Cellular Imaging of Inflammation in Atherosclerosis Using Magnetofluorescent Nanomaterials
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: Magnetofluorescent nanoparticles (MFNPs) offer the ability to image cellular inflammation in vivo. To better understand their cellular targeting and imaging capabilities in atherosclerosis, we investigated prototypical dextran-coated near-infrared fluorescent MFNPs in the apolipoprotein E-deficient (apo E−/−) mouse model. Methods and Results: In vitro MFNP uptake was highest in activated murine macrophages ( p < .001). Apo E−/− mice ( n = 11) were next injected with the MFNP (15 mg/kg iron) or saline. In vivo magnetic resonance imaging (MRI) demonstrated strong plaque enhancement by the MFNPs ( p < .001 vs. saline), which was confirmed by multimodality ex vivo MRI and fluorescence reflectance imaging. On fluorescence microscopy, MFNPs were found in cellular-rich areas of atheroma and colocalized with immunofluorescent macrophages over endothelial cells and smooth muscle cells ( p < .001). Conclusions: Here we show that (1) the in vitro and in vivo cellular distribution of atherosclerosis-targeted MFNPs can be quantified by using fluorescence imaging methods; (2) in atherosclerosis, dextranated MFNPs preferentially target macrophages; and (3) MFNP deposition in murine atheroma can be noninvasively detected by in vivo MRI. This study thus provides a foundation for using MFNPs to image genetic and/or pharmacological perturbations of cellular inflammation in experimental atherosclerosis and for the future development of novel targeted nanomaterials for atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammation in atherosclerosis
Libby, P. (2002) · Nature · doi:10.1038/nature01323 · Cited by 8,315
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798 · cited 1×
“These nanoparticle uptake findings are consistent with prior in vitro endothelial cell data [34] and with in vivo data on human atheroma [12].”
Result
Cited by
Theranostics: Combining Imaging and Therapy
Kelkar, S. S., & Reineke, T. M. (2011) · Bioconjugate Chemistry · doi:10.1021/bc200151q · Cited by 1,385
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Self-citationImaging macrophages with nanoparticles
Weissleder, R., Nahrendorf, M., & Pittet, M. J. (2014) · Nature Materials · doi:10.1038/nmat3780 · Cited by 809
Aikawa, E., Nahrendorf, M., Figueiredo, J.-L., Swirski, F. K., Shtatland, T., Kohler, R. H., Jaffer, F. A., Aikawa, M., & Weissleder, R. (2007) · Circulation · doi:10.1161/circulationaha.107.732867 · Cited by 698
Self-citation
Metadata
- Authors
- Jaffer, F. A., Nahrendorf, M., Sosnovik, D., Kelly, K. A., Aikawa, E., & Weissleder, R.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2006-04-01
- Volume
- 5
- Issue
- 2
- Pages
- 85-92
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2186448008
- Cited by
- 149
- References
- 3
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.