CoChat

Dynamic Analysis of the Blood-Brain Barrier Disruption in Experimental Stroke Using Time Domain in Vivo Fluorescence Imaging

Open access
Abulrob, Abedelnasser, Brunette, Eric, Slinn, Jacqueline, Baumann, Ewa, Stanimirovic, Danica · 2008 · Molecular Imaging
Cited by 56

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The blood-brain barrier (BBB) disruption following cerebral ischemia can be exploited to deliver imaging agents and therapeutics into the brain. The aim of this study was (a) to establish novel in vivo optical imaging methods for longitudinal assessment of the BBB disruption and (b) to assess size selectivity and temporal patterns of the BBB disruption after a transient focal ischemia. The BBB permeability was assessed using in vivo time domain near-infrared optical imaging after contrast enhancement with either free Cy5.5 (1 kDa) or Cy5.5 conjugated with bovine serum albumin (BSA) (67 kDa) in mice subjected to either 60- or 20-minute transient middle cerebral artery occlusion (MCAO) and various times of reperfusion (up to 14 days). In vivo imaging observations were corroborated by ex vivo brain imaging and microscopic analyses of fluorescent tracer extravasation. The in vivo optical contrast enhancement with Cy5.5 was spatially larger than that observed with BSA-Cy5.5. Longitudinal studies after a transient 20-minute MCAO suggested a bilateral BBB disruption, more pronounced in the ipsilateral hemisphere, peaking at day 7 and resolving at day 14 after ischemia. The area differential between the BBB disruption for small and large molecules could potentially be useful as a surrogate imaging marker for assessing perinfarct tissues to which neuroprotective therapies of appropriate sizes could be delivered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2310/7290.2008.00025

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 56

Metadata

Authors
Abulrob, A., Brunette, E., Slinn, J., Baumann, E., & Stanimirovic, D.
Venue
Molecular Imaging
Published
2008-11-01
Volume
7
Issue
6
Pages
248-62
ISSN
  • 1535-3508 (ISSN-L)
  • 1536-0121
OpenAlex
W2186803038
Cited by
56
References
1
FWCI
3.56
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Analysis of the Blood-Brain Barrier Disruption in Experimental Stroke Using Time Domain in Vivo Fluorescence Imaging. https://app.cochat.ai/papers/10.2310/7290.2008.00025
The paper
Abulrob, A., Brunette, E., Slinn, J., Baumann, E., & Stanimirovic, D. (2008). Dynamic Analysis of the Blood-Brain Barrier Disruption in Experimental Stroke Using Time Domain in Vivo Fluorescence Imaging. Molecular Imaging. https://doi.org/10.2310/7290.2008.00025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.