Diurnal Pattern of Insulin Action in Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index; 5 of the 25 sources its claims cite were checked for support.
Abstract
We recently demonstrated a diurnal pattern to insulin action (i.e., insulin sensitivity [SI]) in healthy individuals with higher SI at breakfast than at dinner. To determine whether such a pattern exists in type 1 diabetes, we studied 19 subjects with C-peptide–negative diabetes (HbA1c 7.1 ± 0.6%) on insulin pump therapy with normal gastric emptying. Identical mixed meals were ingested during breakfast, lunch, and dinner at 0700, 1300, and 1900 h in randomized Latin square of order on 3 consecutive days when measured daily physical activity was equal. The triple tracer technique enabled measurement of glucose fluxes. Insulin was administered according to the customary insulin:carbohydrate ratio for each participant. Although postprandial glucose excursions did not differ among meals, insulin concentration was higher (P < 0.01) and endogenous glucose production less suppressed (P < 0.049) at breakfast than at lunch. There were no differences in meal glucose appearance or in glucose disappearance between meals. Although there was no statistical difference (P = 0.34) in SI between meals in type 1 diabetic subjects, the diurnal pattern of SI taken across the three meals in its entirety differed (P = 0.016) from that of healthy subjects. Although the pattern in healthy subjects showed decreasing SI between breakfast and lunch, the reverse SI pattern was observed in type 1 diabetic subjects. The results suggest that in contrast to healthy subjects, SI diurnal pattern in type 1 diabetes is specific to the individual and cannot be extrapolated to the type 1 diabetic population as a whole, implying that artificial pancreas algorithms may need to be personalized.
Overview
CoChat Summary
TL;DR
In 19 adults with C-peptide–negative type 1 diabetes on insulin pump therapy, postprandial glucose excursions did not differ across identical breakfast, lunch, and dinner meals, but insulin concentration was higher and endogenous glucose production less suppressed at breakfast than at lunch. Although insulin sensitivity (SI) did not differ statistically among meals within the type 1 diabetes group, the diurnal SI pattern across meals differed from healthy subjects, suggesting SI patterns in type 1 diabetes are individual-specific and artificial pancreas algorithms may need personalization.
Key findings
- Postprandial glucose excursions did not differ among meals (iAUC P = 0.15), but insulin iAUC was higher at breakfast than lunch (P = 0.008; breakfast vs. lunch P < 0.01), and EGP iAUC was lower at breakfast than lunch (P = 0.049), indicating less EGP suppression at breakfast despite higher insulin.
- SI did not differ among the three meals in type 1 diabetes (P = 0.34), but the diurnal SI pattern across meals differed from healthy subjects (P = 0.016); SI at breakfast was lower in type 1 diabetes than in healthy subjects (5.1 vs. 11.2 × 10−4 dL/kg/min per μU/mL, P = 0.013).
- Estimated mean SI profiles were 5.1–7.6–7.2 × 10−4 dL/kg/min per μU/mL for breakfast, lunch, and dinner in type 1 diabetes, versus 11.2–7.9–8.1 in healthy subjects.
- Meal glucose appearance and glucose disappearance did not differ among meals; glucagon iAUC was higher at breakfast than at lunch or dinner (P < 0.01). Exploratory cortisol, CBG, and melatonin levels did not differ by diabetes status or explain SI differences.
Methods
- Nineteen subjects with C-peptide–negative type 1 diabetes (HbA1c 7.1 ± 0.6%) on insulin pump therapy with normal gastric emptying ingested identical mixed meals at 0700, 1300, and 1900 h on 3 consecutive days, with meal labeling randomized by Latin square and physical activity controlled.
- The triple tracer technique ([6,6-2H2] glucose, [1-13C] glucose-labeled meal, [6-3H] glucose) measured postprandial glucose fluxes; the oral glucose minimal model estimated SI.
- Statistical analysis used SAS PROC MIXED for a three-treatment, three-period crossover design, with a meal-by-diabetes-status interaction comparing type 1 diabetes with healthy subjects.
Limitations
- Stated: the highly structured protocol restricts generalizability; the original sample size anticipated an SD for ln SI of 0.36 and a difference of 0.6 between meals, but observed SDs were 0.89, 0.59, and 1.04 for breakfast, lunch, and dinner, reducing a priori power and increasing type II error risk; larger samples could have shown differences in EGP or SI.
- Stated: the hormone analysis was exploratory and unplanned, using stored samples from only 15 type 1 diabetic and 14 healthy subjects.
- Evident from the text: the study enrolled only 19 type 1 diabetic subjects, and the statistical test for carryover for insulin iAUC had P = 0.04, though no adjustment was implemented per Senn.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
4 Valid · 1 Not valid · 13 Not checked · 69 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This finding is contrary to our recent report in a similar cohort of healthy individuals (1)”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > DISCUSSION
What the sources say
- Partly supportedcites [1] Saad, 2012, Diurnal pattern to insulin secretion and insulin action in healthy individuals, Diabetes sourceExperimental — accuracy not yet measured
Saad et al. 2012 do report a group-level diurnal pattern of postprandial insulin action in 20 healthy volunteers (RESULTS, 'Indices of insulin action': Si higher at breakfast than lunch and dinner, P < 0.05; Abstract: 'insulin sensitivity tended to be higher (P < 0.01) at breakfast than at lunch or dinner'), which supports the citing sentence's attribution of a recent healthy-cohort report of diurnal Si. However, the source does not describe that pattern as uniform: the Discussion states Si only 'tended to be greater' at breakfast with statistical significance versus dinner lost in the log-transformed sensitivity analysis (P = 0.08), and both the Results ('Si and DI distribution', Fig. 5) and Discussion document marked individual heterogeneity, with the high-low-low pattern not maintained in 5 of 20 subjects. The Discussion also explicitly cautions that the study did not test repeatability and that 'we cannot draw any conclusions regarding existence of a true circadian pattern to insulin secretion or action.' Thus the 'contrary to ... a uniform diurnal pattern of postprandial SI' framing overstates what this source claims; the part not supported is the uniformity/definitiveness of the Si pattern in the healthy cohort. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“There were no differences in meal glucose appearance or in glucose disappearance between meals.”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > Abstract
plainn = 19- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“insulin concentration was higher (P < 0.01) and endogenous glucose production less suppressed (P < 0.049) at breakfast than at lunch.”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > Abstract
plainn = 19- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Preprandial baseline glucagon concentrations was lower at breakfast than at lunch (P = 0.023) or dinner (P = 0.013).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Glucose, insulin, and glucagon concentrations.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“SI, either on its natural scale or on its natural log (ln)-transformed scale, did not differ among the three labeled meals (Fig. 3A–C and Table 2).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Insulin action.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
35 more claims
Create a free account to see all 87 claims and to verify the 20 references still open.
- Probably not a substantial claim. 25
- It may state two separate claims as one. 28
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, use of the meal minimal model in conjunction with the triple tracer method permits robust model assessments of indices of insulin action on the periphery (SI) and on the liver (SIL), glucose effectiveness (SG), insulin secretion, and β-cell function (disposition index).[49][50][51][52][53][54][55][56][57][58][59][60][61]”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [55]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The choice to include glucagon secretion was based on our recent data in T1DM 23 showing a nonnegligible glucagon secretion.”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [23]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These updates were based on emerging physiological data related to diurnal patterns of insulin sensitivity, dawn phenomenon, and glucagon effects amongst others.55,[70][71][72]”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [55]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Unfortunately, such a characteristic was proven to not occur in real life.3”
From The university of Virginia/Padova type 1 diabetes simulator matches the glucose traces of a clinical trial (2014) · cites this paper as [3]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“However, it is important to stress that the simulator is not designed to do prospective studies on a given individual, given the large intrasubject variability of real life.”
From The university of Virginia/Padova type 1 diabetes simulator matches the glucose traces of a clinical trial (2014) · cites this paper as [3]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Meal appearance, EGP, and glucose disappearance.
“The integrated rates of EGP were lower at breakfast than at lunch at baseline (P = 0.02) and with the iAUC (P = 0.049).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > DISCUSSION
“Although this could, at least in part, explain the higher rates of EGP in both groups at breakfast than at lunch, it does not explain per se the difference in SI patterns between healthy and type 1 diabetic subjects.”
Citations
Cites
Littell, R. C., Milliken, G. A., Stroup, W. W., Wolfinger, R. D., & Schabenberger, O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,924
Applied Mixed Models in Medicine
Brown, H., & Presco, R. (2000) · Technometrics · doi:10.1080/00401706.2000.10485742 · Cited by 1,262 · cited 2×
“ferences averaged over study periods with the methodology of Brown and Prescott (16).”
MethodSlow-wave sleep and the risk of type 2 diabetes in humans
Tasali, E., Leproult, R., Ehrmann, D. A., & Van Cauter, E. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706446105 · Cited by 921 · cited 1×
“Furthermore, modulation of diurnal patterns of SI by sleep architecture (31,32) could be a player and deserves further investigation.”
BackgroundCross-Over Trials in Clinical Research
(1994) · Technometrics · doi:10.1080/00401706.1994.10485798 · Cited by 763
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · cited 1×
“This observation that SI varies in a subject-specific fashion is an important finding and will be incorporated into the type 1 diabetes simulator (33,34) to allow more reliable testing of closed-loop control algorithms.”
Self-citationBouatia-Naji, N., Bonnefond, A., Cavalcanti-Proença, C., Sparsø, T., Holmkvist, J., Marchand, M., Delplanque, J., Lobbens, S., Rocheleau, G., Durand, E., et al. (2009) · Nature Genetics · doi:10.1038/ng.277 · Cited by 611 · cited 1×
“Therefore, although associations of cortisol and melatonin concentrations to insulin action have been reported in the literature (29,30), we did not find such a link in the present study.”
BackgroundDiurnal pattern to insulin secretion and insulin action in healthy individuals
Saad, A., Dalla Man, C., Nandy, D. K., Levine, J. A., Bharucha, A. E., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., Kudva, Y. C., et al. (2012) · Diabetes · doi:10.2337/db11-1478 · Cited by 297 · cited 10×
“In an effort to determine the existence of a diurnal pattern to postprandial glucose tolerance in type 1 diabetic subjects with subcutaneous open loop insulin delivery, we carefully accounted for confounding factors by controlling for size, calorie content, and composition of all meals as well as for physical activity…”
BackgroundMethodResultSelf-citationClinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
The oral glucose minimal model: Estimation of insulin sensitivity from a meal test
Della Man, C., Caumo, A., & Cobelli, C. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995680 · Cited by 241 · cited 1×
“The oral glucose minimal model (14,15) was used to interpret plasma glucose and insulin concentrations measured during the meal test.”
MethodSelf-citationCircadian modulation of glucose and insulin responses to meals: relationship to cortisol rhythm
Van Cauter, E., Shapiro, E. T., Tillil, H., & Polonsky, K. S. (1992) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1992.262.4.e467 · Cited by 240
Cited by
Items 101–144 of 144
Alternative Frameworks for Personalized Insulin–Glucose Models
Kirchsteiger, H., Efendic, H., Reiterer, F., & del Re, L. (2015) · Lecture notes in bioengineering · doi:10.1007/978-3-319-25913-0_1 · Cited by 3
Schiavon, M., Man, C. D., & Cobelli, C. (2019) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2019.8814915 · Cited by 3
“glucose variability observed in clinical data [1].”
BackgroundSelf-citationNew Contributions Towards Meal and Exercise Announcement-Free Artificial Pancreas Systems
Sala-Mira, I. (2023) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/192684 · Cited by 3
ROMERES, D., RUCHI, F., Breton, M. D., Basu, A., & DeBoer, M. D. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae585 · Cited by 2
Self-citationPostprandial Glucagon Metabolism in Healthy and Type 1 Diabetes
RUCHI, F., Schiavon, M., Pandey, A., Man, C. D., Cobelli, C., Basu, R., & Basu, A. (2025) · Diabetes · doi:10.2337/db25-0587 · Cited by 2
Self-citationMPC-based artificial pancreas accounting for circadian variability of insulin sensitivity
Abuin, P., Ferramosca, A., & González, A. H. (2022) · International Conference on Systems and Control (ICSC) · doi:10.1109/icsc57768.2022.9993915 · Cited by 2
“[4] did not find such a link, and argues that the modulation of diurnal SI patterns could be more related to sleep architecture.”
BackgroundWen, S., Li, H., & Yang, Y. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107204 · Cited by 2
RUCHI, F., Schiavon, M., YADAV, Y. R., Man, C. D., Cobelli, C., Pandey, A., Wilkins, L. R., Basu, R., & Basu, A. (2025) · Diabetes · doi:10.2337/db24-1064 · Cited by 2
Self-citationLuk, A. O. Y., Kong, A. P. S., & Basu, A. (2020) · Diabetic Medicine · doi:10.1111/dme.14335 · Cited by 2
Self-citationGriva, L. O., & BASUALDO, M. S. (2021) · Workshop on Information Processing and Control · doi:10.1109/rpic53795.2021.9648525 · Cited by 2
Personalized Dose Guidance using Safe Bayesian OptimizationPreprint
Krishnamoorthy, D., & Doyle, F. J. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2210.16944 · Cited by 2
A Minimal Model for Type-1 DM Patients: Meal and Exercise Adaptation
Chandrasekhar, A., & Padhi, R. (2024) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2024.05.009 · Cited by 1
Morrison, D., Lee, M. H., Vogrin, S., Hennessy, D., Netzer, E., Jones, H. M., Robinson, L., Smart, C. E., Kurtz, N., Roy, A., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251362500 · Cited by 1
Wen, S., Li, H., & Tao, R. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02866-3 · Cited by 1
Advanced hybrid closed loop (artificial pancreas) and carbohydrate count in type 1 diabetes
Pollakova, D., Pantano, A. L., Folco, U. D., Nardone, M. R., & Tubili, C. (2024) · Mediterranean Journal of Nutrition and Metabolism · doi:10.3233/mnm-230125 · Cited by 1
“It may be due to the different insulin sensitivity in the morning observed in T1D patients [30] and due to the higher carbohydrate load with lower glycemic index of breakfast according to the Italian eating habits (milk, biscuits, oven-baked food) which may require a longer adaptation period of the…”
STOCHASTIC SEASONAL MODELS FOR GLUCOSE PREDICTION IN TYPE 1 DIABETES
Montaser, E. (2020) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/136574 · Cited by 1
Giordanengo, A. (2020) · NORA - Norwegian Open Research Archives · Cited by 1
Forecasting and decision support for type 1 diabetes insulin therapy using machine learning
Castillo, S. O. (2019) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
Advanced insulin dosing algorithms for improving glycemic control in type 1 diabetes
El Fathi, A. (2020) · eScholarship@McGill (McGill) · doi:10.82308/2006 · Cited by 1
Mansell, E. C. (2017) · UC Research Repository (University of Canterbury) · doi:10.26021/2943
Selection of glucose metabolism models with an observer error metric
Misgeld, B. J. E., Schneuing, A., & Leonhardt, S. K. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.11.627
Towards an additive manufactured macroencapsulation device for islet cell replacement therapy
Levey, R. E. (2020) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17353
Faff, J., Bak, W., & Borkowska, G. (1977) · PubMed
Cappon, G. (2019) · Padua@research (University of Padova)
Modeling the Acute Effects of Exercise on Insulin-Glucose Dynamics
Frank, S. (2017) · eScholarship (California Digital Library)
Reza, S. (2023) · International journal of bone marrow research. · doi:10.29328/journal.ijbmr.1001016
Analytical Basal-State Model of the Glucose, Insulin, and C-Peptide Systems for Type 2 Diabetes
Chichester, C. O., Yamakuchi, M., Takenouchi, K., Hashiguchi, T., & Maywar, D. N. (2025) · Bioengineering · doi:10.3390/bioengineering12050553
Krutkyte, G., Banholzer, N., Herzig, D., & Bally, L. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0248
“…likely attributable to both the prolonged “ dawn phenomenon, ” characterized by reduced hepatic insulin sensitivity upon awakening, common in diabetes, 14 – 16 and lower preprandial insulin on board after an overnight fast, reducing the AID system ’ s capability to mitigate breakfast glucose peaks.”
Personalized Meal Bolus Calculator for Type-1 Diabetes Accounting for Diurnal Effects
Krishnamoorthy, D., & Doyle, F. J. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.06.023
Renuse, S., Benson, L. M., Vanderboom, P. M., RUCHI, F., Yadav, Y. R., Johnson, K. L., Brown, B. C., Peterson, J. A., Basu, R., McCormick, D., et al. (2022) · Figshare · doi:10.6084/m9.figshare.19802413
Self-citationReinforcement Learning-Based Decision Support Systems for Individuals with Type 1 Diabetes
Jafar, A. (2023) · eScholarship@McGill (McGill) · doi:10.82308/18769
A novel fully automated artificial pancreas for Type1 Diabetes
Majdpour, D. (2021) · eScholarship@McGill (McGill) · doi:10.82308/27234
Schauer, D. (2018) · University Library Linz repository (Johannes Kepler Universitat Linz)
Blauw, H. (2021) · Pure Amsterdam UMC
A CGM Based Adaptive Bolus Calculator for Insulin Dosing in Diabetes
Reiterer, F. (2017) · University Library Linz repository (Johannes Kepler Universitat Linz)
Stochastic virtual population in type 1 diabetes
Siket, M., Kovács, L., & Eigner, G. (2026) · PLoS ONE · doi:10.1371/journal.pone.0341034
“Hinshaw et al. [33] reported large variability and opposite observation for the diurnal insulin sensitivity in type 1 diabetes compared to healthy ones.”
Periodic predictor of glucose dynamics in type 1 diabetes patients
Ragni, M., Mongini, P. A., Magni, L., & Toffanin, C. (2026) · IFAC Journal of Systems and Control · doi:10.1016/j.ifacsc.2026.100401
Causal mediation pathways in continuous postprandial glucose monitoring for type 1 diabetes patients
Hilligoss, S., & Qu, A. (2026) · npj Metabolic Health and Disease · doi:10.1038/s44324-026-00127-z
In silico development of a bioelectronic islet-based artificial pancreas
Olçomendy, L. (2021) · theses.fr (ABES) · doi:10.70675/79936eabz2e8az470az8954za69f834cde6d
Data-Driven Personalization of Automated Insulin DeliveryPreprint
Kashani, A., Tavasoli, A., & Shakeri, H. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2606.17004
“This is important in t1d, since insulin needs vary across subjects and within the same subject over time due to meal composition, physical activity, stress, circadian effects, and fluctuations in insulin sensitivity [6], [7].”
A Basal Trajectory-Based Framework for Handling Circadian Variations of Insulin Sensitivity
Abuin, P., Sánchez, I. J. G., Ferramosca, A., Toffanin, C., Magni, L., & González, A. H. (2026) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2026.3705069
“Using the oral glucose minimal model (OGMM), studies show that while healthy subjects typically have higher insulin sensitivity at breakfast than later in the day [12], T1D patients display a more irregular pattern with variability about three times greater [13].”
Pancreas and pancreatic hormones: Insulin dosing behavior and “insulin metrics”
Xue, J., & Chang, X. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-30263-3.00006-3
Evaluating Type-1 Diabetes Digital Twins by Decision QualityPreprint
Li, V., Tucker, O., Hughes, M. S., Prioleau, T., & Tang, S. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.30577
“The right setting differs across patients and changes with physical activity, illness, and time of day [9, 12, 18].”
Metadata
- Authors
- Hinshaw, L., Dalla Man, C., Nandy, D. K., Saad, A., Bharucha, A. E., Levine, J. A., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., Kudva, Y. C., & Basu, A.
- Affiliations
- Mayo Clinic (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- University of Padua (IT)
- Corresponding author
- Basu, Ananda
- ORCID
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2013-06-14
- Volume
- 62
- Issue
- 7
- Pages
- 2223-2229
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- PMC
- PMC3712033
- OpenAlex
- W2118160043
- Cited by
- 125
- References
- 39
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 10 · 2023: 8 · 2022: 8 · 2021: 7 · 2020: 5 · 2019: 11 · 2018: 10 · 2017: 11 · 2016: 11 · 2015: 11 · 2014: 13 · 2013: 6
- FWCI
- 10.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- U.S. Public Health Service (UL1-R000135)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK-DP3 094331, R01DK085516, DK-R01-085561)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, insulin sensitivity, diurnal variation, insulin action, insulin pump therapy, glucose flux, endogenous glucose production, postprandial blood glucose, artificial pancreas, personalized algorithms
- MeSH terms
- Adult, Blood Glucose, C-Peptide, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemic Agents, Insulin, Male, Middle Aged, Motor Activity, Postprandial Period, Insulin Aspart
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.