Low-count whole-body PET with deep learning in a multicenter and externally validated study

Open access
Chaudhari, Akshay S., Mittra, Erik, Davidzon, Guido A., Gulaka, Praveen, Gandhi, Harsh, Brown, Adam, Zhang, Tao, Srinivas, Shyam +3 more·2021·npj Digital Medicine

Abstract

More widespread use of positron emission tomography (PET) imaging is limited by its high cost and radiation dose. Reductions in PET scan time or radiotracer dosage typically degrade diagnostic image quality (DIQ). Deep-learning-based reconstruction may improve DIQ, but such methods have not been clinically evaluated in a realistic multicenter, multivendor environment. In this study, we evaluated the performance and generalizability of a deep-learning-based image-quality enhancement algorithm applied to fourfold reduced-count whole-body PET in a realistic clinical oncologic imaging environment with multiple blinded readers, institutions, and scanner types. We demonstrate that the low-count-enhanced scans were noninferior to the standard scans in DIQ (p < 0.05) and overall diagnostic confidence (p < 0.001) independent of the underlying PET scanner used. Lesion detection for the low-count-enhanced scans had a high patient-level sensitivity of 0.94 (0.83–0.99) and specificity of 0.98 (0.95–0.99). Interscan kappa agreement of 0.85 was comparable to intrareader (0.88) and pairwise inter-reader agreements (maximum of 0.72). SUV quantification was comparable in the reference regions and lesions (lowest p-value=0.59) and had high correlation (lowest CCC = 0.94). Thus, we demonstrated that deep learning can be used to restore diagnostic image quality and maintain SUV accuracy for fourfold reduced-count PET scans, with interscan variations in lesion depiction, lower than intra- and interreader variations. This method generalized to an external validation set of clinical patients from multiple institutions and scanner types. Overall, this method may enable either dose or exam-duration reduction, increasing safety and lowering the cost of PET imaging.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-021-00497-2

Cites

0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The success of deep learning in computer vision analysis has significantly advanced its clinical applications in comprehending biomedical images, including CT scans, PET-CT scans, whole-slide images, and MRI scans.

    “The success of deep learning in computer vision (CV) analysis has significantly advanced its clinical applications in comprehending biomedical images, including CT scans [88], positron emission tomography (PET)-CT scans [89], whole-slide images (WSIs) [90], and MRI scans [91].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 34

  1. [1]Gallamini A Zwarthoed C Borra A Positron emission tomography (PET) in oncology Cancers 2014 6 1821 1889 10.3390/cancers6041821 25268160 PMC4276948 · DOI
  2. [2]Zasadny, K. R. & Wahl, R. L. Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction. Radiology189, 847–950 (1993). 8234714
  3. [3]Strauss L Conti PS The applications of PET in clinical oncology J. Nucl. Med. 1991 32 623 650 2013803
  4. [4]Thie JA Understanding the standardized uptake value, its methods, and implications for usage J. Nucl. Med. 2004 45 1431 1434 15347707
  5. [5]Chen KT MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects J. Magn. Reson. Imaging 2018 48 1288 1296 10.1002/jmri.26000 29517819 PMC6129224 · DOI
  6. [6]Callahan J Binns D Dunn L Kron T Motion effects on SUV and lesion volume in 3D and 4D PET scanning Australas. Phys. Eng. Sci. Med. 2011 34 489 495 10.1007/s13246-011-0109-x 22081269 · DOI
  7. [8]Pearce MS Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study Lancet 2012 380 499 505 10.1016/S0140-6736(12)60815-0 22681860 PMC3418594 · DOI · Paper page
  8. [9]Roberts FO Radiation dose to PET technologists and strategies to lower occupational exposure J. Nucl. Med. Technol. 2005 33 44 47 15731021
  9. [10]Huang B Law MWM Khong PL Whole-body PET/CT scanning: estimation of radiation dose and cancer risk Radiology 2009 251 166 174 10.1148/radiol.2511081300 19251940 · DOI
  10. [11]Ardila D End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography Nat. Med. 2019 25 954 961 10.1038/s41591-019-0447-x 31110349 · DOI · Paper page
  11. [12]McKinney SM International evaluation of an AI system for breast cancer screening Nature 2020 577 89 94 10.1038/s41586-019-1799-6 31894144 · DOI · Paper page
  12. [13]Campanella G Clinical-grade computational pathology using weakly supervised deep learning on whole slide images Nat. Med. 2019 25 1301 1309 10.1038/s41591-019-0508-1 31308507 PMC7418463 · DOI · Paper page
  13. [14]Esteva A Dermatologist-level classification of skin cancer with deep neural networks Nature 2017 542 115 118 10.1038/nature21056 28117445 PMC8382232 · DOI · Paper page
  14. [15]Chen H Low-Dose CT with a residual encoder-decoder convolutional neural network IEEE Trans. Med. Imaging 2017 36 2524 2535 10.1109/TMI.2017.2715284 28622671 PMC5727581 · DOI
  15. [17]Kaplan S Zhu Y Full-dose PET image estimation from low-dose PET image using deep learning: a pilot study J. Digit. Imaging 2019 32 773 778 10.1007/s10278-018-0150-3 30402670 PMC6737135 · DOI
  16. [18]Kang J Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images Med. Phys. 2015 42 5301 5309 10.1118/1.4928400 26328979 PMC4545052 · DOI
  17. [19]Chen KT Ultra-low-dose 18F-florbetaben amyloid PET imaging using deep learning with multi-contrast MRI inputs Radiology 2019 290 649 656 10.1148/radiol.2018180940 30526350 PMC6394782 · DOI
  18. [20]Wang Y 3D conditional generative adversarial networks for high-quality PET image estimation at low dose Neuroimage 2018 174 550 562 10.1016/j.neuroimage.2018.03.045 29571715 PMC6410574 · DOI
  19. [21]Wang, Y. R. (Joyce) et al. Artificial intelligence enables whole-body positron emission tomography scans with minimalradiation exposure. Eur. J. Nucl. Med. Mol. Imaging Aug; 48:2771-2781. (2021). PMC8266729 33527176
  20. [22]Recht M. P. et al. Using Deep Learning to Accelerate Knee MRI at 3 T: Results of an Interchangeability Study. AJR Am J Roentgenol 215:1421-1429 (2020). PMC8209682 32755163
  21. [23]Chaudhari, A. S. et al. Diagnostic accuracy of quantitative multi-contrast 5-minute knee MRI using prospective artificial intelligence image quality enhancement title. Am. J. Roentgenol. 216, 1614–1625 (2021). PMC8862596 32755384
  22. [24]Akamatsu G Improvement in PET/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters J. Nucl. Med. 2012 53 1716 1722 10.2967/jnumed.112.103861 22952340 · DOI · Paper page
  23. [25]Neyshabur B Bhojanapalli S McAllester D Srebro N Exploring generalization in deep learning Adv. Neural Inf. Process. Syst. 2017 2017 5948 5957
  24. [27]Paschali, M., Conjeti, S., Navarro, F. & Navab, N. Generalizability vs. robustness: investigating medical imaging networks using adversarial examples. Med. Image Comput. Comput. Assist. Interv. 10.1007/978-3-030-00928-1_56 (2018). · DOI
  25. [29]Julious SA Sample sizes for clinical trials with Normal data Stat. Med. 2004 23 1921 1986 10.1002/sim.1783 15195324 · DOI · Paper page
  26. [31]Gatidis S Towards tracer dose reduction in PET studies: simulation of dose reduction by retrospective randomized undersampling of list-mode data Hell. J. Nucl. Med. 2016 19 15 18 26929936
  27. [32]Seith F Simulation of tracer dose reduction in 18F-FDG PET/MRI: effects on oncologic reading, image quality, and artifacts J. Nucl. Med. 2017 58 1699 1705 10.2967/jnumed.116.184440 28360205 · DOI
  28. [33]Schaefferkoetter JD Quantitative accuracy and lesion detectability of low-dose 18F-FDG PET for lung cancer screening J. Nucl. Med. 2017 58 399 405 10.2967/jnumed.116.177592 27688481 · DOI
  29. [34]Chaudhari AS Prospective deployment of deep learning in MRI: a framework for important considerations, challenges, and recommendations for best practices J. Magn. Reson. Imaging 2021 54 357 371 10.1002/jmri.27331 32830874 PMC8639049 · DOI
  30. [35]Chen, K. T. et al. True ultra-low-dose amyloid PET/MRI enhanced with deep learning for clinical interpretation. Eur. J. Nucl. Med. Mol. Imaging.48, 2416–2425. (2021). PMC8891344 33416955
  31. [37]Gholami S Salavati A Houshmand S Werner TJ Alavi A Assessment of atherosclerosis in large vessel walls: a comprehensive review of FDG-PET/CT image acquisition protocols and methods for uptake quantification J. Nucl. Cardiol. 2015 22 468 479 10.1007/s12350-015-0069-8 25827619 · DOI
  32. [39]Ahlman MA Internal tissue references for 18Fluorodeoxyglucose vascular inflammation imaging: Implications for cardiovascular risk stratification and clinical trials PLoS ONE 2017 12 1 12 10.1371/journal.pone.0187995 PMC5683610 29131857 · DOI
  33. [40]Paldino MJ Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study Pediatr. Radiol. 2017 47 1500 1507 10.1007/s00247-017-3888-8 28512714 · DOI
  34. [41]Nestle U Comparison of different methods for delineation of 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-Small cell lung cancer J. Nucl. Med. 2005 46 1342 1348 16085592

Cited by

Sorted by citations

Authors
Chaudhari, A. S., Mittra, E., Davidzon, G. A., Gulaka, P., Gandhi, H., Brown, A., Zhang, T., Srinivas, S., Gong, E., Zaharchuk, G., & Jadvar, H.
Affiliations
  • Stanford University (US)
  • Oregon Health & Science University (US)
  • University of Pittsburgh Medical Center (US)
  • University of Southern California (US)
Corresponding author
Chaudhari, Akshay S.
Venue
npj Digital Medicine
Published
2021-08-23
Volume
4
Issue
1
Pages
127-127
ISSN
2398-6352 (ISSN-L)
OpenAlex
W3194623075
Cited by
83
References
44
Citations by year
2026: 15 · 2025: 17 · 2024: 16 · 2023: 20 · 2022: 12 · 2021: 3
FWCI
6.74
Type
journal article
Language
en
Open access
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
low-count PET, whole-body PET, deep learning reconstruction, image enhancement, diagnostic quality, SUV quantification, lesion detection, radiation dose reduction, scan time reduction, interobserver agreement, tumor imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review