Atrial Fibrillation Detection Using Photo:plethysmography and Acceleration Data at the Wrist
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Atrial fibrillation (AF) is a pathological cardiac condition leading to increased risk for embolic stroke.Screening for AF is challenging due to the paroxysmal and asymptomatic nature of the condition.We aimed to investigate whether an unobtrusive wrist-wearable device equipped with a photo-plethysmographic (PPG) and acceleration sensor could detect AF.Sixteen patients with suspected AF were monitored for 24 hours in an outpatient setting using a Holter ECG.Simultaneously, PPG and acceleration data were collected at the wrist.PPG data was processed to determine the timing of heartbeats and inter-beat-interval (IBI).Wrist acceleration and PPG morphology were used to discard IBIs in presence of motion artefacts.An ECG validated first-order Markov model was used to assess the probability of irregular rhythm due to AF using PPG-derived IBIs.The AF detection algorithm was compared with clinical adjudications of AF episodes after review of the ECG records.AF detection was achieved with 97 ± 2% sensitivity and 99 ± 3% specificity.Due to motion artefacts, the algorithm did not provide AF classification for an average of 36 ± 9% of the 24 hours monitoring.We concluded that a wrist-wearable device equipped with a PPG and acceleration sensor can accurately detect rhythm irregularities caused by AF in daily life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506 · cited 1×
“AF is a growing issue in our ageing society since the prevalence of AF steeply increases with age and it affects more than 10% of individuals aged >75 years [1].”
BackgroundMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Optical heart rate monitoring module validation study
Valenti, G., & Westerterp, K. R. (2013) · 2013 IEEE International Conference on Consumer Electronics (ICCE) · doi:10.1109/icce.2013.6486856 · Cited by 32 · cited 1×
“Validation of this PPG and accelerometer system to measure heart rate during different free-living conditions was provided in previous publications [7, 8].”
Method
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
“The most common approach to deal with this issue is to simply discard the corrupted segments and use only the clean parts of PPG signals.(49,50,58,60,64,74) Some of the works followed a two-step approach: first, to identify motion artifacts by using accelerometer data, or by performing PPG signal quality assessment; a…”
BackgroundMethodHeart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simoes-Capela, N., Van Hoof, C., & Van Helleputte, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 258
Sartor, F., Gelissen, J., van Dinther, R., Roovers, D., Papini, G. B., & Coppola, G. (2018) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-018-0098-0 · Cited by 65
Eerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M., & Aarts, R. M. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad2c0 · Cited by 61
Self-citationContinuous heart rhythm monitoring using mobile photoplethysmography in ambulatory patients
Hochstadt, A., Havakuk, O., Chorin, E., Schwartz, A. L., Merdler, I., Laufer, M., Lubman, N., Ghantous, E., Viskin, S., & Rosso, R. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.04.017 · Cited by 18
Metadata
- Authors
- Bonomi, A., Schipper, F., Eerikainen, L., Margarito, J., Aarts, R., Babaeizadeh, S., de Morree, H., & Dekker, L.
- Venue
- 2016 Computing in Cardiology Conference (CinC)
- Publisher
- Computing in Cardiology
- Published
- 2016-09-14
- Volume
- 43
- ISSN
- 2325-887X (ISSN-L)
- OpenAlex
- W2594117425
- Cited by
- 57
- References
- 3
- FWCI
- 15.96
- Type
- conference paper
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial Fibrillation Detection Using Photo:plethysmography and Acceleration Data at the Wrist. https://app.cochat.ai/papers/10.22489/cinc.2016.081-339
- The paper
- Bonomi, A., Schipper, F., Eerikainen, L., Margarito, J., Aarts, R., Babaeizadeh, S., de Morree, H., & Dekker, L. (2016). Atrial Fibrillation Detection Using Photo:plethysmography and Acceleration Data at the Wrist. 2016 Computing in Cardiology Conference (CinC). https://doi.org/10.22489/cinc.2016.081-339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.