Imaging Photoplethysmography: What are the Best Locations on the Face to Estimate Heart Rate?
Open accessAbstract
The potential of imaging photoplethysmography for cardiovascular monitoring applications has been demonstrated recently.Various processing schemes have been proposed to extract heart rate (HR) from a defined region of interest (ROI) on the face.However, the reasons that motivate the choice of the ROI are often unclear.This study aimed at investigating the spatial distribution of the HR-related information on the subject face, based on a partition into 260 small ROIs.A power spectral density (PSD) analysis was performed to determine the amount of HR-related information in each ROI.Normalized color maps were used to visualize the spatial distribution of the HR-information and clearly showed that color fluctuations due to blood volume changes are always more pronounced in the forehead region.After face segmentation, for the R/G/B/NIR channels, average percentages of power of 27%/43%/27%/36% for the forehead region, 17%/28%/18%/21% for the cheek region and 16%/24%/16%/20% for the whole face were obtained.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For all wavelengths of light, the forehead is superior to the cheeks and the whole face for determining heart rate.
“Fallet et al. found via iPPG that for all wavelengths of light, the forehead is superior to the cheeks and the whole face for determining heart rate.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [146]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728 · see citing works
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M., McDuff, D., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,488 · see citing works
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420 · see citing works
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287 · see citing works
Signal recovery in imaging photoplethysmography
Holton, B. D., Mannapperuma, K., Lesniewski, P. J., & Thomas, J. C. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/11/1499 · Cited by 73 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
- Authors
- Fallet, S., Moser, V., Braun, F., & Vesin, J.-M.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Swiss Center for Electronics and Microtechnology (Switzerland) (CH)
- ORCID
- Braun, Fabian
- Venue
- 2016 Computing in Cardiology Conference (CinC)
- Publisher
- Computing in Cardiology
- Published
- 2016-09-14
- Volume
- 43
- ISSN
- 2325-887X (ISSN-L)
- OpenAlex
- W2575479824
- Cited by
- 28
- References
- 5
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 4 · 2018: 3 · 2017: 2
- FWCI
- 6.01
- Type
- conference paper
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Computing in cardiology (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Signal Processing › Biometric Identification and Security
- Keywords
- imaging photoplethysmography, heart rate estimation, face, region of interest selection, power spectral density, frons, blood volume changes, face segmentation, color maps
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review