Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 242

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

1,5-Anhydroglucitol and Postprandial Hyperglycemia as Measured by Continuous Glucose Monitoring System in Moderately Controlled Patients With Diabetes

Open access
Dungan, Kathleen M., Buse, John B., Largay, Joseph, Kelly, Mary M., Button, Eric A., Kato, Shuhei, Wittlin, Steven · 2006 · Diabetes Care

Abstract

OBJECTIVE—Postprandial hyperglycemia is often inadequately assessed in diabetes management. Serum 1,5-anhydroglucitol (1,5-AG) drops as serum glucose rises above the renal threshold for glucose and has been proposed as a marker for postprandial hyperglycemia. The objective of this study is to demonstrate the relationship between 1,5-AG and postprandial hyperglycemia, as assessed by the continuous glucose monitoring system (CGMS) in suboptimally controlled patients with diabetes. RESEARCH DESIGN AND METHODS—Patients with type 1 or type 2 diabetes and an HbA1c (A1C) between 6.5 and 8% with stable glycemic control were recruited from two sites. A CGMS monitor was worn for two consecutive 72-h periods. Mean glucose, mean postmeal maximum glucose (MPMG), and area under the curve for glucose above 180 mg/dl (AUC-180), were compared with 1,5-AG, fructosamine (FA), and A1C at baseline, day 4, and day 7. RESULTS—1,5-AG varied considerably between patients (6.5 ± 3.2 μg/ml [means ± SD]) despite similar A1C (7.3 ± 0.5%). Mean 1,5-AG (r = −0.45, P = 0.006) correlated with AUC-180 more robustly than A1C (r = 0.33, P = 0.057) or FA (r = 0.38, P = 0.88). MPMG correlated more strongly with 1,5-AG (r = −0.54, P = 0.004) than with A1C (r = 0.40, P = 0.03) or FA (r = 0.32, P = 0.07). CONCLUSIONS—1,5-AG reflects glycemic excursions, often in the postprandial state, more robustly than A1C or FA. 1,5-AG may be useful as a complementary marker to A1C to assess glycemic control in moderately controlled patients with diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc06-1910

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 242

Metadata

Authors
Dungan, K. M., Buse, J. B., Largay, J., Kelly, M. M., Button, E. A., Kato, S., & Wittlin, S.
Venue
Diabetes Care
Published
2006-06-01
Volume
29
Issue
6
Pages
1214-1219
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2144384987
Cited by
242
References
5
FWCI
5.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 1,5-Anhydroglucitol and Postprandial Hyperglycemia as Measured by Continuous Glucose Monitoring System in Moderately Controlled Patients With Diabetes. https://app.cochat.ai/papers/10.2337/dc06-1910
The paper
Dungan, K. M., Buse, J. B., Largay, J., Kelly, M. M., Button, E. A., Kato, S., & Wittlin, S. (2006). 1,5-Anhydroglucitol and Postprandial Hyperglycemia as Measured by Continuous Glucose Monitoring System in Moderately Controlled Patients With Diabetes. Diabetes Care. https://doi.org/10.2337/dc06-1910

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.