement over the baseline [14], which had previously been demonstrated for clinical interchangeability at 4X for knee imaging [48].”
BackgroundMethodSelf-citationLow-count whole-body PET with deep learning in a multicenter and externally validated study
Chaudhari, A. S., Mittra, E., Davidzon, G. A., Gulaka, P., Gandhi, H., Brown, A., Zhang, T., Srinivas, S., Gong, E., Zaharchuk, G., et al. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00497-2 · Cited by 83
Pierre, K., Haneberg, A. G., Kwak, S., Peters, K. R., Hochhegger, B., Sananmuang, T., Tunlayadechanont, P., Tighe, P. J., Mancuso, A., & Forghani, R. (2023) · Seminars in Roentgenology · doi:10.1053/j.ro.2023.02.003 · Cited by 79
Metadata
- Authors
- Recht, M. P., Zbontar, J., Sodickson, D. K., Knoll, F., Yakubova, N., Sriram, A., Murrell, T., Defazio, A., Rabbat, M., Rybak, L., Kline, M., Ciavarra, G., Alaia, E. F., Samim, M., Walter, W. R., Lin, D. J., Lui, Y. W., Muckley, M., Huang, Z., Johnson, P., Stern, R., & Zitnick, C. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2020-12
- Volume
- 215
- Issue
- 6
- Pages
- 1421-1429
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W3041796785
- Cited by
- 174
- References
- 27
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.