Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Modifiable Practices Associated with Sudden Death among Hemodialysis Patients in the Dialysis Outcomes and Practice Patterns Study

Open access
Jadoul, Michel, Thumma, Jyothi, Fuller, Douglas S., Tentori, Francesca, Li, Yun, Morgenstern, Hal, Mendelssohn, David, Tomo, Tadashi, Ethier, Jean, Port, Friedrich, Robinson, Bruce M. · 2012 · Clinical Journal of the American Society of Nephrology

Abstract

Summary: Background and objectives: Sudden death is common in hemodialysis patients, but whether modifiable practices affect the risk of sudden death remains unclear. Design, setting, participants, & measurements: This study analyzed 37,765 participants in 12 countries in the Dialysis Outcomes and Practice Patterns Study to explore the association of the following practices with sudden death (due to cardiac arrhythmia, cardiac arrest, and/or hyperkalemia): treatment time [TT] <210 minutes, Kt/V <1.2, ultrafiltration volume >5.7% of postdialysis weight, low dialysate potassium [K D <3]), and prescription of Q wave/T wave interval–prolonging drugs. Cox regression was used to estimate effects on mortality, adjusting for potential confounders. An instrumental variable approach was used to further control for unmeasured patient-level confounding. Results: There were 9046 deaths, 26% of which were sudden (crude mortality rate, 15.3/100 patient-years; median follow-up, 1.59 years). Associations with sudden death included hazard ratios of 1.13 for short TT, 1.15 for large ultrafiltration volume, and 1.10 for low Kt/V. Compared with K D ≥3 mEq/L, the sudden death rate was higher for K D ≤1.5 and K D=2–2.5 mEq/L. The instrumental variable approach yielded generally consistent findings. The sudden death rate was elevated for patients taking amiodarone, but not other Q wave/T wave interval–prolonging drugs. Conclusions: This study identified modifiable dialysis practices associated with higher risk of sudden death, including short TT, large ultrafiltration volume, and low K D. Because K D <3 mEq/L is common and easy to change, K D tailoring may prevent some sudden deaths. This hypothesis merits testing in clinical trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.08850811

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 184

Metadata

Authors
Jadoul, M., Thumma, J., Fuller, D. S., Tentori, F., Li, Y., Morgenstern, H., Mendelssohn, D., Tomo, T., Ethier, J., Port, F., & Robinson, B. M.
Venue
Clinical Journal of the American Society of Nephrology
Published
2012-05
Volume
7
Issue
5
Pages
765-774
ISSN
1555-9041 (ISSN-L)
OpenAlex
W2109241621
Cited by
184
References
8
FWCI
8.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modifiable Practices Associated with Sudden Death among Hemodialysis Patients in the Dialysis Outcomes and Practice Patterns Study. https://app.cochat.ai/papers/10.2215/cjn.08850811
The paper
Jadoul, M., Thumma, J., Fuller, D. S., Tentori, F., Li, Y., Morgenstern, H., Mendelssohn, D., Tomo, T., Ethier, J., Port, F., & Robinson, B. M. (2012). Modifiable Practices Associated with Sudden Death among Hemodialysis Patients in the Dialysis Outcomes and Practice Patterns Study. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.08850811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.