The dorsal skinfold chamber: window into the dynamic interaction of biomaterials with their surrounding host tissue
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The implantation of biomaterials into the human body has become an indispensable part of almost all fields of modern medicine. Accordingly, there is an increasing need for appropriate approaches, which can be used to evaluate the suitability of different biomaterials for distinct clinical indications. The dorsal skinfold chamber is a sophisticated experimental model, which has been proven to be extremely valuable for the systematic in vivo analysis of the dynamic interaction of small biomaterial implants with the surrounding host tissue in rats, hamsters and mice. By means of intravital fluorescence microscopy, this chronic model allows for repeated analyses of various cellular, molecular and microvascular mechanisms, which are involved in the early inflammatory and angiogenic host tissue response to biomaterials during the initial 2-3 weeks after implantation. Therefore, the dorsal skinfold chamber has been broadly used during the last two decades to assess the in vivo performance of prosthetic vascular grafts, metallic implants, surgical meshes, bone substitutes, scaffolds for tissue engineering, as well as for locally or systemically applied drug delivery systems. These studies have contributed to identify basic material properties determining the biocompatibility of the implants and vascular ingrowth into their surface or internal structures. Thus, the dorsal skinfold chamber model does not only provide deep insights into the complex interactions of biomaterials with the surrounding soft tissues of the host but also represents an important tool for the future development of novel biomaterials aiming at an optimisation of their biofunctionality in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“This interaction is a highly dynamic process, which is subsumed under the term ‘foreign body reaction’ and comprises distinct steps (Anderson et al., 2008).”
BackgroundGiannoudis, P. V., Dinopoulos, H., & Tsiridis, E. (2005) · Injury · doi:10.1016/j.injury.2005.07.029 · Cited by 2,078
Fiedler, U., Reiss, Y., Scharpfenecker, M., Grunow, V., Koidl, S., Thurston, G., Gale, N. W., Witzenrath, M., Rosseau, S., Suttorp, N., et al. (2006) · Nature Medicine · doi:10.1038/nm1351 · Cited by 933
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
A review on macrophage responses to biomaterials
Xia, Z., & Triffitt, J. T. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/1/r01 · Cited by 418
Macrophage and dendritic cell phenotypic diversity in the context of biomaterials
Kou, P. M., & Babensee, J. E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32971 · Cited by 190
Role of plasma fibronectin in the foreign body response to biomaterials
Keselowsky, B. G., Bridges, A. W., Burns, K. L., Tate, C. C., Babensee, J. E., LaPlaca, M. C., & García, A. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.035 · Cited by 130
Cited by
Roland, L., Grau, M., Matena, J., Teske, M., Gieseke, M., Kampmann, A., Beyerbach, M., Murua Escobar, H., Haferkamp, H., Gellrich, N.-C., et al. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms17010001 · Cited by 862
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Bioactive Glasses: Sprouting Angiogenesis in Tissue Engineering
Kargozar, S., Baino, F., Hamzehlou, S., Hill, R. G., & Mozafari, M. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.12.003 · Cited by 349
Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137301 · Cited by 124
Improvement of islet transplantation by the fusion of islet cells with functional blood vessels
Nalbach, L., Roma, L. P., Schmitt, B. M., Becker, V., Körbel, C., Wrublewsky, S., Pack, M., Später, T., Metzger, W., Menger, M. M., et al. (2021) · EMBO Molecular Medicine · doi:10.15252/emmm.202012616 · Cited by 106
Self-citationInjectable Therapeutic Organoids Using Sacrificial Hydrogels
Rossen, N. S., Anandakumaran, P. N., zur Nieden, R., Lo, K., Luo, W., Park, C., Huyan, C., Fu, Q., Song, Z., Singh-Moon, R. P., et al. (2020) · iScience · doi:10.1016/j.isci.2020.101052 · Cited by 36
Ampofo, E., Berg, J. J., Menger, M. D., & Laschke, M. W. (2019) · Scientific Reports · doi:10.1038/s41598-019-42465-7 · Cited by 27
Self-citation
Metadata
- Authors
- Institute for Clinical and Experimental Surgery, U. O. S., Laschke, M., Vollmar, & Menger, M.
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2011-09-20
- Volume
- 22
- Pages
- 147-167
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W182566489
- Cited by
- 155
- References
- 8
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.