The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Size and Dose on The Biodistribution of Graphene Oxide in Mice
Abstract
AIM: Graphene oxide (GO) has promising applications in bioimaging, diagnostics and therapeutics. This work studied the effects of size and injection dose on the biodistribution of GO to accelerate the development of a GO-based drug. METHODS: GO samples were intravenously injected into mice. The content of GO in organs/tissues at different time points was measured using an (125)I-labeling technique. GO in the liver and lungs was further confirmed by both Raman spectroscopic and TEM observations. The dispersion state of GO in serum was evaluated by flow cytometry. RESULTS: Regardless of size, GO was cleared from the blood quickly and accumulated mainly in the liver and lungs. The uptake of GO in lungs increased with increasing injection dose and size. The dispersion state (i.e., size of the GO-protein complex in blood) dominated the biodistribution. CONCLUSION: The size and dose of GO affected its fate in vivo. For medical applications, small-sized GO with suitable funtionalization is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of dose on the biodistribution and pharmacokinetics of PLGA and PLGA-mPEG nanoparticles
Panagi, Z., Beletsi, A., Evangelatos, G., Livaniou, E., Ithakissios, D. S., & Avgoustakis, K. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00676-7 · Cited by 215
Cited by
Surface functionalized exosomes as targeted drug delivery vehicles for cerebral ischemia therapy
Tian, T., Zhang, H.-X., He, C.-P., Fan, S., Zhu, Y.-L., Qi, C., Huang, N.-P., Xiao, Z.-D., Lu, Z.-H., Tannous, B. A., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.012 · Cited by 1,154
Harnessing the chemistry of graphene oxide
Dreyer, D. R., Todd, A. D., & Bielawski, C. W. (2014) · Chemical Society Reviews · doi:10.1039/c4cs00060a · Cited by 879
Toxicity of graphene-family nanoparticles: a general review of the origins and mechanisms
Ou, L., Song, B., Liang, H., Liu, J., Feng, X., Deng, B., Sun, T., & Shao, L. (2016) · Particle and Fibre Toxicology · doi:10.1186/s12989-016-0168-y · Cited by 803
Self-citationSafety Assessment of Graphene-Based Materials: Focus on Human Health and the Environment
Fadeel, B., Bussy, C., Merino, S., Vázquez, E., Flahaut, E., Mouchet, F., Evariste, L., Gauthier, L., Koivisto, A. J., Vogel, U., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b04758 · Cited by 671
Graphene: Safe or Toxic? The Two Faces of the Medal
Bianco, A. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201209099 · Cited by 557
Metadata
- Authors
- Liu, J.-H., Yang, S.-T., Wang, H., Chang, Y., Cao, A., & Liu, Y.
- Venue
- Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2012-12
- Volume
- 7
- Issue
- 12
- Pages
- 1801-1812
- ISSN
- 1743-5889 (ISSN-L)
- 1748-6963
- OpenAlex
- W2154580307
- Cited by
- 215
- References
- 1
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.