Diurnal Pattern of Insulin Action in Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index; 5 of the 25 sources its claims cite were checked for support.
Abstract
We recently demonstrated a diurnal pattern to insulin action (i.e., insulin sensitivity [SI]) in healthy individuals with higher SI at breakfast than at dinner. To determine whether such a pattern exists in type 1 diabetes, we studied 19 subjects with C-peptide–negative diabetes (HbA1c 7.1 ± 0.6%) on insulin pump therapy with normal gastric emptying. Identical mixed meals were ingested during breakfast, lunch, and dinner at 0700, 1300, and 1900 h in randomized Latin square of order on 3 consecutive days when measured daily physical activity was equal. The triple tracer technique enabled measurement of glucose fluxes. Insulin was administered according to the customary insulin:carbohydrate ratio for each participant. Although postprandial glucose excursions did not differ among meals, insulin concentration was higher (P < 0.01) and endogenous glucose production less suppressed (P < 0.049) at breakfast than at lunch. There were no differences in meal glucose appearance or in glucose disappearance between meals. Although there was no statistical difference (P = 0.34) in SI between meals in type 1 diabetic subjects, the diurnal pattern of SI taken across the three meals in its entirety differed (P = 0.016) from that of healthy subjects. Although the pattern in healthy subjects showed decreasing SI between breakfast and lunch, the reverse SI pattern was observed in type 1 diabetic subjects. The results suggest that in contrast to healthy subjects, SI diurnal pattern in type 1 diabetes is specific to the individual and cannot be extrapolated to the type 1 diabetic population as a whole, implying that artificial pancreas algorithms may need to be personalized.
Overview
CoChat Summary
TL;DR
In 19 adults with C-peptide–negative type 1 diabetes on insulin pump therapy, postprandial glucose excursions did not differ across identical breakfast, lunch, and dinner meals, but insulin concentration was higher and endogenous glucose production less suppressed at breakfast than at lunch. Although insulin sensitivity (SI) did not differ statistically among meals within the type 1 diabetes group, the diurnal SI pattern across meals differed from healthy subjects, suggesting SI patterns in type 1 diabetes are individual-specific and artificial pancreas algorithms may need personalization.
Key findings
- Postprandial glucose excursions did not differ among meals (iAUC P = 0.15), but insulin iAUC was higher at breakfast than lunch (P = 0.008; breakfast vs. lunch P < 0.01), and EGP iAUC was lower at breakfast than lunch (P = 0.049), indicating less EGP suppression at breakfast despite higher insulin.
- SI did not differ among the three meals in type 1 diabetes (P = 0.34), but the diurnal SI pattern across meals differed from healthy subjects (P = 0.016); SI at breakfast was lower in type 1 diabetes than in healthy subjects (5.1 vs. 11.2 × 10−4 dL/kg/min per μU/mL, P = 0.013).
- Estimated mean SI profiles were 5.1–7.6–7.2 × 10−4 dL/kg/min per μU/mL for breakfast, lunch, and dinner in type 1 diabetes, versus 11.2–7.9–8.1 in healthy subjects.
- Meal glucose appearance and glucose disappearance did not differ among meals; glucagon iAUC was higher at breakfast than at lunch or dinner (P < 0.01). Exploratory cortisol, CBG, and melatonin levels did not differ by diabetes status or explain SI differences.
Methods
- Nineteen subjects with C-peptide–negative type 1 diabetes (HbA1c 7.1 ± 0.6%) on insulin pump therapy with normal gastric emptying ingested identical mixed meals at 0700, 1300, and 1900 h on 3 consecutive days, with meal labeling randomized by Latin square and physical activity controlled.
- The triple tracer technique ([6,6-2H2] glucose, [1-13C] glucose-labeled meal, [6-3H] glucose) measured postprandial glucose fluxes; the oral glucose minimal model estimated SI.
- Statistical analysis used SAS PROC MIXED for a three-treatment, three-period crossover design, with a meal-by-diabetes-status interaction comparing type 1 diabetes with healthy subjects.
Limitations
- Stated: the highly structured protocol restricts generalizability; the original sample size anticipated an SD for ln SI of 0.36 and a difference of 0.6 between meals, but observed SDs were 0.89, 0.59, and 1.04 for breakfast, lunch, and dinner, reducing a priori power and increasing type II error risk; larger samples could have shown differences in EGP or SI.
- Stated: the hormone analysis was exploratory and unplanned, using stored samples from only 15 type 1 diabetic and 14 healthy subjects.
- Evident from the text: the study enrolled only 19 type 1 diabetic subjects, and the statistical test for carryover for insulin iAUC had P = 0.04, though no adjustment was implemented per Senn.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
4 Valid · 1 Not valid · 13 Not checked · 69 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This finding is contrary to our recent report in a similar cohort of healthy individuals (1)”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > DISCUSSION
What the sources say
- Partly supportedcites [1] Saad, 2012, Diurnal pattern to insulin secretion and insulin action in healthy individuals, Diabetes sourceExperimental — accuracy not yet measured
Saad et al. 2012 do report a group-level diurnal pattern of postprandial insulin action in 20 healthy volunteers (RESULTS, 'Indices of insulin action': Si higher at breakfast than lunch and dinner, P < 0.05; Abstract: 'insulin sensitivity tended to be higher (P < 0.01) at breakfast than at lunch or dinner'), which supports the citing sentence's attribution of a recent healthy-cohort report of diurnal Si. However, the source does not describe that pattern as uniform: the Discussion states Si only 'tended to be greater' at breakfast with statistical significance versus dinner lost in the log-transformed sensitivity analysis (P = 0.08), and both the Results ('Si and DI distribution', Fig. 5) and Discussion document marked individual heterogeneity, with the high-low-low pattern not maintained in 5 of 20 subjects. The Discussion also explicitly cautions that the study did not test repeatability and that 'we cannot draw any conclusions regarding existence of a true circadian pattern to insulin secretion or action.' Thus the 'contrary to ... a uniform diurnal pattern of postprandial SI' framing overstates what this source claims; the part not supported is the uniformity/definitiveness of the Si pattern in the healthy cohort. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“There were no differences in meal glucose appearance or in glucose disappearance between meals.”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > Abstract
plainn = 19- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“insulin concentration was higher (P < 0.01) and endogenous glucose production less suppressed (P < 0.049) at breakfast than at lunch.”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > Abstract
plainn = 19- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Preprandial baseline glucagon concentrations was lower at breakfast than at lunch (P = 0.023) or dinner (P = 0.013).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Glucose, insulin, and glucagon concentrations.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“SI, either on its natural scale or on its natural log (ln)-transformed scale, did not differ among the three labeled meals (Fig. 3A–C and Table 2).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Insulin action.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
35 more claims
Create a free account to see all 87 claims and to verify the 20 references still open.
- Probably not a substantial claim. 25
- It may state two separate claims as one. 28
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, use of the meal minimal model in conjunction with the triple tracer method permits robust model assessments of indices of insulin action on the periphery (SI) and on the liver (SIL), glucose effectiveness (SG), insulin secretion, and β-cell function (disposition index).[49][50][51][52][53][54][55][56][57][58][59][60][61]”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [55]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The choice to include glucagon secretion was based on our recent data in T1DM 23 showing a nonnegligible glucagon secretion.”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [23]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These updates were based on emerging physiological data related to diurnal patterns of insulin sensitivity, dawn phenomenon, and glucagon effects amongst others.55,[70][71][72]”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [55]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Unfortunately, such a characteristic was proven to not occur in real life.3”
From The university of Virginia/Padova type 1 diabetes simulator matches the glucose traces of a clinical trial (2014) · cites this paper as [3]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“However, it is important to stress that the simulator is not designed to do prospective studies on a given individual, given the large intrasubject variability of real life.”
From The university of Virginia/Padova type 1 diabetes simulator matches the glucose traces of a clinical trial (2014) · cites this paper as [3]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > RESULTS > Meal appearance, EGP, and glucose disappearance.
“The integrated rates of EGP were lower at breakfast than at lunch at baseline (P = 0.02) and with the iAUC (P = 0.049).”
§ Diurnal Pattern of Insulin Action in Type 1 Diabetes > DISCUSSION
“Although this could, at least in part, explain the higher rates of EGP in both groups at breakfast than at lunch, it does not explain per se the difference in SI patterns between healthy and type 1 diabetic subjects.”
Citations
Cites
Littell, R. C., Milliken, G. A., Stroup, W. W., Wolfinger, R. D., & Schabenberger, O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,924
Applied Mixed Models in Medicine
Brown, H., & Presco, R. (2000) · Technometrics · doi:10.1080/00401706.2000.10485742 · Cited by 1,262 · cited 2×
“ferences averaged over study periods with the methodology of Brown and Prescott (16).”
MethodSlow-wave sleep and the risk of type 2 diabetes in humans
Tasali, E., Leproult, R., Ehrmann, D. A., & Van Cauter, E. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706446105 · Cited by 921 · cited 1×
“Furthermore, modulation of diurnal patterns of SI by sleep architecture (31,32) could be a player and deserves further investigation.”
BackgroundCross-Over Trials in Clinical Research
(1994) · Technometrics · doi:10.1080/00401706.1994.10485798 · Cited by 763
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · cited 1×
“This observation that SI varies in a subject-specific fashion is an important finding and will be incorporated into the type 1 diabetes simulator (33,34) to allow more reliable testing of closed-loop control algorithms.”
Self-citationBouatia-Naji, N., Bonnefond, A., Cavalcanti-Proença, C., Sparsø, T., Holmkvist, J., Marchand, M., Delplanque, J., Lobbens, S., Rocheleau, G., Durand, E., et al. (2009) · Nature Genetics · doi:10.1038/ng.277 · Cited by 611 · cited 1×
“Therefore, although associations of cortisol and melatonin concentrations to insulin action have been reported in the literature (29,30), we did not find such a link in the present study.”
BackgroundDiurnal pattern to insulin secretion and insulin action in healthy individuals
Saad, A., Dalla Man, C., Nandy, D. K., Levine, J. A., Bharucha, A. E., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., Kudva, Y. C., et al. (2012) · Diabetes · doi:10.2337/db11-1478 · Cited by 297 · cited 10×
“In an effort to determine the existence of a diurnal pattern to postprandial glucose tolerance in type 1 diabetic subjects with subcutaneous open loop insulin delivery, we carefully accounted for confounding factors by controlling for size, calorie content, and composition of all meals as well as for physical activity…”
BackgroundMethodResultSelf-citationClinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
The oral glucose minimal model: Estimation of insulin sensitivity from a meal test
Della Man, C., Caumo, A., & Cobelli, C. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995680 · Cited by 241 · cited 1×
“The oral glucose minimal model (14,15) was used to interpret plasma glucose and insulin concentrations measured during the meal test.”
MethodSelf-citationCircadian modulation of glucose and insulin responses to meals: relationship to cortisol rhythm
Van Cauter, E., Shapiro, E. T., Tillil, H., & Polonsky, K. S. (1992) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1992.262.4.e467 · Cited by 240
Cited by
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Self-citationThe UVA/Padova Type 1 Diabetes Simulator Goes From Single Meal to Single Day
Visentin, R., Campos-Náñez, E., Schiavon, M., Lv, D., Vettoretti, M., Breton, M., Kovatchev, B. P., Dalla Man, C., & Cobelli, C. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818757747 · Cited by 280
“In silico CR values at breakfast are lower than those at lunch and dinner within each cohort, in agreement with Hinshaw et al.27 The distributions of CR at breakfast, lunch, and dinner, together with that of CF in the three populations are also shown in Figure 3.”
ResultSelf-citationCobelli, C., Dalla Man, C., Toffolo, G., Basu, R., Vella, A., & Rizza, R. (2014) · Diabetes · doi:10.2337/db13-1198 · Cited by 216
“For instance, the battery of oral glucose, C-peptide, and insulin models has been used to study the effect of age and sex on glucose metabolism (8), the effect of antiaging drugs (35), the influence of ethnicity (36), SI and b-cell function in nondiabetic (37) and obese (38) adolescents and children (39), the pathogen…”
MethodSelf-citationTime Lag of Glucose From Intravascular to Interstitial Compartment in Humans
Basu, A., Dube, S., Slama, M., Errazuriz, I., Amezcua, J. C., Kudva, Y. C., Peyser, T., Carter, R. E., Cobelli, C., & Basu, R. (2013) · Diabetes · doi:10.2337/db13-1132 · Cited by 205
“[3-(3)H] glucose counts were analyzed as previously described (15).”
MethodSelf-citationThe Artificial Pancreas: How Closed-Loop Control Is Revolutionizing Diabetes
Haidar, A. (2016) · IEEE Control Systems · doi:10.1109/mcs.2016.2584318 · Cited by 164
Toward a Run-to-Run Adaptive Artificial Pancreas: In Silico Results
Toffanin, C., Visentin, R., Messori, M., Palma, F. D., Magni, L., & Cobelli, C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2652062 · Cited by 107
“A recent study was conducted on T1DM subjects, who underwent a mixed meal with triple tracer approach at breakfast (B), lunch (L), and dinner (D), with all meals having same amount and composition [32].”
BackgroundSelf-citationCircadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113
“More details on the study protocol can be found in Hinshaw et al.(16) Figure 1A shows the average SI at B, L, and D reported by Hinshaw et al.”
InfluentialSelf-citationGingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
Song, S., & Roy, S. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25895 · Cited by 108
“Although use of insulin injections and insulin pumps are lifeprolonging technologies, they do not mimic real-time secretory patterns of pancreatic b cells nor do they prevent long-term complications (Hinshaw et al., 2013; Penfornis et al., 2011).”
BackgroundVisentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103
Self-citationExercise effects on postprandial glucose metabolism in type 1 diabetes: a triple-tracer approach
Mallad, A., Hinshaw, L., Schiavon, M., Dalla Man, C., Dadlani, V., Basu, R., Lingineni, R., Cobelli, C., Johnson, M. L., Carter, R., et al. (2015) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00014.2015 · Cited by 94
Self-citationClosed-Loop Artificial Pancreas Systems: Physiological Input to Enhance Next-Generation Devices
Kudva, Y. C., Carter, R. E., Cobelli, C., Basu, R., & Basu, A. (2014) · Diabetes Care · doi:10.2337/dc13-2066 · Cited by 83
“Using a triple tracer technique (14), the existence of a diurnal pattern of SI in T1D that differs from healthy nondiabetic subjects (15) has recently been reported (16).”
BackgroundSelf-citationToghi-Eshghi, S. R., & Yardley, J. E. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-02384 · Cited by 93
Fathi, A. E., Smaoui, M. R., Gingras, V., Boulet, B., & Haidar, A. (2018) · IEEE Control Systems · doi:10.1109/mcs.2017.2766323 · Cited by 92
Contreras, I., Oviedo, S., Vettoretti, M., Visentin, R., & Vehí, J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0187754 · Cited by 80
Visentin, R., Man, C. D., & Cobelli, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2535241 · Cited by 86
“Since in [7], three identical meals (50 g of carbohydrate) were given in order to eliminate confounding effects on the diurnal pattern of insulin sensitivity in the 19 T1DM subjects, we prefer to focus here on the dataset of [8] where the three meals resemble real life breakfast, lunch, and dinner and a much larger nu…”
BackgroundMethodResultSelf-citationDassau, E., Brown, S. A., Basu, A., Pinsker, J. E., Kudva, Y. C., Gondhalekar, R., Patek, S., Lv, D., Schiavon, M., Lee, J. B., et al. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2081 · Cited by 74
Self-citationDynamic Insulin on Board: Incorporation of Circadian Insulin Sensitivity Variation
Toffanin, C., Zisser, H., Doyle, F. J., & Dassau, E. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700415 · Cited by 76
A Review of Safety and Design Requirements of the Artificial Pancreas
Blauw, H., Keith-Hynes, P., Koops, R., & DeVries, J. H. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1679-2 · Cited by 75
Exercise, Hypoglycemia, and Type 1 Diabetes
Basu, R., Johnson, M. L., Kudva, Y. C., & Basu, A. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0097 · Cited by 73
Self-citationSchiavon, M., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2014) · Diabetes Care · doi:10.2337/dc13-1120 · Cited by 64
“The oral glucose minimal model [3][4] was used to estimate insulin sensitivity, from plasma glucose and insulin concentrations, in twelve subjects studied three times [10].”
BackgroundMethodSelf-citationInfante, M., Baidal, D. A., Rickels, M. R., Fabbri, A., Skyler, J. S., Alejandro, R., & Ricordi, C. (2021) · Artificial Organs · doi:10.1111/aor.14023 · Cited by 66
Gingras, V., RABASA-LHORET, R. P. R., Messier, V., Ladouceur, M., Legault, L., & Haidar, A. (2015) · Diabetes & Metabolism · doi:10.1016/j.diabet.2015.05.001 · Cited by 66
Viceconti, M., Cobelli, C., Haddad, T., Himes, A., Kovatchev, B., & Palmer, M. (2017) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411917702931 · Cited by 64
“The simulator domain of validity was then extended by the introduction of diurnal patterns of insulin sensitivity based on data in 19 T1DM subjects who underwent a triple-tracer study.(90) This has allowed the incorporation of a circadian time-varying insulin sensitivity into the simulator, thus making this technology…”
MethodSelf-citationZisser, H., Renard, E., Kovatchev, B., Cobelli, C., Avogaro, A., Nimri, R., Magni, L., Buckingham, B. A., Chase, H. P., Doyle, F. J., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0066 · Cited by 48
Self-citationDeveloping the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Self-citationVISENTIN, R., Cobelli, C., & Man, C. D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0110 · Cited by 44
Self-citationRizza, R. A., Toffolo, G., & Cobelli, C. (2016) · Diabetes · doi:10.2337/db15-1166 · Cited by 42
Self-citationGlucose-responsive insulin delivery for type 1 diabetes: The artificial pancreas story
Bally, L., Thabit, H., & Hovorka, R. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.022 · Cited by 43
King, A. B., Kuroda, A., Matsuhisa, M., & Hobbs, T. M. (2016) · Current Diabetes Reports · doi:10.1007/s11892-016-0772-0 · Cited by 41
Closed loop developments to improve glucose control at home
Renard, É., Cobelli, C., & Kovatchev, B. P. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.09.009 · Cited by 40
Self-citationHinshaw, L., Schiavon, M., Mallad, A., Man, C. D., Basu, R., Bharucha, A. E., Cobelli, C., Carter, R. E., Basu, A., & Kudva, Y. C. (2014) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00199.2014 · Cited by 35
Self-citationEffect of Pramlintide on Postprandial Glucose Fluxes in Type 1 Diabetes
Hinshaw, L., Schiavon, M., Dadlani, V., Mallad, A., Dalla Man, C., Bharucha, A., Basu, R., Geske, J. R., Carter, R. E., Cobelli, C., et al. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3952 · Cited by 32
Self-citationGingras, V., Haidar, A., Messier, V., Legault, L., Ladouceur, M., & RABASA-LHORET, R. P. R. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0043 · Cited by 35
“28 We tested in a previous study the dual-hormone closed-loop system combined with a simplified meal bolus using two meal bolus categories, and we showed amelioration in glycemic control, with, however, greater postmeal excursions after large carbohydrate-content meals.”
HyMn: Mining linear hybrid automata from input output traces of cyber-physical systems
Lamrani, I., Banerjee, A., & Gupta, S. K. S. (2018) · IEEE International Conference on Industrial Cyber-Physical Systems (ICPS) · doi:10.1109/icphys.2018.8387670 · Cited by 35
Using Grammatical Evolution to Generate Short-term Blood Glucose Prediction Models.
Contreras, I., Bertachi, A. H., Biagi, L., Vehí, J., & Oviedo, S. (2018) · International Joint Conference on Artificial Intelligence · Cited by 35
Haidar, A., Farid, D., St‐Yves, A., Messier, V., Chen, V., Xing, D., Brazeau, A., Duval, C., Boulet, B., Legault, L., et al. (2014) · Diabetes & Metabolism · doi:10.1016/j.diabet.2013.12.001 · Cited by 30
Hinshaw, L., Mallad, A., Dalla Man, C., Basu, R., Cobelli, C., Carter, R. E., Kudva, Y. C., & Basu, A. (2015) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00236.2015 · Cited by 28
Self-citationGiordanengo, A., Årsand, E., Woldaregay, A. Z., Bradway, M., Grøttland, A., Hartvigsen, G., Granja, C., Torsvik, T., & Hansen, A. H. (2019) · JMIR Diabetes · doi:10.2196/14002 · Cited by 30
“The calculations presented in the overview table (Figure 4 D) can facilitate diabetes management [57-60] for both patients and clinicians.”
BackgroundDesjardins, K., Brazeau, A., Strychar, I. M., Leroux, C., Gingras, V., & RABASA-LHORET, R. P. R. (2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2014.09.015 · Cited by 29
Majdpour, D., Tsoukas, M. A., Yale, J., Fathi, A. E., Rutkowski, J., René, J., Garfield, N., Legault, L., & Haidar, A. (2021) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2021.02.002 · Cited by 29
Mallad, A., Hinshaw, L., Man, C. D., Cobelli, C., Basu, R., Lingineni, R. K., Carter, R. E., Kudva, Y. C., & Basu, A. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0011 · Cited by 26
Self-citationUsing causality modeling and Fuzzy Lattice Reasoning algorithm for predicting blood glucose
Fong, S. J., Mohammed, S., Fiaidhi, J., & Kwoh, C. K. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.07.035 · Cited by 26
“2(a)); two exceptionally high doses of insulin over units of 100 were given; more importantly the insulin pattern is never periodically exact, although some cycles are seen repeating (Hinshaw et al., 2013).”
BackgroundFathi, A. E., Kearney, R. E., Palisaitis, E., Boulet, B., & Haidar, A. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3023555 · Cited by 25
A comparison among three maximal mathematical models of the glucose-insulin system
Pompa, M., Panunzi, S., Borri, A., & De Gaetano, A. (2021) · PLOS ONE · doi:10.1371/journal.pone.0257789 · Cited by 24
Smith, T. A., Smart, C. E., Howley, P. P., Lopez, P. E., & King, B. R. (2021) · Diabetic Medicine · doi:10.1111/dme.14512 · Cited by 23
Cobelli, C., & Man, C. D. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211015268 · Cited by 24
“169 A future model refinement will include the description of intra-/inter-day variability of key model parameters, similarly to what has been recently done in H and T1D, 63,64 thus improving the simulator reliability on long-term scenarios.”
MethodSelf-citationShedding light on grey noise in diabetes modelling
Mansell, E. J., Docherty, P. D., & Chase, J. G. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.06.007 · Cited by 23
Control-Oriented Model With Intra-Patient Variations for an Artificial Pancreas
Moscoso-Vásquez, M., Colmegna, P. H., Rosales, N., Garelli, F., & Sánchez‐Peña, R. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2969389 · Cited by 23
“were included in the UVA/Padova metabolic simulator [33]–[35] by associating each in-silico subject with one of seven possible variability classes, assigned to a specific time-varying SI profile [5], [36].”
BackgroundMethodSchiavon, M., Man, C. D., & Cobelli, C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0248 · Cited by 23
Self-citationClosed-Loop and Artificial Intelligence–Based Decision Support Systems
Nimri, R., Phillip, M., & Kovatchev, B. P. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.2505 · Cited by 22
Farabi, S. S., Carley, D. W., & Quinn, L. T. (2016) · Biological Research For Nursing · doi:10.1177/1099800416685177 · Cited by 22
“Multiple biological processes exhibit circadian patterns, including insulin sensitivity in individuals with T1DM (Hinshaw et al., 2013; Tatò, Tatò, Beyer, & Schrezenmeir, 1991).”
BackgroundModeling the acute effects of exercise on insulin kinetics in type 1 diabetes
Frank, S., Jbaily, A., Hinshaw, L., Basu, R., Basu, A., & Szeri, A. J. (2018) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-018-9611-z · Cited by 22
Self-citationLi, P., Yu, L., Fang, Q., & Lee, S.-Y. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1436-y · Cited by 22
Paradigm Shifts in Nocturnal Glucose Control in Type 2 Diabetes
Basu, A., Joshi, N., Miles, J., Carter, R. E., Rizza, R. A., & Basu, R. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-00873 · Cited by 22
Self-citationMagkos, F., Reeds, D. N., & Mittendorfer, B. (2022) · Physiological Reviews · doi:10.1152/physrev.00015.2022 · Cited by 21
Bringing closed-loop home: recent advances in closed-loop insulin delivery
Thabit, H., & Hovorka, R. (2014) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000048 · Cited by 20
ARX model for interstitial glucose prediction during and after physical activities
Ugalde, H. M. R., Garnotel, M., Doron, M., Jallon, P., Charpentier, G., Franc, S., Huneker, E., Simon, C., & Bonnet, S. (2019) · Control Engineering Practice · doi:10.1016/j.conengprac.2019.07.013 · Cited by 20
Advanced carbohydrate counting: An engineering perspective
Reiterer, F., & Freckmann, G. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.06.003 · Cited by 19
Hypoglycaemia‐free artificial pancreas project
Magdelaine, N., Rivadeneira, P. S., Chaillous, L., Fournier‐Guilloux, A., Krempf, M., MohammadRidha, T., Ahmed, M. A., & Moog, C. H. (2019) · IET Systems Biology · doi:10.1049/iet-syb.2018.5069 · Cited by 19
“• CF might vary with the time of the day [14], physical activity [15], stress or illness.”
BackgroundInvalidation and low-order model set for artificial pancreas robust control design
Bianchi, F. D., Moscoso-Vásquez, M., Colmegna, P. H., & Sánchez‐Peña, R. (2019) · Journal of Process Control · doi:10.1016/j.jprocont.2019.02.004 · Cited by 17
Automated Insulin Delivery: The Artificial Pancreas Technical Challenges
Hernando, M. E., García-Sáez, G., Aguilera, E. J. G., Gandía, C. P., & Rodríguez-Herrero, A. (2019) · American Journal of Therapeutics · doi:10.1097/mjt.0000000000001086 · Cited by 17
Intra-patient dynamic variations in Type 1 Diabetes: A review
Moscoso-Vásquez, M., Colmegna, P. H., & Sánchez‐Peña, R. (2016) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2016.7587866 · Cited by 16
“Moreover, large inter-subject variability restrains the possibility of defining diurnal patterns in IS that could be extrapolated to the T1DM population as a whole, and thus, artificial pancreas algorithms need to be personalized [39].”
BackgroundEmpirical dynamic model identification for blood-glucose dynamics in response to physical activity
Dasanayake, I., Seborg, D. E., Pinsker, J. E., Doyle, F. J., & Dassau, E. (2015) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2015.7402815 · Cited by 15
“Therefore, those variables are hard to use in dynamical system modeling, especially considering that there is significant day-to-day variability in carbohydrate metabolism in persons with type 1 diabetes [5].”
BackgroundRisk analysis for the design of a safe artificial pancreas control system
Kölle, K., Fougner, A. L., Lundteigen, M. A., Carlsen, S. M., Ellingsen, R., & Stavdahl, Ø. (2018) · Health and Technology · doi:10.1007/s12553-018-0269-8 · Cited by 15
Meal detection based on non-individualized moving horizon estimation and classification
Kölle, K., Fougner, A. L., & Stavdahl, Ø. (2017) · IEEE Conference on Control Technology and Applications (CCTA) · doi:10.1109/ccta.2017.8062516 · Cited by 13
“The model has originally been developed to describe the glucoseinsulin dynamics during an intravenous glucose tolerance test and has later been used to determine insulin sensitivities during oral glucose loads [15], [16], [17].”
MethodAn Expert Opinion on Advanced Insulin Pump Use in Youth with Type 1 Diabetes
Bode, B. W., KAUFMAN, F. R., & Vint, N. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0354 · Cited by 12
Priming Effect of a Morning Meal on Hepatic Glucose Disposition Later in the Day
Moore, M. C., Smith, M. S., Farmer, B., Kraft, G., Shiota, M., Williams, P. E., & Cherrington, A. D. (2017) · Diabetes · doi:10.2337/db16-1308 · Cited by 11
Jafar, A., & Pasqua, M. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15463 · Cited by 11
YADAV, Y. R., ROMERES, D., Cobelli, C., Man, C. D., Carter, R. E., Basu, A., & Basu, R. (2022) · Diabetes · doi:10.2337/db22-0238 · Cited by 11
Self-citationIdentification of diurnal patterns in insulin action from measured CGM data for patients with T1DM
Reiterer, F., Kirchsteiger, H., Freckmann, G., & del Re, L. (2015) · European Control Conference (ECC) · doi:10.1109/ecc.2015.7330516 · Cited by 11
“The results in [12] suggested that there was no universal pattern for the insulin sensitivity SI as a function of daytime that looks the same for all patients, but there is rather a patientspecific profile.”
BackgroundResultMetabolic Models, in Silico Trials, and Algorithms
Çınar, A., Basu, A., Bequette, B. W., Breton, M. D., Buckingham, B. A., Cengiz, E., Cobelli, C., Dassau, E., Doyle, F. J., Fabris, C., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251338300 · Cited by 10
Self-citationEstimation of insulin sensitivity in diabetic Göttingen Minipigs
Misgeld, B. J. E., Tenbrock, P. G., Lunze, K., Dietrich, J. W., & Leonhardt, S. K. (2016) · Control Engineering Practice · doi:10.1016/j.conengprac.2016.06.004 · Cited by 10
Physiological models for artificial pancreas development
VISENTIN, R., Schiavon, M., Basu, R., Basu, A., Man, C. D., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00015-6 · Cited by 10
Self-citationTaylor, G., Shaw, A., Smith, K., Wason, J. M. S., McDonald, T. J., Oram, R. A., Stevenson, E., Shaw, J., & West, D. J. (2022) · Diabetic Medicine · doi:10.1111/dme.14814 · Cited by 10
What’s the Time? Does the Artificial Pancreas Need to Know?
Stenvers, D. J., DeVries, J. H., & la Fleur, S. E. (2013) · Diabetes · doi:10.2337/db13-0466 · Cited by 10
Gingras, V., Smaoui, M. R., Cameli, C., Messier, V., Ladouceur, M., Legault, L., & RABASA-LHORET, R. P. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-20785-4 · Cited by 10
Renuse, S., Benson, L. M., Vanderboom, P. M., RUCHI, F., YADAV, Y. R., Johnson, K. L., Brown, B. C., Peterson, J. A., Basu, R., McCormick, D., et al. (2022) · Clinical Proteomics · doi:10.1186/s12014-022-09344-2 · Cited by 9
“In addition, there is inadequate plasma glucagon concentration in response to declining plasma glucose levels in the late post-prandial period increasing the risk for and delayed recovery from hypoglycemia [1, 4].”
BackgroundSelf-citationSchiavon, M., Galderisi, A., Basu, A., Kudva, Y. C., Cengiz, E., & Dalla Man, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0397 · Cited by 8
“…insulin therapy parameters, like CR, in real life condition of individuals with T1D, one should manage the within-and between-day variability in S I.32,33 As an example, one can iteratively update S I and CR estimates, let say every week, using a run-to-run approach, as done in, 16 where the…”
Self-citationAbuin, P., Ferramosca, A., Toffanin, C., Magni, L., & González, A. H. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.09.023 · Cited by 8
Blood glucose prediction for type 2 diabetes using clustering-based domain adaptation
Yang, T., Yu, X., Tao, R., Li, H., & Zhou, J. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107629 · Cited by 8
A novel natural tracer method to measure complex carbohydrate metabolism
Basu, R., Schiavon, M., Petterson, X.-M. T., Hinshaw, L., Slama, M. Q., Carter, R. E., Man, C. D., Cobelli, C., & Basu, A. (2019) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00133.2019 · Cited by 8
Self-citationGlucose Rate-of-Change and Insulin-on-Board Jointly Weighted Zone Model Predictive Control
Deshpande, S., Doyle, F. J., & Dassau, E. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3291573 · Cited by 7
“in insulin sensitivity from circadian dynamics [6], [7] or”
BackgroundDu, S., Wu, H., Xu, X., Meng, Y., Xia, F., Zhai, H., & Lu, Y. (2014) · Journal of Diabetes Research · doi:10.1155/2014/743798 · Cited by 7
“2 ] glucose injected with a minute amount to trace the natural fasting glucose fluxes without influence plasma glucose concentration is a classical approach to research glucose mechanism in animals and humans in vivo [16, 17, 21, 22].”
BackgroundModelado y simulación de tecnologías para el tratamiento de la diabetes
Rosales, N. (2020) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/97299 · Cited by 7
Moscoso-Vásquez, M., Fabris, C., & Breton, M. D. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231206798 · Cited by 6
“These ranges are consistent with intrasubject IS variation observed in the results of mixed meal glucose tolerance tests reported by Hinshaw et al. 38”
ResultAdaptive Biobehavioral Control: A Pilot Analysis of Human–Machine Coadaptation in Type 1 Diabetes
Colmegna, P. H., McFadden, R. K., Fabris, C., Lobo, B. J., Nass, R. M., Oliveri, M. C., Brown, S. A., & Kovatchev, B. P. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0399 · Cited by 6
Eto, T., Haranaka, M., Kristensen, N. R., Navarria, A., Nishida, T., Ribel‐Madsen, R., Søgaard, S. B., & Halberg, I. B. (2024) · Journal of Diabetes Investigation · doi:10.1111/jdi.14384 · Cited by 6
Griggs, S. A., Barbato, E. S., Hernández, E., Gupta, D., Margevicius, S. P., Grey, M. J., & Hickman, R. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-09728-2 · Cited by 6
A Five-Step Strategy to Combine Data Sources from Multiple Wearable Sensors
Levine, J. A. (2017) · Technology and Investment · doi:10.4236/ti.2017.81003 · Cited by 6
“Conversely, if a patient eats too much their insulin dose may be inadequate and they become hyperglycemic (high blood glucose) [14].”
BackgroundSelf-citationSparse Reconstruction of Glucose Fluxes Using Continuous Glucose Monitors
Al-Matouq, A., Laleg‐Kirati, T., Novara, C., Rabbone, I., & Vincent, T. L. (2019) · IEEE Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2019.2905198 · Cited by 6
Metabolic Models, in Silico Trials, and Algorithms
Çınar, A., Basu, A., Bequette, B. W., Breton, M. D., Buckingham, B. A., Cengiz, E., Cobelli, C., Dassau, E., Doyle, F. J., Fabris, C., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.18800.ac · Cited by 5
Self-citationClosed-loop MPC-based artificial pancreas: Handling circadian variability of insulin sensitivity
Abuin, P., Sereno, J. E., Ferramosca, A., & González, A. H. (2020) · Argentine Conference on Automatic Control (AADECA) · doi:10.23919/aadeca49780.2020.9301636 · Cited by 5
“Besides, circadian variability (24-h) of insulin sensitivity (SI ) is well known phenomenon that occurs in T1DM subjects, characterized by a periodic insulin sensitivity insulin pattern, being lower, on average, at breakfast than lunch and dinner [4].”
BackgroundReduced-order filtering for insulin sensitivity estimation under external disturbances
Misgeld, B. J. E., Tenbrock, P. G., & Leonhardt, S. K. (2017) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2017.7963156 · Cited by 5
“An important parameter that varies over time in diurnal manner is the insulin sensitivity [7].”
BackgroundGreenwood, N., & Gunton, J. E. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814536271 · Cited by 5
Kastrati, L., Álvarez‐Martínez, M., Thomas, A., Thevis, M., Muka, T., Stettler, C., Herzig, D., Glišić, M., & Bally, L. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16088 · Cited by 4
Insulin:Carbohydrate Ratio—Part of the Story
Basu, A., & Basu, R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0333 · Cited by 4
Self-citationDiabète de type 1 du modèle ... à la boucle fermée
Magdelaine, N. (2017) · theses.fr (ABES) · doi:10.70675/abaad835z8c10z4e88z8e21z1c1b6b3604e1 · Cited by 4
Waterman, H. L., Moore, M. C., Smith, M. S., Farmer, B., Yankey, K. C., Scott, M. F., Edgerton, D. S., & Cherrington, A. D. (2024) · Diabetes · doi:10.2337/db24-0786 · Cited by 3
POGO: A Method for individualization of Automated Insulin Delivery Systems
Pryor, E. C., Moscoso-Vásquez, M., & Breton, M. D. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.06.008 · Cited by 3
Metadata
- Authors
- Hinshaw, L., Dalla Man, C., Nandy, D. K., Saad, A., Bharucha, A. E., Levine, J. A., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., Kudva, Y. C., & Basu, A.
- Affiliations
- Mayo Clinic (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- University of Padua (IT)
- Corresponding author
- Basu, Ananda
- ORCID
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2013-06-14
- Volume
- 62
- Issue
- 7
- Pages
- 2223-2229
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- PMC
- PMC3712033
- OpenAlex
- W2118160043
- Cited by
- 125
- References
- 39
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 10 · 2023: 8 · 2022: 8 · 2021: 7 · 2020: 5 · 2019: 11 · 2018: 10 · 2017: 11 · 2016: 11 · 2015: 11 · 2014: 13 · 2013: 6
- FWCI
- 10.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- U.S. Public Health Service (UL1-R000135)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK-DP3 094331, R01DK085516, DK-R01-085561)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, insulin sensitivity, diurnal variation, insulin action, insulin pump therapy, glucose flux, endogenous glucose production, postprandial blood glucose, artificial pancreas, personalized algorithms
- MeSH terms
- Adult, Blood Glucose, C-Peptide, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemic Agents, Insulin, Male, Middle Aged, Motor Activity, Postprandial Period, Insulin Aspart
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.