Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
Open accessAbstract
BACKGROUND: The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients. METHODS: One hundred ninety-nine healthy volunteers, 84 males and 115 females, including 35 overweight-obese subjects, 53 pregnant women, and 20 CAD patients were tested in the present study. Second-by-second HR measured by the OHRM was concurrently evaluated against an ECG-based chest strap monitor during a broad range of activities (i.e., walking, running, cycling, gym, household, and sedentary activities). RESULTS: Data coverage, percentage of time the OHRM provides a HR not larger than 10 bpm from the reference, went from a minimum of 92% of the time in the least periodic activity (i.e., gym), to 95% during the most intense activity (i.e., running), and to a maximum of 98% for sedentary activities. The limits of agreement of the difference between the OHRM and the chest strap HR were within the range of ±15 bpm. The OHRM showed a concordance correlation coefficient of 0.98. Overall, the mean absolute error was not larger than 3 bpm, which can be considered clinically acceptable for a number of applications. A similar performance was found for CAD (94.2% coverage, 2.4 bpm error), but the small sample size does not allow any quantitative comparison. CONCLUSION: Heart rate measured by OHRM at the wrist and ECG-based HR measured via a traditional chest strap are acceptably close in a broad range of activities in a heterogeneous, healthy population, and showed initial promising results also in CAD patients.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cyclical motion can affect the accuracy of heart rate in wearable sensors.
“Several research groups and manufacturers have identified that cyclical motion can affect accuracy of HR in wearable sensors.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Authors/Task Force Members:, Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, M., Albus, C., Benlian, P., Boysen, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs092 · Cited by 8,490 · see citing works
2016 European Guidelines on cardiovascular disease prevention in clinical practice
Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M.-T., Corrà, U., Cosyns, B., Deaton, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw106 · Cited by 6,457 · see citing works
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
2016 European Guidelines on cardiovascular disease prevention in clinical practice
Authors/Task Force Members, Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M. T., Corrà, U., Cosyns, B., et al. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316653709 · Cited by 1,409 · see citing works
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,202 · see citing works
Keith, A., & Flack, M. (1907) · Europe PMC (PubMed Central) · Cited by 616 · see citing works
ACSM's resource manual for Guidelines for exercise testing and prescription
Kaminsky, L. A. (2006) · Acquire (CQUniversity) · Cited by 607 · see citing works
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 566 · see citing works
The regulation of the heart beat
Patterson, S. W., Piper, H., & Starling, E. H. (1914) · The Journal of Physiology · doi:10.1113/jphysiol.1914.sp001676 · Cited by 549 · see citing works
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Weippert, M., Kumar, M., Kreuzfeld, S., Arndt, D., Rieger, A., & Stoll, R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1415-9 · Cited by 302 · see citing works
(2002) · QUT ePrints (Queensland University of Technology) · Cited by 282 · see citing works
Kingsley, M., Lewis, M. J., & Marson, R. E. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-817878 · Cited by 230 · see citing works
Heart rate monitors: State of the art
Laukkanen, R. M. T., & Virtanen, P. K. (1998) · Journal of Sports Sciences · doi:10.1080/026404198366920 · Cited by 219 · see citing works
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203 · see citing works
Interaction of Cardiovascular Reflexes in Circulatory Control
Abboud, F. M., & Thames, M. D. (1983) · Comprehensive physiology · doi:10.1002/cphy.cp020319 · Cited by 191 · see citing works
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148 · see citing works
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139 · see citing works
Sartor, F., Vernillo, G., de Morree, H. M., Bonomi, A. G., Torre, A. L., Kubis, H., & Veicsteinas, A. (2013) · Sports Medicine · doi:10.1007/s40279-013-0068-3 · Cited by 136 · see citing works
Self-citationAccuracy of smartphone apps for heart rate measurement
Coppetti, T., Brauchlin, A. E., Müggler, S. A., Attinger‐Toller, A., Templin, C., Schoenrath, F., Hellermann, J. P., Lüscher, T. F., Biaggi, P., & Wyss, C. A. (2017) · European Journal of Preventive Cardiology · doi:10.1177/2047487317702044 · Cited by 130 · see citing works
Exercise Guidelines in Pregnancy
Zavorsky, G. S., & Longo, L. D. (2011) · Sports Medicine · doi:10.2165/11583930-000000000-00000 · Cited by 127 · see citing works
Kroll, R. R., Boyd, J. G., & Maslove, D. M. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.6025 · Cited by 123 · see citing works
ACSM's resource manual for guidelines for exercise testing and prescription
Ehrman, J. K. (2010) · Lippincott Williams & Wilkins eBooks · Cited by 120 · see citing works
Han, H., & Kim, J. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.12.005 · Cited by 92 · see citing works
The Accuracy of Heart Rate Monitoring by Some Wrist-Worn Activity Trackers
Cadmus‐Bertram, L., Gangnon, R. E., Wirkus, E. J., Thraen-Borowski, K. M., & Gorzelitz, J. (2017) · Annals of Internal Medicine · doi:10.7326/l16-0353 · Cited by 80 · see citing works
Wearable, yes, but able…?: it is time for evidence-based marketing claims!
Sperlich, B., & Holmberg, H. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-097295 · Cited by 76 · see citing works
Recent Advances in Free-Living Physical Activity Monitoring: A Review
André, D., & Wolf, D. L. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100522 · Cited by 72 · see citing works
Reduction of Periodic Motion Artifacts in Photoplethysmography
Wijshoff, R. W. C. G. R., Mischi, M., & Aarts, R. M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2553060 · Cited by 65 · see citing works
Atrial Fibrillation Detection Using Photo:plethysmography and Acceleration Data at the Wrist
Bonomi, A., Schipper, F., Eerikäinen, L. M., Margarito, J., Aarts, R. M., Babaeizadeh, S., de Morree, H. M., & Dekker, L. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.081-339 · Cited by 60 · see citing works
Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device
Delgado-Gonzalo, R., Parák, J., Tarniceriu, A., Renevey, P., Bertschi, M., & Korhonen, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318391 · Cited by 55 · see citing works
Accuracy of heart rate assessment in atrial fibrillation.
Sneed, N. V., & Hollerbach, A. D. (1992) · PubMed · Cited by 38 · see citing works
Optical heart rate monitoring module validation study
Valenti, G., & Westerterp, K. R. (2013) · 2013 IEEE International Conference on Consumer Electronics (ICCE) · doi:10.1109/icce.2013.6486856 · Cited by 32 · see citing works
Evaluation of the Canadian Home Fitness Test in middle-aged men.
Cumming, G. R., & Glenn, J. (1977) · PubMed Central · Cited by 14 · see citing works
Holter, N. J. (1998) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1998.tb00046.x · Cited by 14 · see citing works
Training centres in physical medicine.
Albi, W. N. (1977) · PubMed Central · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350 · see citing works
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
“Several research groups and manufacturers have identified that cyclical motion can affect accuracy of HR in wearable sensors.(9,10,15) The cyclical motion challenge has been described as a “signal crossover” effect wherein the optical HR sensors on wearables tend to lock on to the periodic signal stemming from the”
BackgroundTissue adhesive hydrogel bioelectronics
Li, S., Cong, Y., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb00523e · Cited by 260 · see citing works
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140 · see citing works
“These include the MAPE test, the Bland-Altman analysis, the correlation PPMCC, ICC, and CCC tests [2,12,13,15,53].”
Li, X., Zeng, X., Xia, F., Jin, W., Liu, Y., & Hu, Y. (2020) · ACS Nano · doi:10.1021/acsnano.0c01164 · Cited by 139 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116 · see citing works
Remotely monitored telerehabilitation for cardiac patients: A review of the current situation
Baťalík, L., Filáková, K., Batalikova, K., & Dosbaba, F. (2020) · World Journal of Clinical Cases · doi:10.12998/wjcc.v8.i10.1818 · Cited by 111 · see citing works
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Al‐Qatatsheh, A., Morsi, Y., Zavabeti, A., Zolfagharian, A., Salim, N., Kouzani, A., Mosadegh, B., & Gharaie, S. (2020) · Italian National Conference on Sensors · doi:10.3390/s20164484 · Cited by 48 · see citing works
Patel, V., Orchanian‐Cheff, A., & Wu, R. C. (2021) · JMIR mhealth and uhealth · doi:10.2196/17411 · Cited by 65 · see citing works
Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data
Eerikäinen, L. M., Bonomi, A., Schipper, F., Dekker, L., de Morree, H. M., Vullings, R., & Aarts, R. M. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2950574 · Cited by 61 · see citing works
Müller, A. M., Wang, N. X., Yao, J., Tan, C. S., Low, I. C. C., Lim, N., Tan, J., Tan, A. W. H., & Müller‐Riemenschneider, F. (2019) · JMIR mhealth and uhealth · doi:10.2196/14120 · Cited by 59 · see citing works
Wearable technology for early detection of COVID-19: A systematic scoping review
Cheong, S. H. R., Ng, Y. J. X., Lau, Y., & Lau, S. T. (2022) · Preventive Medicine · doi:10.1016/j.ypmed.2022.107170 · Cited by 49 · see citing works
Reddy, G. N. K., Manikandan, M. S., Murty, N. V. L. N., & Cenkeramaddi, L. R. (2023) · IEEE Access · doi:10.1109/access.2023.3269584 · Cited by 32 · see citing works
Accuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Hermand, É., Coll, C., Richalet, J., & Lhuissier, F. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1337-2790 · Cited by 31 · see citing works
A computationally efficient algorithm for wearable sleep staging in clinical populations
Fonseca, P. M., Ross, M., Cerny, A., Anderer, P., van Meulen, F., Janssen, H. C. J. P., Pijpers, A., Dujardin, S., van Hirtum, P. V., van Gilst, M. M., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-36444-2 · Cited by 27 · see citing works
Wallace, T. D., Morris, J., Glickstein, R., Anderson, R. K., & Gore, R. K. (2022) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0000000000000774 · Cited by 24 · see citing works
Skin tone, confidence, and data quality of heart rate sensing in WearOS smartwatches
Ray, I., Liaqat, D., Gabel, M., & de Lara, E. (2021) · 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9431120 · Cited by 23 · see citing works
HRS White Paper on Clinical Utilization of Digital Health Technology
Wan, E. Y., Ghanbari, H., AKOUM, N. W., Attia, Z. I., Asirvatham, S. J., Chung, E. H., Dagher, L., Al‐Khatib, S. M., Mendenhall, G. S., McManus, D. D., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.07.001 · Cited by 21 · see citing works
Climstein, M., Alder, J. L., Brooker, A. M., Cartwright, E. J., Kemp‐Smith, K., Simas, V., & Furness, J. W. (2020) · Sports · doi:10.3390/sports8090117 · Cited by 20 · see citing works
Use of a non-human robot audience to induce stress reactivity in human participants
Turner‐Cobb, J. M., Asif, M., Turner, J. E., Bevan, C., & Fraser, D. S. (2019) · Computers in Human Behavior · doi:10.1016/j.chb.2019.05.019 · Cited by 20 · see citing works
Andrikopoulou, E. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15980-0.00011-9 · Cited by 18 · see citing works
Ibrahim, N. S., Rampal, S., Lee, W. L., Pek, E. W., & Suhaimi, A. (2023) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-023-00693-z · Cited by 16 · see citing works
Neudorfer, M., Kumar, D., Smeddinck, J. D., Kulnik, S. T., Niebauer, J., Treff, G., & Sareban, M. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14756 · Cited by 15 · see citing works
DiPasquale, J., Trammell, M., Clark, K., Fowler, H., Callender, L., Bennett, M., & Swank, C. (2021) · PM&R · doi:10.1002/pmrj.12577 · Cited by 16 · see citing works
Kinetic liquid metal synthesis of flexible 2D conductive oxides for multimodal wearable sensing
Rahman, M. S., Agnew, S. A., Ong, S. W., & Scheideler, W. J. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00371-7 · Cited by 15 · see citing works
A Comparative Study between ECG-based and PPG-based Heart Rate Monitors for Stress Detection
Pinge, A., Bandyopadhyay, S., Ghosh, S., & Sen, S. (2022) · International Conference on Communication Systems & Networks (COMSNETS) · doi:10.1109/comsnets53615.2022.9668342 · Cited by 15 · see citing works
Samyoun, S., Islam, M. M., Iqbal, T., & Stankovic, J. A. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3534600 · Cited by 14 · see citing works
Multi-night home assessment of sleep structure in OSA with and without insomnia
Wulterkens, B. M., Teuling, N. D., Hermans, L. W., Asin, J., Duis, N., Overeem, S., Fonseca, P. M., & van Gilst, M. M. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.03.031 · Cited by 13 · see citing works
SensorHub: Multimodal Sensing in Real-Life Enables Home-Based Studies
Chromik, J., Kirsten, K., Herdick, A., Kappattanavar, A. M., & Bert Arnrich, A. (2022) · Sensors · doi:10.3390/s22010408 · Cited by 13 · see citing works
Sosa‐Hernandez, L., Vogel, N., Frankiewicz, K., Reaume, C. L., Drew, A., Neufeld, S. M., & Thomassin, K. (2024) · Psychophysiology · doi:10.1111/psyp.14699 · Cited by 13 · see citing works
Chen, C.-C., Chen, Y., Tang, L., & Chieng, W.-H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19084810 · Cited by 13 · see citing works
Reddy, G. N. K., Manikandan, M. S., & Murty, N. V. L. N. (2021) · IEEE International Conference on Health, Instrumentation & Measurement, and Natural Sciences (InHeNce) · doi:10.1109/inhence52833.2021.9537236 · Cited by 11 · see citing works
Marzano‐Felisatti, J. M., Lucca, L. D., Priego‐Quesada, J. I., & Pino‐Ortega, J. (2024) · Applied Sciences · doi:10.3390/app142411872 · Cited by 9 · see citing works
Students Activity Recognition by Heart Rate Monitoring in Classroom using K-Means Classification
Zuraini, H. H. M., Ismail, W., Hendradi, R., & Justitia, A. (2020) · Journal of Information Systems Engineering and Business Intelligence · doi:10.20473/jisebi.6.1.46-54 · Cited by 9 · see citing works
A two-phased study on the use of remote photoplethysmography (rPPG) in paediatric care
Hatib, N. A. A., Lee, J. H., Chong, S., Sng, Q. W., Tan, V. S. R., Ong, G. Y.-K., Lim, A. M., Quek, B. H., How, M. S., Chan, J. M. F., et al. (2024) · Annals of Translational Medicine · doi:10.21037/atm-23-1896 · Cited by 7 · see citing works
Sivaranjini, P. N., & Manikandan, M. S. (2023) · International Conference on Bio-engineering for Smart Technologies (BioSMART) · doi:10.1109/biosmart58455.2023.10162081 · Cited by 7 · see citing works
Jørgensen, A., Toftager, M., Eghøj, M., Ried‐Larsen, M., & Petersen, C. B. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1213655 · Cited by 5 · see citing works
Vermunicht, P., Makayed, K., Buyck, C., Knaepen, L., Giraldo, J. S. P., Naessens, S., Hens, W., Craenenbroeck, E. M. V., Laukens, K., Desteghe, L., et al. (2025) · Digital Health · doi:10.1177/20552076251337598 · Cited by 5 · see citing works
van der Aar, J. F., van Gilst, M. M., van den Ende, D., van Gorp, H., Anderer, P., Pijpers, A., Fonseca, P. M., Peri, E., & Overeem, S. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70046 · Cited by 5 · see citing works
Sivaranjini, P. N., Manikandan, M. S., & Cenkeramaddi, L. R. (2023) · International Conference on Electronics, Computers and Artificial Intelligence (ECAI) · doi:10.1109/ecai58194.2023.10194196 · Cited by 6 · see citing works
Wrist-Worn Devices for Remote Monitoring of Cardiovascular Disease: A Survey
Sadiq, I., Ijaz, A., & Imran, A. (2025) · IEEE Access · doi:10.1109/access.2025.3602893 · Cited by 6 · see citing works
Bester, M., Moors, S., Joshi, R., Nichting, T. J., der Jagt, M. B. V. D. H., Oei, S. G., Mischi, M., Vullings, R., & van Laar, J. O. E. H. (2021) · Clinics and Practice · doi:10.3390/clinpract11010004 · Cited by 4 · see citing works
SPORCULARIN KALP ATIM HIZININ ESP-NOW KULLANILARAK KABLOSUZ İLETİMİ
DÜNDAR, Ö. M., & Aydın, A. (2021) · Konya Journal of Engineering Sciences · doi:10.36306/konjes.879392 · Cited by 3 · see citing works
Stangl, F. J., & Riedl, R. (2024) · Springer eBooks · doi:10.1007/978-3-658-46113-3_15 · Cited by 3 · see citing works
Batteryless NFC Device for Heart Rate and SpO2 Acquisition
Bispo, B. C., Cunha, N. A., Silva, M. B. C., & Rodrigues, M. A. B. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49407-9_47 · Cited by 2 · see citing works
Guerrero-Blázquez, A., Álvarez-Melcón, Á. C., López-Marcos, J. J., Martín‐Casas, P., Escudero, A. A., & Ortiz-Gutiérrez, R. M. (2026) · Sensors · doi:10.3390/s26030828 · Cited by 1 · see citing works
Effectiveness of smart wrist wearables for distinguishing physical and cognitive demands
Cha, J. S., Ausri, F., Mudge, L., & Yu, D. (2022) · IISE Transactions on Healthcare Systems Engineering · doi:10.1080/24725579.2022.2142867 · Cited by 1 · see citing works
Specific Cardiovascular Diseases and Competitive Sports Participation: Pacemakers and ICD
Miljoen, H., Lampert, R. J., & Heidbüchel, H. (2020) · Springer eBooks · doi:10.1007/978-3-030-35374-2_18
Effect of Skin Tone on the Confidence of WearOS Smartwatches
Ray, I. (2020) · TSpace (University of Toronto)
Investigating Sources of Inaccuracy in Wearable Optical Heart Rate Sensors (Preprint)Preprint
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. (2020) · doi:10.2196/preprints.18126
Home-based bench step exercise program with Smart Step Board: a comparative pilot study
Kundakcı, Y. E., Taşkın, G., Horata, E. T., & Koz, M. (2023) · Turkish Journal of Sports Medicine · doi:10.47447/tjsm.0727
Lehet, D. (2023) · Acta Polytechnica CTU Proceedings · doi:10.14311/app.2023.41.0020
Neudorfer, M., Ötzlinger, L., Kumar, D., Niebauer, J., Smeddinck, J. D., Sareban, M., & Treff, G. (2025) · Sensors · doi:10.3390/s25185649
Gahtan, B., Vedula, S., Samuelly‐Leichtag, G., Kodesh, E., & Bronstein, A. M. (2025) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/3716553.3750815
Wearable Technologies for Cancer Therapy and Monitoring: A Comprehensive Review
Bera, R., Chauhan, S. B., & Singh, I. (2025) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2025059902
Heart Rate Monitoring Using Continuous-Wave Radar in Home Environment
Chityat, I., Gao, M., Zhang, X., Copeland, D., Mori, B., Okitsu, M., & Anthony, B. (2026) · IEEE Internet of Things Journal · doi:10.1109/jiot.2026.3660570
Agrawal, R., Delen, D., & Benjamin, B. (2026) · Sensors · doi:10.3390/s26123687
Vermunicht, P., Buyck, C., Naessens, S., Hens, W., Craenenbroeck, E. M. V., Laukens, K., Desteghe, L., & Heidbüchel, H. (2026) · JMIR mhealth and uhealth · doi:10.2196/79995
- Authors
- Sartor, F., Gelissen, J., van Dinther, R., Roovers, D., Papini, G. B., & Coppola, G.
- Affiliations
- Philips (Netherlands) (NL)
- Corresponding author
- Sartor, Francesco
- Venue
- BMC Sports Science, Medicine and Rehabilitation
- Published
- 2018-05-31
- Volume
- 10
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2052-1847 (ISSN-L)
- PMC
- PMC5984393
- OpenAlex
- W2805787563
- Cited by
- 65
- References
- 38
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 9 · 2023: 10 · 2022: 7 · 2021: 11 · 2020: 11 · 2019: 6
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Sports Science Medicine and Rehabilitation (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- TU/e Research Portal (submittedVersion, other-oa)
- Funders
- Philips
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart rate monitoring, coronary artery disease, measurement agreement, physical activity, sedentary behavior, pregnant women, wearable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review